Stent LEV2517-PMARecalls & reported problems
Microvention, Inc. · LVIS EVO · Class 3 · Implant
All models of Stent (63)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00842429117750), received between Jan 10, 2024 and Jun 7, 2026 — classified as 2 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Retraction Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Retraction Problem3
- Adverse Event Without Identified Device or Use Problem1
- Device Stenosis1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Thrombosis/Thrombus1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryJun 7, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THROUGH A CAR REGISTRY STUDY THAT THE SUBJECT EXPERIENCED A BLISTER ANEURYSM. AN ATTEMPT WAS MADE TO TREAT THE ANEURYSM BY COILING, AND THEN AFTER THE COILS KEPT FALLING OUT DUE TO THE ANEURYSM TYPE. THE PHYSICIAN THEN PLACED AN LVIS STENT TO CONDUCT STENT ASSISTED COILING TO TREAT THE ANEURYSM. AT 31 DAYS POST PROCEDURE, FLUOROSCOPIC IMAGING REVEALED THE DEVELOPMENT OF IN STENT STENOSIS. THIS COMPLICATION WAS TREATED WITH A THROMBECTOMY. THE OUTCOME WAS RESOLVED. IT WAS NOTED: EVENT NUMBER: 1 ADVERSE EVENT TERM: IN STENT PARTIAL OCCLUSION RELATIONSHIP TO STUDY DEVICE: RELATED RELATIONSHIP TO INDEX ENDOVASCULAR PROCEDURE: DEFINITELY RELATED RELATIONSHIP TO USE OF ANCILLARY DEVICE: NOT RELATED RELATIONSHIP TO STUDY DISEASE: NOT RELATED RELATIONSHIP TO CONCURRENT DISEASE: NOT RELATED RELATIONSHIP TO DUAL ANTIPLATELET THERAPY: NOT RELATED. PLEASE NOTE THAT THE COILS USED TO TREAT THE BLISTERING ANEURYSM ARE CONSIDERED NOT RELATED TO THE STUDY DEVICE. THEY ARE CONSIDERED ANCILLARY DEVICES USED IN THIS CASE. THE STENT USED IN THIS CASE IS CONSIDERED TO BE RELATED TO THE STUDY DEVICE, LVIS EVO.
Patient problems: Thrombosis/Thrombus
MAUDE report 25422363 ↗InjuryMay 30, 2025Device Stenosis; Device Stenosis
ADDITIONAL INFORMATION WAS RECEIVED STATING THAT THE STENT IMPLANT DATE IS (B)(6) 2024.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22119697 ↗MalfunctionJan 10, 2025Retraction Problem; Retraction Problem
IT WAS REPORTED THAT THE LVIS EVO COULD NOT BE RECAPTURED IN THE MICROCATHETER. STENT / COIL PROCEDURE (ACOMM). A STENT / COIL PROCEDURE WAS PERFORMED TO TREAT AN ACOMM ANEURYSM. THE MICROCATHETER WAS USED IN A "JAILED" TECHNIQUE TO DELIVER LVIS EVO. A SEPARATE MICROCATHETER WAS USED TO DELIVER ONE COIL. WHEN DELIVERING LVIS EVO, PHYSICIAN ATTEMPTED TO RECAPTURE PARTIALLY DEPLOYED (APPROXIMATELY 1/3 TO 1/2) STENT TO REPOSITION THE EVO. THE STENT WOULD NOT RECAPTURE BACK INTO THE MICROCATHETER. STENT WAS DELIVERED DUE TO NOT BEING RECAPTURABLE. THE PATIENT IS DOING WELL AND DISCHARGED FROM THE HOSPITAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21126084 ↗MalfunctionMay 14, 2024Retraction Problem; Retraction Problem
IT WAS REPORTED DURING TREATMENT WITH A FLOW DIVERTER, UPON RESHEATHING THE DISTAL END, A COMPETITORS' MICROCATHETER KICKED BACK PROXIMALLY. THE PHYSICIAN THEN DECIDED TO RECAPTURE THE DEVICE TO REPOSITION DISTALLY AND THE STENT COULD NOT BE RECAPTURED COMPLETELY. THE STENT WAS ABLE TO BE PARTIALLY RECAPTURED WITH THE COMPETITORS MICROCATHETER AND BOTH THE STENT AND MICROCATHETER WERE COMPLETELY REMOVED WITHOUT INCIDENT. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH ANOTHER DEVICES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19316973 ↗MalfunctionJan 10, 2024Retraction Problem; Retraction Problem
IT WAS REPORTED THAT THE PATIENT WAS BEING TREATED FOR PREVIOUSLY COILED ANEURISM THAT REOCCURRED AND NEEDED MORE COILS AT UNSPECIFIED LOCATION. DURING PROCEDURE, THE COIL ASSIST LVIS EVO STENT SHOWED SOME RESISTANCE GOING THROUGH THE HEADWAY-17 MICROCATHETER. THE STENT DEPLOYED FINE BUT WAS UNABLE TO BE RE-SHEATHED DURING RE-POSITIONING ATTEMPT. THE ENTIRE SYSTEM WAS PULLED BACK IN ORDER TO MOVE THE STENT INTO PLACE FOR DEPLOYMENT. THE STENT WAS SUCCESSFULLY DETACHED AND IMPLANTED. OUTCOME WAS IDEAL AND PATIENT DID GREAT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18490104 ↗
Other Intracranial coil-assist stent devices
- Neuroform Atlas M003UZAS30240Stryker Corporation · Intracranial coil-assist stent13 reports
- Neuroform Atlas M003UZAS30210Stryker Corporation · Intracranial coil-assist stent12 reports
- Neuroform Atlas M003UZAS45210Stryker Corporation · Intracranial coil-assist stent11 reports
- Neuroform Atlas M003UZAS45300Stryker Corporation · Intracranial coil-assist stent10 reports
- Neuroform Atlas M003UZAS40210Stryker Corporation · Intracranial coil-assist stent9 reports
- Stent LEV3018-PMAMicrovention, Inc. · Intracranial coil-assist stent7 reports
- Neuroform Atlas M003UZAS40240Stryker Corporation · Intracranial coil-assist stent1 death6 reports
- Neuroform Atlas M003UZAS30150Stryker Corporation · Intracranial coil-assist stent6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.