Neuroform Atlas M003UZAS30150Recalls & reported problems
Stryker Corporation · WITHOUT TIP Stent System · Class 3 · Implant
All models of Neuroform Atlas (18)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07613327382228), received between Mar 30, 2020 and Apr 15, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Premature Activation” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Premature Activation4
- Activation Failure2
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 15, 2026Activation Failure
IT WAS REPORTED THAT PATIENT UNDERWENT STENTING PROCEDURE OF THE POSTERIOR INFERIOR CEREBELLAR ARTERY (PICA) ANEURYSM. DURING DEPLOYMENT, ONE OF STRANDS EXTENDED BEYOND THE PROXIMAL LANDING ZONE AFTER THE SUBJECT STENT WOULDN'T OPEN UP. THE PHYSICIAN TRIED TO AGITATE THE PROXIMAL END OF THE SUBJECT STENT THAT WASN'T OPENING AND THE PROCEDURE WAS COMPLETED. THE SUBJECT STENT REMAINS IMPLANTED IN THE PATIENT. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24886759 ↗MalfunctionNov 26, 2025Activation Failure; Activation Failure
IT WAS REPORTED THAT DURING PROCEDURE, THE SUBJECT STENT WAS NOT OPENING PROPERLY. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23657486 ↗MalfunctionAug 29, 2024Premature Activation; Premature Activation
I T WAS REPORTED THAT THE SUBJECT STENT DEPLOYED PREMATURELY DURING THE PROCEDURE. PROCEDURE WAS COMPLETED SUCCESSFULLY. NO FURTHER INFORMATION AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20102982 ↗MalfunctionMay 24, 2021Premature Activation; Premature Activation
IT WAS REPORTED THAT DURING THE PROCEDURE THE STENT (SUBJECT DEVICE) DEPLOYED PREMATURELY IN THE CATHETER. THE DEVICE WAS REPLACED AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THERE WERE NO CLINICAL CONSEQUENCES TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11873812 ↗MalfunctionApr 2, 2020Premature Activation; Premature Activation
IT WAS REPORTED THAT DURING THE PROCEDURE, WHILE DELIVERING THE STENT THROUGH THE GUIDE CATHETER, THE SUBJECT STENT WAS NOTED MISSING ON THE DELIVERY WIRE AND WAS NOT CONFIRMED UNDER FLUOROSCOPY. THE PROCEDURE WAS STOPPED AND THE PHYSICIAN WILL RE-ATTEMPT TO PERFORM THE PROCEDURE IN TWO WEEKS. THERE WAS NO CLINICAL CONSEQUENCES TO THE PATIENT AND THE PATIENT WAS NOT AFFECTED AS A RESULT OF THE SURGICAL DELAY OR THE DUE TO THE REPORTED EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9918848 ↗MalfunctionMar 30, 2020Premature Activation; Premature Activation
IT WAS REPORTED THAT DURING THE PROCEDURE, THE STENT (SUBJECT DEVICE) WAS MISSING, AFTER FURTHER INVESTIGATION, IT IS SUSPECTED THAT MICROCATHETER USED WAS TOO BIG AND STENT (SUBJECT DEVICE) HAD POSSIBLY DEPLOYED AT THE BASE OF THE MICROCATHETER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9900068 ↗
Other Intracranial coil-assist stent devices
- Neuroform Atlas M003UZAS30240Stryker Corporation · Intracranial coil-assist stent13 reports
- Neuroform Atlas M003UZAS30210Stryker Corporation · Intracranial coil-assist stent12 reports
- Neuroform Atlas M003UZAS45210Stryker Corporation · Intracranial coil-assist stent11 reports
- Neuroform Atlas M003UZAS45300Stryker Corporation · Intracranial coil-assist stent10 reports
- Neuroform Atlas M003UZAS40210Stryker Corporation · Intracranial coil-assist stent9 reports
- Stent LEV3018-PMAMicrovention, Inc. · Intracranial coil-assist stent7 reports
- Neuroform Atlas M003UZAS40240Stryker Corporation · Intracranial coil-assist stent1 death6 reports
- Stent LEV2517-PMAMicrovention, Inc. · Intracranial coil-assist stent5 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page