Stent LEV4027-PMARecalls & reported problems

Microvention, Inc. · LVIS EVO · Class 3 · Implant

All models of Stent (63)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842429117897), received between Dec 10, 2024 and Dec 10, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Activation Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 10, 2024Activation Failure; Activation Failure

    AS REPORTED: THE MD WAS PERFORMING A STENT/COIL OF AN ICA TERMINUS ANEURYSM USING AND LVIS 4 MM X 27 MM STENT. THE STENT WAS PREPPED ACCORDING TO IFU INSTRUCTION AND OBSERVED DISTAL OPENING. A HEADWAY 17 WAS PREPPED AND INSERTED INTO A SOFIA 6F-125CM CATHETER, ZOOM TRACKSTAR WAS USED AS A GUIDE. THE HEADWAY 17 WAS TRACKED OVER A SYNCHRO SOFT GUIDEWIRE TO THE DISTAL PORTION OF THE PCOMM VESSEL 2.54 MM IN DIAMETER, NO ACA WAS PRESENT. THE STENT WAS THEN LOADED INTO THE HEADWAY 17 AND ADVANCED WITHOUT ISSUE TO THE DISTAL PCOMM. AN SL10 WAS ALSO INSERTED INTO THE SOFIA 6F-125 CM AND ADVANCED OVER A SYNCHRO SOFT GUIDEWIRE AND INSERTED INTO THE MID REGION OF THE ANEURYSM TO BE JAILED INTO POSITION. THE MD PROCEEDED TO UNSHEATH THE STENT AND OPENING OF THE DISTAL STENT WAS OBSERVED AND CONTINUED ACROSS THE NECK OF THE ANEURYSM AND INTO THE ICA, MEASURING 3.79 MM. UNSHEATHING OF THE STENT INTO THE ICA WAS OBSERVED WITH INITIAL OPENING OF THE STENT IN STRAIGHT SEGMENT, THEN STARTING TO RIBBON AROUND THE PROXIMAL CURVE OF THE ICA. MANIPULATION OF THE STENT WAS ATTEMPTED IN AN EFFORT TO OPEN THE STENT, WHICH WAS UNSUCCESSFUL. RESHEATHING OF THE STENT WAS ADVISED AND DONE TO THE PROXIMAL NECK

    Patient problems: No Clinical Signs, Symptoms or Conditions