Dimension Vista® Flex® reagent cartridge DBIL 10445152Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · Direct Bilirubin Flex® reagent cartridge, 480 tests · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842768015649), received between Jul 31, 2019 and Jul 31, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “High Test Results” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- High Test Results1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 31, 2019High Test Results; High Test Results
DISCORDANT, FALSELY ELEVATED DIRECT BILIRUBIN (DBI) RESULTS WERE OBTAINED ON PEDIATRIC PATIENT SAMPLES ON A DIMENSION VISTA 500 SYSTEM. THE DISCORDANT RESULTS WERE REPORTED TO THE PHYSICIAN WHO QUESTIONED THE RESULTS. NEW SAMPLES WERE PROCESSED ON AN ALTERNATE DIMENSION VISTA INSTRUMENT AND LOWER RESULTS WERE OBTAINED. CORRECTED REPORTS WERE ISSUED. ONE PATIENT (SAMPLE ID (B)(6)) WAS TREATED FOR THE ELEVATED DBI RESULT BY HAVING ADDITIONAL BLOOD DRAWS, BEING FED A SPECIAL FORMULA INSTEAD OF BREASTMILK AND HAVING A LIVER ULTRASOUND WHICH GAVE A NORMAL RESULT. THERE WERE NO ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT FALSELY ELEVATED DBI RESULTS OR DUE TO THE TREATMENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8845546 ↗
Other DIAZO COLORIMETRY, BILIRUBIN devices
- Dimension® Flex® reagent cartridge TBI 10444957Siemens Healthcare Diagnostics Inc. · DIAZO COLORIMETRY, BILIRUBIN2 recalls4 reports
- Dimension Vista® Flex® reagent cartridge TBIL 10445146Siemens Healthcare Diagnostics Inc. · DIAZO COLORIMETRY, BILIRUBIN1 recall7 reports
- VITROS 8383051Ortho-Clinical Diagnostics, Inc. · DIAZO COLORIMETRY, BILIRUBIN1 recall5 reports
- VITROS 1612365Ortho-Clinical Diagnostics, Inc. · DIAZO COLORIMETRY, BILIRUBIN1 recall1 report
- ARCHITECT 6L45-21Abbott Laboratories · DIAZO COLORIMETRY, BILIRUBIN46 reports
- ARCHITECT 6L45-22Abbott GmbH · DIAZO COLORIMETRY, BILIRUBIN30 reports
- ARCHITECT 6L45-41Abbott Laboratories · DIAZO COLORIMETRY, BILIRUBIN18 reports
- Bilirubin Direct Gen.2 08056951190Roche Diagnostics GmbH · DIAZO COLORIMETRY, BILIRUBIN17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page