Tornier HRS ARS741801Recalls & reported problems

Tornier, Inc. · PTC Distal Stem · Class 2 · Implant

All models of Tornier HRS (40)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
14
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 00846832093014), received between Aug 23, 2023 and Sep 17, 2026 — classified as 14 injuries.

The most frequently reported specific device problem is “Osseointegration Problem” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 2 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem4
  • Osseointegration Problem4
  • Unstable3
  • Detachment of Device or Device Component1
  • Device Dislodged or Dislocated1
  • Fracture1
  • Loss of Osseointegration1

Patient problems

  • Inadequate Osseointegration4
  • Joint Laxity3
  • Osteolysis3
  • Unspecified Infection3
  • Bone Fracture(s)2
  • Limb Fracture1
  • Rheumatoid Arthritis1
  • Subluxation1

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • InjurySep 17, 2026Unstable

    The manufacturer received a report from the National Joint Registry that contains unpublished collected data on the usage and the outcomes of the shoulder joint replacement. The report details analysis provided for revision procedures performed until Aug 2026.During the review of the report, it was identified that on (b)(6)2026 a patient required revision surgery due to instability, which was not previously reported to the manufacturer.

    Patient problems: Joint Laxity

    MAUDE report 50803916 ↗
  • InjuryMay 15, 2026Unstable

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED BETWEEN MARCH 2025-MARCH 2026. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025, A PATIENT REQUIRED REVISION SURGERY DUE TO INSTABILITY, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Joint Laxity

    MAUDE report 25180909 ↗
  • InjuryApr 29, 2026Unstable

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2026. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT A PATIENT REQUIRED REVISION SURGERY DUE TO INSTABILITY, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Joint Laxity

    MAUDE report 25024742 ↗
  • InjuryFeb 23, 2026Fracture; Loss of Osseointegration

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED IN 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO PERIPROSTHETIC FRACTUR AND ASEPTIC LOOSENING HUMERUS AND IMPLANT FRACTURE, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Bone Fracture(s); Osteolysis

    MAUDE report 24414123 ↗
  • InjuryDec 1, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED IN 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Unspecified Infection

    MAUDE report 23687209 ↗
  • InjuryNov 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED BETWEEN (B)(6) 2023 - (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Unspecified Infection

    MAUDE report 23550300 ↗
  • InjurySep 22, 2025Osseointegration Problem; Osseointegration Problem

    THE DISENGAGEMENT OF ASSEMBLY SCREW WITHIN PROXIMAL AND DISTAL BODY CAUSING THE PROXIMAL PART OF REVIVE STEM TO BECOME UNSTABLE RESULTING IN REVISION SURGERY WAS REPORTED. ALSO, POROUS COATING OF PROXIMAL PART OF STEM HAS ERODED/COME OFF THE STEMS SURFACE. PATIENT HAD SYMPTOMS AND HEARD AN AUDIBLE CLUNK, X RAY OF STEM CONFIRMED ISSUE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 23111639 ↗
  • InjurySep 8, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO PERIPROSTHETIC FRACTURE AND COMPONENT DISSOCIATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Bone Fracture(s)

    MAUDE report 22993006 ↗
  • InjuryMay 26, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO LYSIS OF HUMERUS, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Osteolysis

    MAUDE report 22084117 ↗
  • InjuryMar 19, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024, A PATIENT REQUIRED REVISION SURGERY DUE TO DISLOCATION/SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Subluxation

    MAUDE report 21644289 ↗
  • InjuryJun 4, 2024Osseointegration Problem; Osseointegration Problem

    AS REPORTED: "OPERATION DATE (B)(6) 2023. PATIENT USED REVIVE STEM WITH PERFORM REVERSE. REP OF THE CASE AS DEFINITELY SAID THERE WAS A LOCKING CAP USED. THE NURSE STRUGGLING INITIALLY WITH THE CAP AND SURGEON THEMSELVES TIGHTENING THE CAP. THE INITIAL XR THE STEM WAS STANDARD. 3 MONTH POST OP THE WAS A GAP BETWEEN PROXIMAL BODY AND DISTAL STEM (ON X-RAY). FINAL XR 7 MONTHS PO THE STEM IS NOW JOINED AGAIN. WE HAVE INQUIRED WHETHER THE PATIENT IS FEELING THESE SHIFTS AND WHETHER THE SURGEON WOULD LIKE TO GO AHEAD WITH THE REVISION AND ASKED IF THEY WILL CONDUCT MORE XRS UNDER COMPRESSION AND NOT TO SEE IF THE IMPLANT IS SHIFTING. LOCKING CAP WAS ON USAGE.".

    Patient problems: Inadequate Osseointegration

    MAUDE report 19464077 ↗
  • InjuryApr 22, 2024Osseointegration Problem; Osseointegration Problem

    REMOVAL OF FLEX REVIVE STEM AND WIRES AND REPLACEMENT WITH CEMENT SPACER DUE TO DISTAL HUMERAL (LIKELY) INFECTION AND PROSTHETIC LOOSENING. THE PATIENT HAS RA AND A BONE DENSITY DEFICIENCY. THE REVIVE STEM WAS USED TO STABILIZE THE DISPLACED DISTAL HUMERUS AND CABLES USED TO SECURE THE BONE. THERE WAS EVIDENCE OF LOOSENING OF THE THE DISTAL HUMERUS ONLY AND NO EVIDENCE ON XR OF ANY SHOULDER JOINT ISSUE.

    Patient problems: Inadequate Osseointegration; Rheumatoid Arthritis; Unspecified Infection

    MAUDE report 19159669 ↗
  • InjuryDec 22, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT SUFFERED A INTRAOPERATIVE GT FRACTURE WHICH WAS TREATED WITH SUTURE CERCLAGE.

    Patient problems: Limb Fracture

    MAUDE report 18388951 ↗
  • InjuryAug 23, 2023Osseointegration Problem; Osseointegration Problem

    THE TORNIER SHOULDER OUTCOMES STUDY'S PATIENT EXPERIENCED A REVISION SURGERY DUE TO ISSUES WITH LOOSENING/LYSIS. DURING THE PROCEDURE, A GLENOID SPHERE WAS REMOVED AND REPLACED WITH A REVERSED-LATERALIZED GLENOSPHERE THAT WAS 3MM LARGER (39MM). AN ADDITIONAL UPDATE REVEALED THAT THE TORNIER HRS ARS741701 WAS ALSO REMOVED DURING THE SURGERY.

    Patient problems: Inadequate Osseointegration; Osteolysis

    MAUDE report 17606936 ↗

Other PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices

All PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page