Tornier HRS ARS655102Recalls & reported problems
Tornier, Inc. · Assembly Screw · Class 2 · Implant
All models of Tornier HRS (40)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00846832093267), received between Jun 26, 2023 and Apr 15, 2026 — classified as 8 injuries.
The most frequently reported specific device problem is “Osseointegration Problem” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Osseointegration Problem4
- Device Dislodged or Dislocated3
- Migration2
- Adverse Event Without Identified Device or Use Problem1
- Biocompatibility1
- Fracture1
- Loosening of Implant Not Related to Bone-Ingrowth1
- Loss of Osseointegration1
Patient problems
- Inadequate Osseointegration4
- Discomfort2
- Fall2
- Joint Dislocation2
- Osteolysis2
- Metal Related Pathology1
- No Clinical Signs, Symptoms or Conditions1
- Pain1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjuryApr 15, 2026Fracture
A REVISION SURGERY HAS BEEN PERFORMED DUE TO A BROKEN SCREW ON THE REVIVE STEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24888393 ↗InjuryApr 21, 2025Biocompatibility; Device Dislodged or Dislocated; Loosening of Implant Not Related to Bone-Ingrowth; Biocompatibility; Device Dislodged or Dislocated; Loosening of Implant Not Related to Bone-Ingrowth
ORIGINAL PROCEDURE TOOK PLACE IN 2024. PROCEDURE WAS A REVISION OF ANOTHER COMPANIES ANATOMIC SHOULDER REPLACEMENT. REVISION ON A POLY SWAP AND GLENOSPHERE EXCHANGE. X-RAYS IN THEATRE SHOW FLEX REVIVE SCREW AND CAP HAVE BACKED OUT OF PROSTHESIS MAKING THE CONSTRUCT LOOSE. PATIENT SHOWED CLEAR SIGNS OF METALOSIS AND QUERY INFECTION. ALL IMPLANTS EXTRACTED AND CEMENT SPACER IMPLANTED.
Patient problems: Joint Dislocation; Metal Related Pathology
MAUDE report 21878040 ↗InjuryMar 10, 2025Device Dislodged or Dislocated; Osseointegration Problem; Migration; Device Dislodged or Dislocated; Osseointegration Problem; Migration
IT WAS REPORTED BY COUNSEL THAT CLAIMANT UNDERWENT REVISION OF HIS RIGHT SHOULDER ON (B)(6) 2024, WITH TORNIER AEQUALIS IMPLANTS AND WAS REVISED ON (B)(6) 2024, DUE TO ALLEGED CONTINUED PAIN, SENSE OF CATCHING AND SLIGHT EVIDENCE OF MOTION OF THE TUBEROSITY FRACTURES. PATIENT WAS 3 WEEKS POST OP FROM A REVERSE SHOULDER ARTHROPLASTY. PATIENT HAD 2 FALLS POST-OP, ONE IN THE HOSPITAL AND WHEN AT HOME. PATIENT COMPLAINED OF CONTINUED PAIN AND A SENSE OF CATCHING IN THE SHOULDER AND THERE WAS SLIGHT EVIDENCE OF MOTION OF THE TUBEROSITY FRACTURE. ADDITIONALLY WITH ONE OF THE FALLS THE PATIENTS WOUND RE-OPENED AND HE WAS HAVING SOME DRAINAGE. DURING THE REVISION IT WAS NOTED THAT THE LOCKING SCREW FROM THE BODY TO THE DISTAL PORTION OF THE STEM HAD LOOSENED AND THE DISTAL PART OF THE STEM WAS WELL FIXED, THE BODY WAS FREELY MOVING. THE LOCKING CAP OVER THE SCREW WAS COMPLETELY INTACT BUT THE SCREW DEEP TO IT HAD LOOSENED. ALL OF THE IMPLANTS WERE REMOVED AND REPLACED.
Patient problems: Discomfort; Fall; Inadequate Osseointegration; Pain; Wound Dehiscence
MAUDE report 21561455 ↗InjuryFeb 4, 2025Osseointegration Problem; Osseointegration Problem
AS REPORTED: "REVIVE HUMERAL STEM APPEARS TO BE SEPARATING. THE LOCKING CAP AND THE ASSEMBLY SCREWS SEEM TO BE BACKING OUT CAUSING THE PROXIMAL BODY, THE SPACER AND THE DISTAL STEM TO BE MIGRATING AWAY FROM EACH OTHER."
Patient problems: Inadequate Osseointegration
MAUDE report 21307314 ↗InjuryOct 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY DUE TO DISCOMFORT.
Patient problems: Discomfort
MAUDE report 20508303 ↗InjuryOct 8, 2024Loss of Osseointegration; Loss of Osseointegration
IT WAS REPORTED THAT THE PATIENT COMPLAINED OF "GRINDING" WITH MOVEMENT DURING POST-OPERATIVE VISITS. A FALL RESULTED IN A FRACTURE OF THE GREATER TUBEROSITY, REQUIRING SURGICAL INTERVENTION. DURING FRACTURE FIXATION, IT WAS OBSERVED THAT THE PROXIMAL BODY HAD LOOSENED FROM THE STEM. FURTHER INSPECTION REVEALED THAT WHILE THE LOCKING CAP WAS FULLY SEATED, THE SCREW HAD LOOSENED FROM THE DISTAL STEM.
Patient problems: Fall; Inadequate Osseointegration; Osteolysis
MAUDE report 20400004 ↗InjuryApr 22, 2024Osseointegration Problem; Osseointegration Problem
REMOVAL OF FLEX REVIVE STEM AND WIRES AND REPLACEMENT WITH CEMENT SPACER DUE TO DISTAL HUMERAL (LIKELY) INFECTION AND PROSTHETIC LOOSENING. THE PATIENT HAS RA AND A BONE DENSITY DEFICIENCY. THE REVIVE STEM WAS USED TO STABILIZE THE DISPLACED DISTAL HUMERUS AND CABLES USED TO SECURE THE BONE. THERE WAS EVIDENCE OF LOOSENING OF THE DISTAL HUMERUS ONLY AND NO EVIDENCE ON XR OF ANY SHOULDER JOINT ISSUE.
Patient problems: Inadequate Osseointegration; Rheumatoid Arthritis; Unspecified Infection
MAUDE report 19160110 ↗InjuryJun 26, 2023Device Dislodged or Dislocated; Osseointegration Problem; Migration; Device Dislodged or Dislocated; Osseointegration Problem; Migration
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION PROCEDURE OF STEM, METAPHYSIS AND INSERT DUE TO HUMERAL REVIVE PROSTHESIS DISSOCIATION AND POSSIBLE SCREW LOOSENING. GLENOID BASEPLATE AND GLENOSPHERE WERE RETAINED FROM PRIOR PROCEDURE. ASSESSED AS DEFINITELY RELATED TO THE STUDY DEVICE, AND POSSIBLY RELATED TO THE SURGICAL PROCEDURE BY THE INVESTIGATOR.
Patient problems: Joint Dislocation; Osteolysis
MAUDE report 17200179 ↗
Other PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices
- DJO SURGICAL 509-02-032Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED364 reports
- DELTA XTEND 130790036Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED171 reports
- DELTA XTEND 130770018Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED159 reports
- TRIGEN 71118200Smith & Nephew, Inc. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED123 reports
- DJO SURGICAL 509-02-432Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED119 reports
- DELTA XTEND 130738206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED116 reports
- COMPREHENSIVE SHOULDER SYSTEM 113633Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED2 recalls4 reports
- DELTA XTEND 130742206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED99 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page