ONESTEP 8900-0224-01Recalls & reported problems
Zoll Medical Corporation · ELECTRODES, ONESTEP COMPLETE, SINGLE, R SERIES · Class 3
All models of ONESTEP (8)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Zoll OneStep electrode pad set is a disposable pad that connects a patient to a defibrillator. Its 489 reports most often describe the device being unable to obtain readings and failing self-tests. Recent reports describe pads that would not separate from their backing, and one describes chest burns. The reports include 36 injuries and 15 deaths. Reports fell from 47 the year before to 32 in the latest year.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 487
- Deaths reported
- 15
- Injuries reported
- 35
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 487 adverse event reports that list this exact device (DI 00847946016272), received between Aug 4, 2015 and Sep 30, 2026 — classified as 15 deaths, 35 injuries, 437 malfunctions.
The most frequently reported specific device problem is “Unable to Obtain Readings” (172 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Unable to Obtain Readings172
- Failure of Device to Self-Test88
- Patient Device Interaction Problem55
- Device Operational Issue35
- Device Displays Incorrect Message19
- Failure to Deliver Shock/Stimulation16
- Pacing Problem12
- Sparking9
Patient problems
- No Clinical Signs, Symptoms or Conditions194
- No Patient Involvement134
- Insufficient Information52
- No Information44
- Burn(s)23
- No Consequences Or Impact To Patient12
- Death8
- Partial thickness (Second Degree) Burn8
Recent adverse event reports
The 25 most recent of 487 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 30, 2026Unable to Obtain Readings
COMPLAINANT ALLEGED WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE DEVICE WAS UNABLE TO OBTAIN AN ECG SIGNAL VIA ELECTRODE PADS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: Insufficient Information
MAUDE report 50947537 ↗MalfunctionSep 17, 2026Failure of Device to Self-Test
COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEVICE FAILED SELF TEST USING THESE ELECTRODE PADS.COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50804517 ↗MalfunctionSep 4, 2026Gel Leak; Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO DEFIBRILLATE AN 64-YEAR-OLD MALE PATIENT, THE ELECTRODES WOULD NOT ADHERE TO THE PATIENT'S SKIN AND GEL MIGRATION.COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50612976 ↗MalfunctionSep 4, 2026Failure of Device to Self-Test
COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEFIBRILLATOR FAILED SELF TEST.\\COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50612234 ↗InjuryAug 28, 2026Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE DEFIBRILLATING AN 85-YEAR-OLD FEMALE PATIENT, AFTER REMOVING THE ELECTRODE PADS, BURNS WERE FOUND ON THE PATIENT. COMPLAINANT INDICATED THAT THE PATIENT SUSTAINED STERNAL BURNS. NO FURTHER INFORMATION WAS AVAILABLE.
Patient problems: Burn(s)
MAUDE report 50497987 ↗MalfunctionAug 17, 2026Failure of Device to Self-Test
COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEVICE FAILED SELF TEST USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50275253 ↗MalfunctionAug 14, 2026Sparking
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50253535 ↗MalfunctionMay 1, 2026Unable to Obtain Readings
COMPLAINANT ALLEGED WHILE ATTEMPTING TO MONITOR A PATIENT (AGE & GENDER UNKNOWN), THE ASSOCIATED DEVICE DISPLAYED A "GENERAL ELECTRODE FAULT" MESSAGE. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER SET OF ONESTEP PADS TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25056056 ↗InjuryApr 8, 2026Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE DEFIBRILLATING A PATIENT (AGE & GENDER UNKNOWN), AFTER REMOVING THE ELECTRODE PADS, BURNS WERE FOUND ON THE PATIENT. COMPLAINANT INDICATED THAT THE PATIENT SUFFERED BURNS. NO INFORMATION WAS AVAILABLE ON THE DEGREE OF BURNS.
Patient problems: Burn(s)
MAUDE report 24815567 ↗MalfunctionMar 30, 2026Failure of Device to Self-Test
COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEVICE FAILED SELF TEST USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24728228 ↗MalfunctionMar 19, 2026Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ELECTRODE PADS EXPERIENCED ADHESIVE PROBLEMS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: Insufficient Information
MAUDE report 24643489 ↗MalfunctionMar 3, 2026Electrical Shorting
COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEVICE DISPLAYED A "POOR PAD CONTACT" MESSAGE. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24498395 ↗MalfunctionMar 3, 2026Material Separation; Sparking
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A 66-YEAR-OLD MALE PATIENT, AFTER MULTIPLE DISCHARGES THE PADS WERE REPLACED, THE PATIENT'S CHEST WAS WIPED, AND UPON SHOCK DELIVERY A SPARK WAS OBSERVED FROM THE DEFIBRILLATION PADS. IT WAS ALSO REPORTED THAT THE WIRE SEPARATED FROM THE ELECTRODE. NO BURNS WERE OBSERVED ON THE PATIENT'S SKIN. COMPLAINANT INDICATED THE PATIENT SUBSEQUENTLY EXPIRED BUT WAS NOT A RESULT OF THE MALFUNTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24496135 ↗MalfunctionMar 2, 2026Failure to Deliver Shock/Stimulation
COMPLAINANT ALLEGED WHILE ATTEMPTING TO TREAT A 63-YEAR-OLD MALE PATIENT, THE ASSOCIATED DEVICE FAILED TO DISCHARGE USING THESE ONE-STEP PADS. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER DEVICE TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24483492 ↗MalfunctionFeb 27, 2026Unable to Obtain Readings
COMPLAINANT ALLEGED THAT DURING BIOMED TESTING, THE ASSOCIATED DEFIBRILLATOR WAS UNABLE TO DETECT THE ATTACHED ELECTRODES. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24470239 ↗MalfunctionFeb 20, 2026Unable to Obtain Readings
COMPLAINANT ALLEGED WHILE ATTEMPTING TO TREAT AN 81-YEAR-OLD PATIENT (GENDER UNKNOWN), A GROUND WIRE APPEARED TO REMAIN ATTACHED TO THE DEFIBRILLATION PADS WHILE ON THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION. MEDWATCH NUMBER:(B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24405418 ↗MalfunctionFeb 20, 2026Unable to Obtain Readings
THE ASSOCIATED DEVICE FAILED THE SELF-TEST USING THESE ONESTEP PADS, THE DEVICE DISPLAYED A "PADDLE FAULT" MESSAGE. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24402201 ↗MalfunctionFeb 16, 2026Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A 72-YEAR-OLD MALE PATIENT, THE ELECTRODES WOULD NOT ADHERE TO THE PATIENT'S SKIN. THREE SETS OF ELECTRODES WERE USED DURING THE PATIENT EVENT. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: Insufficient Information
MAUDE report 24344242 ↗MalfunctionFeb 13, 2026Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A 72-YEAR-OLD MALE PATIENT, THE ELECTRODES WOULD NOT ADHERE TO THE PATIENT'S SKIN. THREE SETS OF ELECTRODES WERE USED DURING THE PATIENT EVENT. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: Insufficient Information
MAUDE report 24338085 ↗MalfunctionFeb 13, 2026Patient Device Interaction Problem
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A 72-YEAR-OLD MALE PATIENT, THE ELECTRODES WOULD NOT ADHERE TO THE PATIENT'S SKIN. THREE SETS OF ELECTRODES WERE USED DURING THE PATIENT EVENT. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: Insufficient Information
MAUDE report 24338074 ↗MalfunctionFeb 12, 2026Unable to Obtain Readings
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE DEVICE WAS UNABLE TO OBTAIN AN ECG SIGNAL VIA ELECTRODE PADS. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER DEVICE TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: Ventricular Fibrillation
MAUDE report 24324763 ↗MalfunctionFeb 6, 2026Failure of Device to Self-Test
COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEVICE FAILED SELF TEST USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24279636 ↗MalfunctionJan 30, 2026
ZOLL ONESTEP CPR COMPLETE PADS PACKAGE WAS OPENED IN ORDER TO PLACE PADS ON PATIENT. UPON PULLING THE PADS APART, THE WIRES BROKE APART, EXPOSING THE WIRES OPN THE PADS. THE PADS WERE REMOVED FROM SERVICE AND A NEW PACKAGE OF PADS WAS OBTAINED FOR USE. THE PADS WERE NOT USED ON THE PATIENT, THEREFORE NO PATIENT HARM FROM THESE PADS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24220633 ↗MalfunctionJan 28, 2026Accessory Incompatible; Sparking
COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO CARDIOVERT A PATIENT (AGE & GENDER UNKNOWN), A SPARK WAS SEEN AND POPPING WAS HEARD FROM ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24198875 ↗MalfunctionDec 19, 2025Failure of Device to Self-Test; Failure of Device to Self-Test
COMPLAINANT ALLEGED THAT DURING FUNCTIONAL TESTING, THE ASSOCIATED DEVICE FAILED SELF TEST USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23853625 ↗
FDA clearance and classification
The FDA regulates product code MKJ (automated external defibrillators (non-wearable)) under 21 CFR 870.5310 as a Class III device. 21 CFR 870.5310 ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
FDA definition of this device type: This device is a non-wearable prescription use only aed. These are devices that include automated external defibrillation. Automated external defibrillators use external pad-type electrodes to sense, detect, classify and treat (with an electrical shock) ventricular fibrillation. These devices are intended to be used on suspected victims of sudden cardiac arrest. A person in cardiac arrest is unresponsive and is not breathing normally. The device can be sold with prescription only.
Common questions about the ONESTEP 8900-0224-01
Has the ONESTEP 8900-0224-01 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00847946016272), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the ONESTEP 8900-0224-01?
The FDA's MAUDE database lists 487 adverse event reports for this device, received between Aug 4, 2015 and Sep 30, 2026. In those reports, the most common specific device problems are “Unable to Obtain Readings” (172), “Failure of Device to Self-Test” (88) and “Patient Device Interaction Problem” (55); the most common patient problems are “Burn(s)” (23), “Death” (8) and “Partial thickness (Second Degree) Burn” (8). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ONESTEP 8900-0224-01?
15 reports are classified as deaths, 35 as injuries and 437 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the ONESTEP 8900-0224-01 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.
Who makes the ONESTEP 8900-0224-01, and is it still sold?
The FDA's device database lists Zoll Medical Corporation as the company responsible for it (brand ONESTEP, model 8900-0224-01). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Automated external defibrillators (non-wearable) devices
- NA 861290Philips Medical Systems Hsg · Automated External Defibrillators (Non-Wearable)12 deaths5,163 reports
- NA 861288Philips Medical Systems Hsg · Automated External Defibrillators (Non-Wearable)21 deaths5,012 reports
- NA 861289Philips Medical Systems Hsg · Automated External Defibrillators (Non-Wearable)7 deaths3,384 reports
- R SERIES 30001005201310012Zoll Medical Corporation · Automated external defibrillators (non-wearable)10 deaths1,719 reports
- PHILIPS HeartStart FRxPhilips Electronics North America Corporation · Automated external defibrillators (non-wearable)26 deaths1,582 reports
- LIFEPAK CR2 99512Physio-Control, Inc. · Automated external defibrillators (non-wearable)8 deaths1,502 reports
- Lifeline Configuration DDU-100ADefibtech, L.L.C. · Automated External Defibrillators (Non-Wearable)1 death1,285 reports
- PHILIPS HeartStart FR3Philips Electronics North America Corporation · Automated External Defibrillators (Non-Wearable)10 deaths1,188 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page