PRO PADZ 8900-2302-01Recalls & reported problems

Zoll Medical Corporation · PRO*PADZ BIPHASIC MULTI-FUNCTION ELECTRODES - 1 PAIR · Class 3

All models of PRO PADZ (6)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00847946016418), received between Jun 6, 2018 and Sep 22, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Arcing of Electrodes” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Arcing of Electrodes1
  • Device Displays Incorrect Message1
  • Failure to Capture1
  • Noise, Audible1
  • Patient Device Interaction Problem1
  • Sparking1
  • Use of Device Problem1

Patient problems

  • Insufficient Information2
  • No Clinical Signs, Symptoms or Conditions2
  • No Information2

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 22, 2025Failure to Capture; Failure to Capture

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO PACE A MALE PATIENT (AGE UNKNOWN), THE DEVICE FAILED TO CAPTURE THE PATIENT'S HEART RHYTHM. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER SET OF PADS TO CONTINUE TREATING THE PATIENT. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: Insufficient Information

    MAUDE report 23112104 ↗
  • MalfunctionApr 1, 2022Arcing of Electrodes; Noise, Audible; Arcing of Electrodes; Noise, Audible

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO CARDIOVERT A PATIENT (AGE & GENDER UNKNOWN), AN ARC WAS SEEN FROM THE ELECTRODE PADS AND A LOUD POP NOISE WAS HEARD. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13979372 ↗
  • MalfunctionFeb 14, 2022Use of Device Problem; Use of Device Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), TWO SETS OF ELECTRODE PADS NEEDED TO BE REPLACED DURING CHEST COMPRESSIONS, CAUSING UNNECESSARY DELAYS IN DELIVERING THERAPY. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED A SET OF PADDLES TO CONTINUE TREATING THE PATIENT. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: Insufficient Information

    MAUDE report 13525218 ↗
  • MalfunctionAug 23, 2021Sparking; Sparking

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO CARDIOVERT A MID-70'S-YEAR-OLD MALE PATIENT, A RED GLOW (SPARK) WAS SEEN COMING FROM THE ATTACHED ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12355903 ↗
  • MalfunctionAug 14, 2019Patient Device Interaction Problem; Patient Device Interaction Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO DEFIBRILLATE A PATIENT (AGE & GENDER UNKNOWN), THE ELECTRODES WOULD NOT ADHERE TO THE PATIENT'S SKIN. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Information

    MAUDE report 8895028 ↗
  • MalfunctionJun 6, 2018Device Displays Incorrect Message; Device Displays Incorrect Message

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ASSOCIATED DEVICE DISPLAYED A "CHECK PADS" MESSAGE USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED SEVERAL SETS OF ELECTRODE PADS (ONE SAME LOT 1518 AND ONE DIFFERENT LOT 1218 - MANUFACTURE DATE OF 3/19/2018 EXPIRATION DATE OF 12/19/2019) TO CONTINUE TREATING THE PATIENT AND THE "CHECK PADS" MESSAGE APPEARED. THE COMPLAINANT INDICATED THAT THIS CAUSED A DELAY IN THE TREATMENT OF THE PATIENT. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Information

    MAUDE report 7574034 ↗

Other Automated External Defibrillators (Non-Wearable) devices

All Automated External Defibrillators (Non-Wearable) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page