Skip to content

ONESTEP 8900-000219-01Recalls & reported problems

Zoll Medical Corporation · ONESTEP PEDIATRIC CPR ELECTRODE, SINGLE · Class 3

All models of ONESTEP (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Zoll OneStep pediatric CPR electrode pad is a single-use adhesive pad used with automated external defibrillators on children. Reports mostly describe pads that will not stick to the skin, layers separating or tearing when pulled from the packaging, and the defibrillator failing to pick up a heart rhythm reading or deliver a shock. There are 28 reports, including 4 deaths and no injuries, with 24 malfunctions. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
28
Deaths reported
4
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 28 adverse event reports that list this exact device (DI 00847946023348), received between Mar 13, 2017 and Feb 11, 2025 — classified as 4 deaths, 24 malfunctions.

The most frequently reported specific device problem is “Unable to Obtain Readings” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 2 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unable to Obtain Readings8
  • Patient Device Interaction Problem4
  • Device Displays Incorrect Message3
  • Failure to Deliver Shock/Stimulation3
  • Packaging Problem3
  • Device Operational Issue1
  • Device Packaging Compromised1
  • Failure of Device to Self-Test1

Patient problems

  • No Clinical Signs, Symptoms or Conditions13
  • No Patient Involvement7
  • Death2
  • Insufficient Information2
  • Necrosis2
  • No Consequences Or Impact To Patient1
  • No Information1

Recent adverse event reports

The 25 most recent of 28 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 11, 2025Failure of Device to Self-Test; Failure of Device to Self-Test

    COMPLAINANT ALLEGED THAT DURING FUNCTIONAL TESTING, THE ASSOCIATED DEVICE FAILED THE SELF-TEST USING THESE ONESTEP PEDIATRIC PADS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21357478 ↗
  • MalfunctionSep 9, 2024Patient Device Interaction Problem; Patient Device Interaction Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ELECTRODES WOULD NOT ADHERE TO THE PATIENT'S SKIN. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20171290 ↗
  • MalfunctionAug 28, 2024Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A 2-MONTH-OLD MALE PATIENT, THE ELECTRODE PADS WERE DAMAGED DURING THE REMOVAL OF PACKAGING. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20085821 ↗
  • MalfunctionAug 6, 2024

    INFANT PATIENT CAME INTO THE EMERGENCY DEPARTMENT BEING GIVEN CPR BY EMS CREW. PATIENT MOVED TO RESUSCITATION ROOM. STAFF OPENED PACKAGE OF ONESTEP CPR ZOLL MONITOR PADS, AND WHEN POSTERIOR PAD WAS PULLED FROM SHEET, THE PAD SEPARATED. IT SEPARATED BETWEEN THE BOTTOM WHITE FOAM PAD AND THE BLUE FOAM LAYER. THEY COMPLETELY SEPARATED. STAFF PLACED THE LAYERS BACK TOGETHER AND PLACED ON PATIENT BUT COULD NOT GET READING/RHYTHM. THEY OPENED ANOTHER ONESTEP MONITOR PADS PACKAGE, AND THE SAME THING HAPPENED, AGAIN ONLY TO THE POSTERIOR PAD. BY THIS TIME, THEY HAD PUT OTHER MONITOR ELECTRODES ON PATIENT, AND COULD SEE THAT HE WAS NOT IN A SHOCKABLE RHYTHM. THE FAILURE OF THE ZOLL ONESTEP PADS COULD HAVE BEEN DETRIMENTAL TO THE PATIENT BECAUSE IF HE WAS IN A SHOCKABLE RHYTHM, THEY WOULD HAVE WANTED TO USE THAT MONITOR TO SHOCK HIM, WHICH THOSE PADS HAVE THE ABILITY TO DO WHEN WORKING CORRECTLY. IN THIS CASE THOUGH, HE WAS NOT IN A SHOCKABLE RHYTHM; SO THE FAILURE OF THE ZOLL MONITOR PADS DID NOT CAUSE ANY HARM/INJURY. STAFF HAD THE ACTUAL ZOLL MONITOR CHECKED THREE DIFFERENT TIMES THAT DAY, AND ALL THREE TECHS SAID THE MONITOR WAS WORKING CORRECTLY, SO OUR CONCLUSION IS THE PADS WERE WHAT

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19917101 ↗
  • MalfunctionOct 4, 2023Failure to Deliver Shock/Stimulation; Failure to Deliver Shock/Stimulation

    COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEFIBRILLATOR FAILED TO DISCHARGE USING THESE ATTACHED ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17868336 ↗
  • MalfunctionJan 9, 2023Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ASSOCIATED DEVICE WAS UNABLE TO OBTAIN AN ECG SIGNAL VIA THESE ATTACHED ELECTRODE PADS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: Insufficient Information

    MAUDE report 16125807 ↗
  • DeathNov 18, 2022Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO DEFIBRILLATE A 4-MONTH-OLD MALE PATIENT, THE ASSOCIATED DEVICE WAS UNABLE TO OBTAIN AND ECG SIGNAL USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THE PATIENT SUBSEQUENTLY EXPIRED.

    Patient problems: Necrosis

    MAUDE report 15828771 ↗
  • MalfunctionSep 28, 2022Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEFIBRILLATOR WAS UNABLE TO DETECT THE ATTACHED ELECTRODES. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15496775 ↗
  • MalfunctionJul 8, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ELECTRODE PADS WOULD NOT ADHERE TO THE PATIENT'S SKIN. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION. PLEASE REFERENCE MEDWATCH REPORT NUMBERS 1218058-2022-00065, 1218058-2022-00067, 1218058-2022-00059 FOR SIMILAR REPORTS FROM THE SAME CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14959390 ↗
  • MalfunctionJul 8, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ELECTRODE PADS WOULD NOT ADHERE TO THE PATIENT'S SKIN. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION. PLEASE REFERENCE MEDWATCH REPORT NUMBERS 1218058-2022-00066, 1218058-2022-00067, 1218058-2022-00059 FOR SIMILAR REPORTS FROM THE SAME CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14957346 ↗
  • MalfunctionJul 8, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE & GENDER UNKNOWN), THE ELECTRODE PADS WOULD NOT ADHERE TO THE PATIENT'S SKIN. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION. PLEASE REFERENCE MEDWATCH REPORT NUMBERS 1218058-2022-00066, 1218058-2022-00065, 1218058-2022-00059 FOR SIMILAR REPORTS FROM THE SAME CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14957318 ↗
  • MalfunctionMar 15, 2022Packaging Problem; Packaging Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A (B)(6) MALE PATIENT, THE PADS WERE DAMAGED DURING OPENING/REMOVAL OF PACKAGING AND THEY WERE UNABLE TO ATTACH THEM TO THE PATIENT CAUSING A DELAY IN THERAPY. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13771893 ↗
  • DeathJan 6, 2022Packaging Problem; Packaging Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A (B)(6) YEAR OLD PATIENT (GENDER UNKNOWN), THE PADS WERE DAMAGED DURING OPENING/REMOVAL OF PACKAGING AND THEY WERE UNABLE TO ATTACH THEM TO THE PATIENT CAUSING A DELAY IN THERAPY. COMPLAINANT INDICATED THAT THE PATIENT SUBSEQUENTLY EXPIRED.

    Patient problems: Necrosis

    MAUDE report 13181579 ↗
  • MalfunctionDec 2, 2021Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO MONITOR A PATIENT (AGE & GENDER UNKNOWN), THE ATTACHED DEFIBRILLATOR WAS UNABLE TO OBTAIN AN ECG SIGNAL USING THESE ELECTRODE PADS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: Insufficient Information

    MAUDE report 12919201 ↗
  • MalfunctionSep 7, 2021Mechanical Problem; Mechanical Problem

    COMPLAINANT INDICATED THAT WHILE ANTICIPATING THE TREATMENT OF AN ALREADY DECEASED (B)(6) OLD FEMALE PATIENT, THAT A WIRE HAD BECOME DISLODGED FROM THE ELECTRODE PAD. COMPLAINANT INDICATED THAT UPON ASSESSMENT OF THE PATIENT, MOTTLING AND RIGOR MORTIS WERE APPARENT PRIOR TO USE OF THE DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12436237 ↗
  • MalfunctionApr 16, 2021Failure to Deliver Shock/Stimulation; Failure to Deliver Shock/Stimulation

    COMPLAINANT ALLEGED THAT DURING FUNCTIONAL TESTING, THE ASSOCIATED DEFIBRILLATOR FAILED TO DISCHARGE USING THESE ATTACHED ELECTRODE PADS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11679554 ↗
  • MalfunctionApr 14, 2021Failure to Deliver Shock/Stimulation; Failure to Deliver Shock/Stimulation

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO DEFIBRILLATE A PATIENT (AGE & GENDER UNKNOWN), THE ASSOCIATED DEFIBRILLATOR FAILED TO DISCHARGE USING THE ATTACHED ELECTRODE PADS. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER DEVICE TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11664515 ↗
  • MalfunctionJan 3, 2020Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT DURING FUNCTIONAL TESTING, THE ASSOCIATED DEVICE WAS UNABLE TO CAPTURE PACING USING THESE ELECTRODE PADS. COMPLAINANT DID NOT INDICATE THAT THERE WAS ANY PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Patient Involvement

    MAUDE report 9545803 ↗
  • MalfunctionNov 12, 2019Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT DURING BIOMED TESTING, THE ASSOCIATED DEFIBRILLATOR DISPLAYED A "POOR PAD CONTACT" MESSAGE USING THESE ATTACHED ELECTRODE PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Patient Involvement

    MAUDE report 9311497 ↗
  • DeathSep 11, 2019Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (B)(6) YEAR OLD FEMALE PATIENT IN SEVERE BRADYCARDIA TRANSITIONED TO PEA, THE ASSOCIATED DEVICE DISPLAYED A ?CHECK PADS? MESSAGE USING THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THE CLINICIAN PERFORMED CPR TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THE PATIENT SUBSEQUENTLY EXPIRED.

    Patient problems: Death

    MAUDE report 8996541 ↗
  • MalfunctionMay 29, 2019Unable to Obtain Readings; Unable to Obtain Readings

    COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEFIBRILLATOR DISPLAYED A "POOR PAD CONTACT" MESSAGE WITH THESE ELECTRODES. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Patient Involvement

    MAUDE report 8651614 ↗
  • MalfunctionApr 26, 2019Packaging Problem; Packaging Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PATIENT (AGE AND GENDER UNKNOWN) THE ELECTRODES COULD NOT BE REMOVED FROM THE PACKAGING. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER ELECTRODE TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8557822 ↗
  • DeathApr 4, 2019Pacing Problem; Pacing Problem

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A (B)(6) YEAR-OLD FEMALE PATIENT, THE ASSOCIATED DEFIBRILLATOR FAILED TO PACE THE PATIENT WITH THESE ELECTRODE PADS. COMPLAINANT INDICATED THAT THE CLINICIAN OBTAINED ANOTHER DEVICE TO CONTINUE TREATING THE PATIENT. COMPLAINANT INDICATED THAT THE PATIENT SUBSEQUENTLY EXPIRED.

    Patient problems: Death

    MAUDE report 8484261 ↗
  • MalfunctionApr 17, 2018Device Displays Incorrect Message; Device Displays Incorrect Message

    COMPLAINANT ALLEGED THAT DURING A ROUTINE SHIFT CHECK BY A CLINICIAN, THE ASSOCIATED DEVICE DISPLAYED "DEFIB PAD SHORT" MESSAGE USING THESE ELECTRODES PADS. COMPLAINANT INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT IN THE REPORTED MALFUNCTION.

    Patient problems: No Patient Involvement

    MAUDE report 7437481 ↗
  • MalfunctionMar 29, 2018Device Packaging Compromised; Device Packaging Compromised

    COMPLAINANT ALLEGED THAT WHILE ATTEMPTING TO TREAT A PEDIATRIC PATIENT (GENDER UNKNOWN), THE ELECTRODE PADS WERE UNABLE TO BE REMOVED FROM THE PACKAGING. THE ELECTRODES SUBSEQUENTLY RIPPED CAUSING UNNECESSARY DELAY IN PATIENT CARE WHILE THE CLINICIAN APPLIED ECG LEADS TO CONTINUE CARDIAC MONITORING OF THE PATIENT. COMPLAINANT INDICATED THAT THERE WAS NO ADVERSE EFFECT TO THE PATIENT DUE TO THE REPORTED MALFUNCTION.

    Patient problems: No Information

    MAUDE report 7382478 ↗

Other Automated external defibrillators (non-wearable) devices

All Automated external defibrillators (non-wearable) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page