AMC LWM-329DS50/5ARecalls & reported problems
LifeSync Corporation · 5 Lead Disposable DIN to Pinch, Shld, 50” OM Combiner, AHA · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00849593016391), received between Aug 24, 2022 and Aug 22, 2023 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Device Sensing Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device Sensing Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 22, 2023
CVOR (CARDIOVASCULAR OPERATING ROOM): DURING PROCEDURE, AMC 5 LEAD CABLES WERE DIFFICULT TO ATTACH. CONNECTION WAS TIGHT INTO THE MAIN ECG CABLE. ECG WORKED FOR A SHORT TIME, THEN THE V LEAD DID NOT WORK. IT WOULD RETURN INTERMITTENTLY. ANOTHER CABLE USED WITHOUT FURTHER PROBLEMS. NO KNOWN HARM TO PATIENT, MINOR DELAY IN PROCEDURE. SAME DEVICE REPORTED YESTERDAY FOR THE SAME REASON. BOTH HAD THE SAME LOT #. MANUFACTURER RESPONSE FOR CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR), AMC (PER SITE REPORTER). WILL OBTAIN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17595024 ↗MalfunctionAug 17, 2023
CVOR (CARDIOVASCULAR OPERATING ROOM): DURING PROCEDURE, AMD 5 LEAD CABLES WERE DIFFICULT TO ATTACH. CONNECTION WAS TIGHT INTO THE MAIN ECG CABLE. ECG WORKED FOR A SHORT TIME, THEN THE V LEAD DID NOT WORK. IT WOULD RETURN INTERMITTENTLY. ANOTHER CABLE USED WITHOUT FURTHER PROBLEMS. NO KNOWN HARM TO PATIENT, MINOR DELAY IN PROCEDURE. MANUFACTURER RESPONSE FOR CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR), AMC (PER SITE REPORTER), WILL OBTAIN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17563169 ↗MalfunctionAug 24, 2022Device Sensing Problem
DURING PROCEDURE IN CARDIOVASCULAR OPERATING ROOM (CVOR), THE AMC 5 LEAD DISPOSABLE WAS USED. THE ONLY LEAD THAT GAVE A SIGNAL WAS III. THIS WAS ATTEMPTED 2 MORE TIMES, WITH 2 MORE DEVICES, WITH THE SAME RESULTS (ALL 3 DEVICES HAD THE SAME LOT NUMBER). MANUFACTURER RESPONSE FOR CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR), AMC (PER SITE REPORTER): WILL OBTAIN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15282367 ↗
Other Cable, Transducer And Electrode, Patient, (Including Connector) devices
- IntraSight 797403Philips Image Guided Therapy Corporation · Cable, Transducer And Electrode, Patient, (Including Connector)82 reports
- ASSY, CABLE, ECG, 15 LEAD, 3 WIRE PRECOR 11111Physio-Control, Inc. · CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR)1 recall0 reports
- MR Patient Care Short Wide ECG 2.0 Cable AAMI CAB,4 LD,CV MRI ECGPhilips Ds North America LLC · CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR)12 reports
- NA 5492ALMedtronic, Inc. · CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR)10 reports
- NA 5492VLMedtronic, Inc. · CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR)10 reports
- NA 5487LMedtronic, Inc. · CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR)8 reports
- NA 5487Medtronic, Inc. · CABLE, TRANSDUCER AND ELECTRODE, PATIENT, (INCLUDING CONNECTOR)6 reports
- CORE M2 Vascular System 400-0100.17Volcano Corporation · Cable, Transducer And Electrode, Patient, (Including Connector)6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page