Paladin 5.5x30Recalls & reported problems

Contego Medical, Inc. · The Paladin Carotid PTA Balloon System with Integrated Embolic Protection (IEP), is indicated for Percutaneous Transluminal Angioplasty (PTA) in the carotid arteries with capture and removal of embolic material · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00851616007293), received between Mar 13, 2026 and Mar 13, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Retraction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Retraction Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 13, 2026Retraction Problem

    EVENT DESCRIPTION A PALADIN PTA IEP SYS PD-5530-140-2 WAS ATTEMPTED TO BE USED BUT THE FILTER DIDN'T CLOSE ALL THE WAY. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. 17TH FEB 2026 ADDITIONAL INFORMATION RECEIVED FROM THE REP: THE DEVICE DID NOT HAVE ANY FILTER PREP. EACH TIME THEY WOULD RETRACT THE DEVICE BACK AFTER THE FILTER WAS CLOSED IT WOULD START TO OPEN AGAIN. THEY WERE ABLE TO PULL BACK A LITTLE CLOSE THE FILTER MORE UNTIL THE DEVICE WAS BACK INSIDE OF THE GUIDE CATHETER WHERE IT WAS REMOVED SAFELY. INVESTIGATION: THE INVESTIGATION CONFIRMED THAT THE FILTER OPENED AND CLOSED NORMALLY. THERE IS A POTENTIAL THAT THE CATHETER WAS BEING STRETCHED DURING REMOVAL ACCOUNTING FOR THE FRAME OPENING. THE INVESTIGATION IS ONGOING. CONCLUSIONS THE FAILURE COULD NOT BE REPLICATED ON THE RETURNED UNIT. THE RETURNED UNIT OPENED AND CLOSED NORMALLY. THIS COMPLAINT WAS FELT TO BE CLINICALLY INSIGNIFICANT AND WOULD BE CONSIDERED VERY LOW RISK TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24593708 ↗

Other Catheter, Angioplasty, Peripheral, Transluminal devices