Medical Information Technology, Inc. · MEDITECH's Blood Bank Software is a Blood Establishment Computer System (BECS) that tightly integrates donor, unit and patient history information with data in the Electronic Health Record (EHR). The software's significant performance characteristics are flagging abnormal test results, reporting test and transfusion results, minimizing product waste, utilizing expert rules when recording and performing error checks. It also generates turnaround time and workload statistics, compiles statistical reports, and automatically captures charges. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00863529000148), received between Dec 18, 2025 and Dec 18, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Application Program Problem: Parameter Calculation Error” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Application Program Problem: Parameter Calculation Error1
  • Improper or Incorrect Procedure or Method1
  • Program or Algorithm Execution Failure1

Patient problems

  • Hepatitis1
  • Transfusion Reaction1
  • Viral Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 18, 2025Application Program Problem: Parameter Calculation Error; Improper or Incorrect Procedure or Method; Program or Algorithm Execution Failure; Application Program Problem: Parameter Calculation Error; Improper or Incorrect Procedure or Method; Program or Algorithm Execution Failure

    THE ADVERSE EVENT (AE) INVOLVED A USER CONFIGURATION ERROR INVOLVING MEDICAL INFORMATION TECHNOLOGY, INC.'S EXPANSE BLOOD BANK APPLICATION THAT RESULTED IN A PATIENT RECEIVING A CONTAMINATED UNIT OF BLOOD, SPECIFICALLY A UNIT THAT TESTED REACTIVE FOR THE HEPATITIS B VIRUS NAT TEST. THE HOSPITAL ((B)(6)) HAD RECENTLY IMPLEMENTED NEW PROCEDURES FOR DONOR BLOOD SCREENING WHICH INCLUDED NUCLEIC ACID TESTING (NAT). DUE TO THE HOSPITAL'S IMPROPER CONFIGURATION OF THE TEST DICTIONARY AND DEFICIENT BLOOD BANK CALCULATIONS, THE AUTOMATED SAFEGUARDS THAT SHOULD HAVE PROTECTED THE PATIENT FAILED. THIS FAILURE MEANT THE CONTAMINATED BLOOD UNIT WAS NOT PROPERLY MARKED AS "CONTAMINATED" OR REMOVED FROM CIRCULATION, REMAINING AVAILABLE FOR PATIENT ASSIGNMENT, AND WAS SUBSEQUENTLY TRANSFUSED TO A PATIENT, RESULTING IN HARM. ALTHOUGH 32 CONTAMINATED UNITS WERE FOUND AT THE ORGANIZATION, ONLY ONE PATIENT WAS HARMED. THE FAILURE WAS ULTIMATELY ATTRIBUTED TO SETUP AND VALIDATION ERRORS BY THE CUSTOMER.

    Patient problems: Hepatitis; Transfusion Reaction; Viral Infection

    MAUDE report 23843359 ↗