Skip to content

Sunquest Blood Bank 11.0.2Recalls & reported problems

CliniSys, Inc · Blood Bank is intended for use by trained health care professionals responsible for transfusion services. It is intended to: • Record testing results of patient specimens and blood products either manually or through instrument interfaces. • Maintain a historical record of the patient’s blood bank and transfusion related data. • Display data required to assist health care professionals when qualifying patients for electronic crossmatch. • Store records of manufactured and blood product component preparation. • Record the release of manufactured and blood products for infusion. • Maintain manufactured and blood product inventory for lookback. • Print ISBT 128 blood product labels for finished and further processed blood products and products intended for transfer. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI B236BB11020), received between Apr 17, 2025 and Apr 17, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Patient Data Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Data Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 17, 2025Patient Data Problem; Patient Data Problem

    CLINISYS RECENTLY IDENTIFIED AN ISSUE INVOLVING BLOOD BANK WITH SUNQUEST INSTRUMENT MANAGER (SIM). THE ISSUE OCCURS WHEN A LABORATORY INSTRUMENT SENDS AN INCOMPLETE MESSAGE FOR A SAMPLE. THIS TRIGGERS A READ TIMEOUT IN OUR SIM OVISION_F DRIVER AFTER 30 SECONDS, RESULTING IN A "TIMED OUT" ERROR MESSAGE FOR THAT INITIAL SAMPLE. HOWEVER, THE DRIVER CAN RETAIN THE PARTIAL DATA TRANSFER IN MEMORY, LEADING TO POTENTIAL DATA MERGING WITH THE SUBSEQUENT SAMPLE'S TRANSMISSION. THERE HAVE BEEN NO INSTANCES OF HARM TO PATIENTS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21861540 ↗

Other Blood Establishment Computer Software And Accessories devices

All Blood Establishment Computer Software And Accessories devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page