Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00875197006391), received between Oct 31, 2024 and Oct 31, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Non Reproducible Results” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Non Reproducible Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 31, 2024Non Reproducible Results; Non Reproducible Results
THERE WAS AN ALLEGATION OF QUESTIONABLE FALSE POSITIVE COBAS® HCV (192T) RESULTS FOR 2 PATIENT PLASMA SAMPLES TESTED ON THE COBAS 8800 ANALYZER. PATIENT 1 INITIAL RESULT WAS 2.27E+001 IU/ML (HCV DETECTED). ON (B)(6) 2024, THE REPEAT RESULT FROM A NEW SAMPLE COLLECTED (B)(6) 202 WAS TARGET NOT DETECTED. ON (B)(6) 2024, A NEW SAMPLE WAS COLLECTED AND ANTIBODY TESTING FOR HCV WAS NEGATIVE. PATIENT 2 INITIAL RESULT WAS 3.30E+001 IU/ML (HCV DETECTED). ON (B)(6) 2024, A NEW SAMPLE WAS COLLECTED AND ANTIBODY TESTING FOR HCV WAS NEGATIVE. ON (B)(6) 2024, A NEW SAMPLE WAS COLLECTED AND ANTIBODY TESTING FOR HCV WAS NEGATIVE. ON (B)(6) 2024, THE REPEAT RESULT FROM A NEW SAMPLE COLLECTED (B)(6) 2024 WAS TARGET NOT DETECTED. THE RESULTS WERE REPORTED AS INDETERMINATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20580028 ↗
Other Assay, hybridization and/or nucleic acid amplification for detection of hepatitis c rna,hepatitis c virus devices
- Alinity m 08N50-095Abbott Molecular Inc. · Assay, hybridization and/or nucleic acid amplification for detection of hepatitis c rna,hepatitis c virus1 recall1 report
- cobas 8800 System 05412722001Roche Diagnostics GmbH · ASSAY,HYBRIDIZATION AND/OR NUCLEIC ACID AMPLIFICATION FOR DETECTION OF HEPATITIS C RNA,HEPATITIS C VIRUS6 reports
- cobas 6800 System 05524245001Roche Diagnostics GmbH · ASSAY,HYBRIDIZATION AND/OR NUCLEIC ACID AMPLIFICATION FOR DETECTION OF HEPATITIS C RNA,HEPATITIS C VIRUS5 reports
- cobas® NHP Negative Control Kit 1.0Roche Diagnostics GmbH · ASSAY,HYBRIDIZATION AND/OR NUCLEIC ACID AMPLIFICATION FOR DETECTION OF HEPATITIS C RNA,HEPATITIS C VIRUS2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗