cobas 8800 System 05412722001Recalls & reported problems

Roche Diagnostics GmbH · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04015630935390), received between Sep 14, 2018 and Jan 13, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “False Positive Result” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • False Positive Result2
  • Incorrect, Inadequate or Imprecise Result or Readings2
  • Defective Device1
  • High Test Results1
  • Mechanical Problem1
  • Non Reproducible Results1
  • Optical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 13, 2026Non Reproducible Results

    THERE WAS AN ALLEGATION OF DISCREPANT WNV RESULTS WITH THE COBAS®WNV KIT (480T) FROM THE COBAS 8800 ANALYZER FOR A SINGLE PATIENT. ON (B)(6) 2025, THE INITIAL SAMPLE GENERATED A REACTIVE RESULT FOR WNV (CT 3.7). THE SAME SAMPLE FROM A DIFFERENT TUBE WAS TESTED ON THE SAME DAY AND GENERATED A NON-REACTIVE RESULT FOR WNV.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24051226 ↗
  • MalfunctionNov 6, 2025False Positive Result; Optical Problem; False Positive Result; Optical Problem

    THERE WAS AN ALLEGATION OF A QUESTIONABLE COBAS® WNV (192T) ASSAY RESULT FOR A DONOR PATIENT SAMPLE TESTED ON A COBAS 8800 ANALYZER. THE INITIAL RESULT WAS REACTIVE. THE SAMPLE WAS REPEATED TWICE AND THE RESULTS WERE NON-REACTIVE BOTH TIMES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23488024 ↗
  • MalfunctionOct 23, 2025False Positive Result; Incorrect, Inadequate or Imprecise Result or Readings; False Positive Result; Incorrect, Inadequate or Imprecise Result or Readings

    THERE WAS AN ALLEGATION OF A QUESTIONABLE COBAS® WNV - 480 ASSAY RESULT FOR A PATIENT SAMPLE TESTED ON COBAS® 8800 SYSTEM. THE INITIAL RESULT WAS REACTIVE. THE SAMPLE WAS REPEATED TWICE AND THE RESULTS WERE NON-REACTIVE BOTH TIMES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23369455 ↗
  • MalfunctionOct 20, 2023Mechanical Problem; Mechanical Problem

    THERE WAS AN ALLEGATION OF AN ISSUE WITH THE FRONT COVER OF THE COBAS 8800 ANALYZER. THE CUSTOMER ALLEGED THE SAMPLE SUPPLY MODULE FRONT COVER SLAMMED SHUT ON AN OPERATOR'S LEFT INDEX FINGER. THE FIELD APPLICATION SPECIALIST CONFIRMED THE OPERATOR'S FINGER WAS BRUISED AND THE COVER WAS REPORTEDLY NOT SHUTTING SLOWLY AS EXPECTED. THE OPERATOR ALLEGEDLY DID NOT REQUIRE ANY MEDICAL TREATMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17978110 ↗
  • MalfunctionJan 3, 2022High Test Results; High Test Results

    A CUSTOMER FROM THE US ALLEGED (B)(6) DISCREPANT RESULTS GENERATED FOR ONE PATIENT WHEN USING THE COBAS 8800 SYSTEM (SN# (B)(4)). THE PATIENT SAMPLE PRODUCED A (B)(6) RESULT IN THE INITIAL TESTING. THIS SAMPLE WAS REFLEXED FOR (B)(6) GENOTYPE TESTING, PER NORMAL LAB PROCESS, WHERE IT RECEIVED A (B)(6) RESULT. THE SAMPLE WAS REPEATED ON ANOTHER 8800 SYSTEM AND RECEIVED A TARGET NOT DETECTED RESULT. BOTH THE INITIAL AND RETEST RESULTS WERE REPORTED OUT. NO HARM WAS ALLEGED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13144051 ↗
  • MalfunctionSep 14, 2018Incorrect, Inadequate or Imprecise Result or Readings; Defective Device

    A (B)(6) CUSTOMER ALLEGED DISCREPANT (B)(6) RESULTS FOR PATIENT SAMPLES TESTED WITH THE COBAS® HBV TEST FOR USE ON THE COBAS® 6800/8800 SYSTEMS. THE ROCHE FIELD SERVICE ENGINEER VISITED THE CUSTOMER SITE AND FOUND A FAILED RESULT FOR PROCESS HEAD TIGHTNESS CHECK WITH SOME LOOSE STOP DISCS ON THE COBAS 8800 SYSTEM'S PROCESSING TRANSFER HEADS, THAT COULD HAVE CAUSED THE ALLEGED DISCREPANT RESULTS. NO HARM OR INJURY WAS REPORTED THROUGH THE CASE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7878750 ↗

Other ASSAY,HYBRIDIZATION AND/OR NUCLEIC ACID AMPLIFICATION FOR DETECTION OF HEPATITIS C RNA,HEPATITIS C VIRUS devices

All ASSAY,HYBRIDIZATION AND/OR NUCLEIC ACID AMPLIFICATION FOR DETECTION OF HEPATITIS C RNA,HEPATITIS C VIRUS devices →