- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00880304461130), received between Jan 6, 2026 and Jan 6, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Difficult to Insert” (1 report).
6 other recalls cover devices cleared under the same FDA submission (K060692); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Insert1
- Difficult to Remove1
- Inadequacy of Device Shape and/or Size1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 6, 2026Difficult to Insert; Difficult to Remove; Inadequacy of Device Shape and/or Size
IT WAS REPORTED THAT DURING A COMPREHENSIVE SHOULDER ARTHROPLASTY, A SIZE 11 HUMERAL STEM COULD NOT BE ADVANCED AND BECAME STUCK INTRA-OPERATIVELY. DURING THE PROCEDURE, THE HUMERUS WAS REAMED FOR A SIZE 11 STANDARD STEM AND RASPED WITH A SIZE 11 HUMERAL RASP. THE IMPLANTED SIZE 11 PROSTHESIS COULD NOT ADVANCE BY APPROXIMATELY 1 CM AND COULD NEITHER BE FULLY INSERTED NOR REMOVED. AFTER APPROXIMATELY 2 HOURS OF UNSUCCESSFUL ATTEMPTS TO ADJUST OR REMOVE THE STEM, THE PROXIMAL HUMERUS WAS SPLIT TO FACILITATE REMOVAL, AND A SIZE 10 STEM WAS SUBSEQUENTLY IMPLANTED SUCCESSFULLY. THE PATIENT WAS IMPLANTED WITH A SIZE 10 HUMERAL STEM SUCCESSFULLY. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Insufficient Information
MAUDE report 23976057 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K060692. One submission often covers many models, so check the product and lot details in each record.
- Z-1543-2020 · Feb 17, 2020 · TerminatedComprehensive Shoulder System Mini Humeral Stem 9mm,, Model No. 113629 - Product Usage: The intended use of the comprehensive humeral stem mini is to act as the humeral component o
- Z-0591-2019 · Oct 10, 2018 · TerminatedComprehensive Mini Stem, Item No. 113631:
- Z-0980-2018 · Dec 8, 2017 · TerminatedHumeral Stem 55mm(Size 13) Product Usage: Intended for primary and revision total shoulder arthroplasty as well as hemi-arthroplasty
- Z-0979-2018 · Dec 8, 2017 · TerminatedHumeral Stem 83mm(Size 17) Product Usage: Intended for primary and revision total shoulder arthroplasty as well as hemi-arthroplasty
- Z-0299-2018 · Jun 5, 2017 · TerminatedCOMP PRIMARY STEM 8MM MINI, model # 113628
- Z-1755-2015 · Apr 16, 2015 · TerminatedComprehensive Shoulder System, 4 mm, 122 mm long, Primary Shoulder Stem, Ti-6Al-4V, Standard Length Porous Plasma. Shoulder joint replacement components include humeral stems, hum
Other PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices
- DJO SURGICAL 509-02-032Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED364 reports
- DELTA XTEND 130790036Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED171 reports
- DELTA XTEND 130770018Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED159 reports
- TRIGEN 71118200Smith & Nephew, Inc. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED123 reports
- DJO SURGICAL 509-02-432Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED119 reports
- DELTA XTEND 130738206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED116 reports
- COMPREHENSIVE SHOULDER SYSTEM 113633Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED2 recalls4 reports
- DELTA XTEND 130742206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED99 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page