LIFEPAK® 500 Automated External Defibrillator 99401 (REF 99401-001084)Recalls & reported problems
Physio-Control, Inc. · LP500AACBAZZZZZLP500GGCGIAAAAAAAAFAA · Class 3
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 3
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00885074753980), received between Mar 18, 2019 and Sep 17, 2019 — classified as 3 deaths, 1 malfunction.
The most frequently reported specific device problem is “Connection Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Connection Problem3
- Impedance Problem1
- Improper or Incorrect Procedure or Method1
Patient problems
- Death3
- No Patient Involvement1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
DeathSep 17, 2019Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method
THE CUSTOMER CONTACTED PHYSIO-CONTROL TO REPORT THAT A USE ERROR OF SELECTING THE POWER BUTTON INSTEAD OF THE ANALYSE BUTTON CAUSED A 2 MINUTE DELAY IN CARE AND MAY HAVE CAUSED OR CONTRIBUTED TO A PATIENT DEATH.
Patient problems: Death
MAUDE report 9078793 ↗DeathAug 9, 2019Connection Problem; Impedance Problem; Connection Problem; Impedance Problem
THE CUSTOMER CONTACTED PHYSIO-CONTROL TO REPORT THAT THEY WERE USING THIS DEVICE ON A PATIENT AND IT DISPLAYED A ¿CONNECT ELECTRODES¿ MESSAGE. THIS LED TO OVER A 6 MINUTE DELAY IN THE TREATMENT OF THE PATIENT. AS A RESULT, DEFIBRILLATION THERAPY MAY HAVE BEEN DELAYED OR UNAVAILABLE, IF IT WAS NEEDED. THE PATIENT INVOLVED IN THE REPORTED EVENT IS DECEASED.
Patient problems: Death
MAUDE report 8880615 ↗DeathAug 9, 2019Connection Problem; Connection Problem
THE CUSTOMER CONTACTED PHYSIO-CONTROL TO REPORT THAT THEY WERE USING THIS DEVICE ON A PATIENT AND IT DISPLAYED A CONNECT ELECTRODES¿ MESSAGE. THIS LED TO OVER A 6 MINUTE DELAY IN THE TREATMENT OF THE PATIENT. AS A RESULT, DEFIBRILLATION THERAPY MAY HAVE BEEN DELAYED OR UNAVAILABLE, IF IT WAS NEEDED. THE PATIENT INVOLVED IN THE REPORTED EVENT IS DECEASED.
Patient problems: Death
MAUDE report 8878773 ↗MalfunctionMar 18, 2019Connection Problem; Connection Problem
THE CUSTOMER CONTACTED PHYSIO-CONTROL TO REPORT THAT THEIR DEVICE WOULD NOT RECOGNIZE A PATIENT CONNECTION. THE DEVICE CONTINUED TO GIVE THE CONNECT ELECTRODES PROMPT EVEN AFTER THE ELECTRODES WERE PROPERLY ATTACHED TO THE PATIENT. THE CUSTOMER REPORTED THAT THE PATIENT EXPIRED; HOWEVER, IT WAS NOT DUE TO THE REPORTED ISSUE. THE PATIENT HAD A DO NOT RESUSCITATE ORDER.
Patient problems: No Patient Involvement
MAUDE report 8430180 ↗
Other Automated external defibrillators (non-wearable) devices
- NA 861290Philips Medical Systems Hsg · Automated External Defibrillators (Non-Wearable)12 deaths5,167 reports
- NA 861288Philips Medical Systems Hsg · Automated External Defibrillators (Non-Wearable)21 deaths5,015 reports
- NA 861289Philips Medical Systems Hsg · Automated External Defibrillators (Non-Wearable)7 deaths3,385 reports
- R SERIES 30001005201310012Zoll Medical Corporation · Automated external defibrillators (non-wearable)10 deaths1,720 reports
- PHILIPS HeartStart FRxPhilips Electronics North America Corporation · Automated external defibrillators (non-wearable)26 deaths1,586 reports
- LIFEPAK CR2 99512Physio-Control, Inc. · Automated external defibrillators (non-wearable)8 deaths1,502 reports
- Lifeline Configuration DDU-100ADefibtech, L.L.C. · Automated External Defibrillators (Non-Wearable)1 death1,285 reports
- PHILIPS HeartStart FR3Philips Electronics North America Corporation · Automated External Defibrillators (Non-Wearable)10 deaths1,188 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page