AETOS Shoulder System DRL-0990-849SRecalls & reported problems
Smith & Nephew, Inc. · CENTRAL POST DRILL BIT · Class 1
All models of AETOS Shoulder System (44)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00885556871348), received between Sep 18, 2023 and Sep 18, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Nonstandard Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Nonstandard Device1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 18, 2023Nonstandard Device; Adverse Event Without Identified Device or Use Problem; Nonstandard Device; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, DURING REVERSE SHOULDER ARTHROPLASTY, UTILIZING ONE (1) 10MM BASEPLATE AND A CENTRAL POST EXTENSION DRILL BIT, THE BASEPLATE WAS TIGHT GOING IN TO THE GLENOID AND CRACKED THE GLENOID DURING IMPACTION OF THE BASEPLATE. THE PROCEDURE WAS RESUMED , AFTER A NON-SIGNIFICANT DELAY WITH THE SAME DEVICE. HEALTH STATUS OF THE PATIENT IS UNKNOWN.
Patient problems: Bone Fracture(s)
MAUDE report 17764287 ↗
Other BIT, DRILL devices
- QUICKSET 2274-25-500Depuy Orthopaedics, Inc. · BIT, DRILL1,985 reports
- QUICKSET 2274-35-500Depuy Orthopaedics, Inc. · BIT, DRILL770 reports
- QUICKSET 2274-30-500Depuy Orthopaedics, Inc. · BIT, DRILL761 reports
- NA 03.037.022Synthes GmbH · BIT, DRILL339 reports
- NA 323.062Synthes GmbH · BIT, DRILL309 reports
- QUICKSET 2274-56-000Depuy (Ireland) · BIT, DRILL275 reports
- QUICKSET 2274-45-500Depuy Orthopaedics, Inc. · BIT, DRILL211 reports
- LCS 2366-83-000Depuy (Ireland) · BIT, DRILL207 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.