N/A (REF B12LT)Recalls & reported problems
Stryker Sustainability Solutions, Inc. · Bladeless Trocar w/Stability Sleeve · Class 2
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00885825020897), received between Oct 24, 2024 and Apr 21, 2025 — classified as 2 injuries.
The most frequently reported specific device problem is “Fracture” (2 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Recalls naming this device
- Aug 19, 2026Open, Classified
Reusable access port system may crack or seperate during use.
Z-3185-2026 · Root cause: Device Design · FDA record ↗
Most reported problems
Device problems
- Fracture2
Patient problems
- Foreign Body In Patient2
- Insufficient Information1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 21, 2025Fracture; Fracture
IT WAS REPORTED THAT WHEN PERFORMING A THORACOSCOPIC LUNG DECORT/VATS AND REMOVING THE SIZE 12 TROCAR, THE TROCAR SLEEVE BROKE INTO PIECES. AS REPORTED, SOME PIECES WENT INSIDE OF THE PATIENT. ALL PIECES WERE RETRIEVED EXCEPT FOR PIECES THAT WERE TOO SMALL TO SEE. THERE WERE NO SAMPLES AVAILABLE FOR INVESTIGATION. AN X-RAY WAS NOT USED TO LOCATE THE PIECES AND A LARGER INCISION WAS NOT MADE TO RETRIEVE THE BROKEN PIECES. THERE WAS NO OTHER PATIENT INJURY REPORTED AND THERE WAS NO MEDICAL INTERVENTION OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Foreign Body In Patient
MAUDE report 21874663 ↗InjuryOct 24, 2024Fracture; Fracture
IT WAS REPORTED THAT THE TROCAR HAD A BROKEN TIP. AS REPORTED, THE MISSING PART COULD NOT BE FOUND ON X-RAY AND THE SURGEON DID NOT NOTICE IF THE BROKEN TIP WAS ALREADY THERE BEFORE THE INTRODUCTION. NO OTHER INFORMATION WAS PROVIDED REGARDING PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Foreign Body In Patient; Insufficient Information
MAUDE report 20529084 ↗
Other LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED devices
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED1 recall17 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED1 recall16 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED1 recall3 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED1 recall0 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED1 recall0 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED1 recall0 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED13 reports
- N/AStryker Sustainability Solutions, Inc. · LAPAROSCOPE, GENERAL & PLASTIC SURGERY, REPROCESSED7 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.