Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00886333225477), received between Oct 4, 2022 and Oct 4, 2022 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1
  • Leak/Splash1

Patient problems

  • Pneumothorax1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 4, 2022Break; Leak/Splash

    DRAINAGE CATHETER BROKE AT THE WHITE HUB, DUE TO THE LEAK THE PATIENT HAD A PNEUMOTHORAX. CONNECTING TUBE 404343015, LOT 11410970. REPORT FOR THIS ITEM HAS BEEN PROVIDED AS WELL.

    Patient problems: Pneumothorax

    MAUDE report 15536294 ↗

FDA clearance and classification

The FDA regulates product code GBO (catheter, nephrostomy, general & plastic surgery) under 21 CFR 878.4200 as a Class I device. 21 CFR 878.4200 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020

Has the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00886333225477), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 4, 2022. That report lists device problems “Break” (1) and “Leak/Splash” (1); patient problem “Pneumothorax” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020 FDA approved?

Devices of this type (product code GBO) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Argon Medical Devices, Inc.

Is the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the SKATER™ All-Purpose and Nephrostomy Drainage Set 756106020, and is it still sold?

The FDA's device database lists Argon Medical Devices, Inc. as the company responsible for it (brand SKATER™ All-Purpose and Nephrostomy Drainage Set, model 756106020). Its record shows it as in commercial distribution.