None 372011Recalls & reported problems
Intuitive Surgical, Inc. · ENDOSCOPE · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00886874110454), received between May 6, 2023 and May 27, 2023 — classified as 9 malfunctions.
The most frequently reported specific device problem is “Break” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break5
- Detachment of Device or Device Component5
- Failure to Calibrate1
- Fogging1
- Material Separation1
- Optical Distortion1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 27, 2023Material Separation; Material Separation
IT WAS REPORTED THAT THE ENDOSCOPE HAD CLOUDY IMAGE ISSUES PRIOR TO STARTING THE DA VINCI-ASSISTED PROCEDURE. A SPARE SCOPE WAS USED FOR THE PROCEDURE. THE DEFECTIVE SCOPE WAS NOT USED ON THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17015673 ↗MalfunctionMay 21, 2023Break; Break
IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED BILATERAL INGUINAL HERNIA PROCEDURE, THE SCOPE WOULD NOT PASS THE BALANCE TEST. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORT OF PATIENT HARM, ADVERSE OUTCOME OR INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16971289 ↗MalfunctionMay 21, 2023Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE REPORTER COMPLAINED THAT THE GLASS OF THE ENDOSCOPE WAS NOT AT THE TIP AND A SPARE ENDOSCOPE WAS USED. THE LENS WAS ALSO CLOUDY. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16971207 ↗MalfunctionMay 21, 2023Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO STARTING THE DA VINCI-ASSISTED PROCEDURE THE CUSTOMER HAD CALIBRATION ISSUES ON THE SCOPE. THERE WAS NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16971205 ↗MalfunctionMay 6, 2023Break; Fogging; Detachment of Device or Device Component; Break; Fogging; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE 30 DEGREE ENDOSCOPE WHITE BALANCE WAS FOGGY AND WAS FOUND WITH SMUDGING AND MOISTURE UNDER THE SCOPE LENS. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16883630 ↗MalfunctionMay 6, 2023Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO A DA VINCI-ASSISTED SURGICAL PROCEDURE, A GLASS LENS OF AN ENDOSCOPE WAS MISSING. THERE WAS NO REPORT OF PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16883618 ↗MalfunctionMay 6, 2023Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING CENTRAL PROCESSING THAT, THE ENDOSCOPE HAD A FOGGING ISSUE AND WAS MISSING LENS. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED-UP AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION ABOUT THE COMPLAINT: THE ISSUE WAS DISCOVERED DURING CENTRAL PROCESSING, BUT THE ENDOSCOPE WAS NOT DAMAGED DURING CENTRAL PROCESSING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16883293 ↗MalfunctionMay 6, 2023Failure to Calibrate; Failure to Calibrate
IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE 30-DEGREE ENDOSCOPE WOULD NOT CALIBRATE. A SPARE ENDOSCOPE WAS USED TO RESOLVE THE ISSUE. THE PROCEDURE WAS COMPLETED AS PLANNED. THE ENDOSCOPE WAS NOT USED ON A PATIENT AT THE TIME THE ISSUE WAS IDENTIFIED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16883289 ↗MalfunctionMay 6, 2023Optical Distortion; Optical Distortion
IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE ENDOSCOPE HAD BLURRY IMAGE ISSUES AND HAD A MISSING LENS. THE PROCEDURE WAS COMPLETED WITH A SPARE ENDOSCOPE WITH NO REPORTED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16883284 ↗
Other System,surgical,computer controlled instrument devices
- EndoWrist 471205Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall14,225 reports
- EndoWrist 470179Intuitive Surgical, Inc. · System,surgical,computer controlled instrument2 recalls2 deaths10,156 reports
- EndoWrist 471093Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall8,581 reports
- EndoWrist 471172Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall1 death6,302 reports
- daVinci Xi 380652Intuitive Surgical, Inc. · System,surgical,computer controlled instrument2 recalls235 deaths5,316 reports
- daVinci Xi 381121Intuitive Surgical, Inc. · System,surgical,computer controlled instrument1 recall2 deaths4,310 reports
- EndoWrist 471405Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall1 death3,770 reports
- EndoWrist 470327Intuitive Surgical, Inc. · System,surgical,computer controlled instrument2 recalls2,273 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page