None 470067Recalls & reported problems

Intuitive Surgical, Inc. · ENDOSCOPE · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This da Vinci endoscope from Intuitive Surgical is the camera used in da Vinci-assisted surgery. The FDA records hold 97 reports, with no deaths and no injuries; most describe the camera image flipping or appearing upside down during procedures, which staff sometimes fixed by reinstalling the scope, restarting the system or replacing it. Some also mention cracks and unexpected shutdowns. Reports rose to 65 in the last 12 months from 31 in the prior 12 months. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
93
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 93 adverse event reports that list this exact device (DI 00886874120286), received between Jun 28, 2024 and Sep 25, 2026 — classified as 93 malfunctions.

The most frequently reported specific device problem is “Image Orientation Incorrect” (79 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 3 reportsJul 2025: 9 reportsAug 2025: 5 reportsSep 2025: 6 reportsOct 2025: 4 reportsNov 2025: 7 reportsDec 2025: 6 reportsJan 2026: 8 reportsFeb 2026: 3 reportsMar 2026: 11 reportsApr 2026: 10 reportsMay 2026: 4 reportsJun 2026: 3 reportsJul 2026: 5 reportsAug 2026: 2 reportsSep 2026: 2 reportsOct 2026: 0 reportsNov 2026: 0 reports20242025202611
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Image Orientation Incorrect79
  • Material Integrity Problem3
  • No Apparent Adverse Event3
  • Crack2
  • Unexpected Shutdown2
  • Unintended Movement2
  • Break1
  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions80
  • Insufficient Information14

Recent adverse event reports

The 25 most recent of 93 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 25, 2026Image Orientation Incorrect

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50902397 ↗
  • MalfunctionSep 11, 2026No Apparent Adverse Event

    Patient problems: Insufficient Information

    MAUDE report 50744282 ↗
  • MalfunctionAug 11, 2026Detachment of Device or Device Component

    It was reported that during central processing with a 30-Degree Endoscope Plus, a piece on endoscope that attaches to the robot for use was separated from the viewing piece of the scope. There was no report of patient involvement or patient injury.

    Patient problems: Insufficient Information

    MAUDE report 50216253 ↗
  • MalfunctionAug 5, 2026Image Orientation Incorrect

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50138704 ↗
  • MalfunctionJul 31, 2026Image Orientation Incorrect

    It was reported that during a da Vinci-assisted radical with lymphadenectomy prostatectomy surgical procedure, the customer informed Intuitive Surgical, Inc. (ISI) Technical Support Engineer (TSE) that image orientation of 30-Degree Endoscope was flipped. The customer power cycled the system, which resolved the issue. The procedure was completing as planned with no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50103442 ↗
  • MalfunctionJul 28, 2026Image Orientation Incorrect

    It was reported that prior to starting a da Vinci-assisted surgical procedure, Endoscope did not change orientation. The customer reported event has no report of patient injury.

    Patient problems: Insufficient Information

    MAUDE report 50052216 ↗
  • MalfunctionJul 28, 2026Image Orientation Incorrect

    It was reported that during central processing, the Endoscope was stuck in 30 down orientation. There was no report of patient involvement.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50052213 ↗
  • MalfunctionJul 27, 2026Image Orientation Incorrect

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50047352 ↗
  • MalfunctionJul 27, 2026Image Orientation Incorrect

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50047350 ↗
  • MalfunctionJun 24, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE CAMERA SLIPPED AND WAS UPSIDE DOWN IN THE SURGEON CONSOLE. THEY HAD TO UNDOCK THE ROBOT AND RE-DOCK TO RESET IT. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25610312 ↗
  • MalfunctionJun 22, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THERE WAS AN ERROR CODE WHEN CHANGING THE ORIENTATION OF THE ENDOSCOPE. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) PERFORMED FOLLOW-UP AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION REGARDING THE REPORTED EVENT: THE REPORTED ISSUE WAS RESOLVED BY REPLACING THE ENDOSCOPE. IT WAS CONFIRMED THAT THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25580417 ↗
  • MalfunctionJun 2, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI ASSISTED PARAESOPHAGEAL HIATAL HERNIA SURGICAL PROCEDURE, INTUITIVE SURGICAL, INC. (ISI) CLINICAL TERRITORY ASSOCIATE (CTA) INFORMED TECHNICAL SUPPORT ENGINEER (TSE) THAT THE ENDOSCOPE IMAGE WAS FLIPPING. THE TSE EXPLAINED POTENTIAL CAUSES FOR THE ENDOSCOPE FLIPPING WHEN REINSTALLED ON THE ARM AFTER CLEANING. TSE REVIEWED THE SYSTEM LOGS AND OBSERVED THAT NO INSTRUMENTS WERE INSTALLED AT THAT TIME. THE TSE ADVISED THE CTA TO PERFORM A HARD POWER CYCLE AND TO MONITOR THE ISSUE FOR THE NEXT PROCEDURE. TSE ALSO PROVIDED GUIDANCE ON AN IN-PROCEDURE WORKAROUND BY CANCELLING THE GUIDE TOOL CHANGE (GTC) TO RESTORE PROPER IMAGE ORIENTATION. THE PROCEDURE WAS COMPLETING AS PLANNED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25364492 ↗
  • MalfunctionMay 29, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED COLOSTOMY CLOSURE SURGICAL PROCEDURE, THE CUSTOMER ENCOUNTERED AN ISSUE WITH THE CAMERA HORIZON. THE CUSTOMER REPORTED THAT THE HORIZON WAS CORRECT ON THE VISION SIDE CART (VSC) AND MATCHED THE PHYSICAL ORIENTATION OF THE 30-DEGREE ENDOSCOPE, BUT THE HORIZON AT THE SURGEON SIDE CONSOLE (SSC) WAS INCORRECT. INTUITIVE SURGICAL, INC. (ISI) TECHNICAL SUPPORT ENGINEER (TSE) RECOMMENDED RESEATING THE ENDOSCOPE AND REBOOTING THE SYSTEM IF THE ISSUE PERSISTED. THE PROCEDURE WAS COMPLETING AS PLANNED WITH NO REPORTED INJURY. ISI FOLLOWED UP WITH THE CSR AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE ENDOSCOPE MOVED FREELY WITH UNCONTROLLED MOTION. THE EVENT DID NOT INVOLVE A REVERSED CONTROL ON THE SYSTEM ARMS, ONLY THE ENDOSCOPE POSITIONING WAS OFF. NO DAMAGE WAS OBSERVED ON THE ENDOSCOPE¿S ADAPTER/BASE. THE ENDOSCOPE WAS UNPLUGGED AND PLUGGED BACK IN, AND A SYSTEM RESTART WAS PERFORMED; HOWEVER, THE ISSUE PERSISTED. THE CASE WAS COMPLETED WITH THE SAME ENDOSCOPE. CUSTOMER RESEATED AND CANCELLED GUIDED TOOL CHANGE TO FULLY RESET THE POSITION, BUT THE ERROR STILL OCCURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25333189 ↗
  • MalfunctionMay 20, 2026Material Integrity Problem

    IT WAS REPORTED THAT 30-DEGREE ENDOSCOPE WAS FOUND BROKEN, AND A SYSTEM ERROR APPEARED. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25235690 ↗
  • MalfunctionMay 19, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE CAMERA IMAGE FROM A 30-DEGREE ENDOSCOPE HAD AN INVERTED IMAGE, BUT AFTER A POWER CYCLE, THE IMAGE WAS CORRECTED. THE PROCEDURE WAS COMPLETING AS PLANNED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THERE WAS NO UNCONTROLLED MOTION. THE EVENT DID NOT INVOLVE REVERSED CONTROLS. THE POWER WENT OUT AND WHEN IT CAME BACK, THE VIEW WAS BACKWARDS AND UPSIDE DOWN. THERE WAS NO DAMAGE OBSERVED ON THE ENDOSCOPE¿S ADAPTER/BASE. PRIOR TO THE EVENT THE ENDOSCOPE WAS MANUALLY ROTATED 180 DEGREES. THE TEAM IS UNSURE IF THE SURGEON MANUALLY ASSOCIATED THE RIGHT AND LEFT CONTROLS WITH THE RESPECTIVE ARMS FOR INTUITIVE MOTION. THE PRODUCT WILL NOT BE RETURNED FOR EVALUATION. NO PHOTOS OR IMAGES WERE AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25220135 ↗
  • MalfunctionMay 7, 2026Unexpected Shutdown

    IT WAS REPORTED THAT DURING A DA VINCI ASSISTED SURGICAL PROCEDURE, THE IMAGE ORIENTATION WAS FLIPPED. TECHNICAL SUPPORT GUIDED THE STAFF TO REMOVE THE ENDOSCOPE FROM THE ARM AND PRESS THE INSTRUMENT CLUTCH BUTTON TO CANCEL THE GUIDED TOOL CHANGE. THE STAFF THEN MANUALLY ROTATED THE ENDOSCOPE COLLAR AND SHAFT TO MATCH THE ORIENTATION SELECTED ON THE SYSTEM AND REINSTALLED THE ENDOSCOPE. THE USER CONFIRMED THAT THE IMAGE ORIENTATION WAS CORRECTED AND THE PROCEDURE CONTINUED. THE CUSTOMER REPORTED EVENT HAS NO REPORT OF PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25118632 ↗
  • MalfunctionApr 24, 2026Crack

    REFER TO H11 FOR FOLLOW-UP INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24990465 ↗
  • MalfunctionApr 24, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT THE OPERATING ROOM MANAGER STATED THAT, PRIOR TO THE START OF THE CASE, THE IMAGE APPEARED FLIPPED. THE SURGEON THEN RESTARTED THE SYSTEM, AFTER WHICH THE IMAGE RETURNED TO NORMAL AND NO FURTHER TROUBLESHOOTING WAS REQUIRED. THE CUSTOMER REPORTED EVENT HAS NO REPORT OF PATIENT INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER ON AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: NO SPECIFIC SCOPE OR INSTRUMENT IDENTIFIED, IT HAPPENED ON MULTIPLE CASES. THERE ARE NO PHOTOS FOR REVIEW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24982677 ↗
  • MalfunctionApr 22, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PANCREATODUODENECTOMY SURGICAL PROCEDURE, A CLINICAL SALES REPRESENTATIVE (CSR) CALLED TO REPORT A REFLECTION OF THE SURGICAL VIEW APPEARING ON THE 'CEILING' OF THE VIEWER WITH THE IMAGE BEING INVERSED. THE TECHNICAL SUPPORT ENGINEER (TSE) ADVISED REPLACING THE SCOPE AND POWER CYCLING THE SYSTEM. NO FAULTS WERE REPORTED BY THE SYSTEM. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24960192 ↗
  • MalfunctionApr 22, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT PRIOR TO START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE, IT WAS NOTED THAT THE ANGULATION WAS OFF. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24956921 ↗
  • MalfunctionApr 16, 2026Image Orientation Incorrect

    REFER TO H11 FOR FOLLOW-UP INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24903363 ↗
  • MalfunctionApr 14, 2026Image Orientation Incorrect

    REFER TO H11 FOR FOLLOW-UP INFORMATION.

    Patient problems: Insufficient Information

    MAUDE report 24875172 ↗
  • MalfunctionApr 8, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT THE OR STAFF CALLED IN DURING THE MIDDLE OF A PROCEDURE TO REPORT THAT WHEN THEY INITIALLY INSERTED THE ENDOSCOPE INTO THE CANNULA ON ARM 2, THE IMAGE INVERTED ON ITS OWN. THEY REMOVED THE CAMERA AND PLACED IT ON ARM 3 AND DID NOT HAVE ANY FURTHER ISSUES. IT WAS NOTED THAT THERE WERE NO ERRORS ASSOCIATED WITH THIS AND THE SCOPE WAS NOT ACCIDENTALLY MANUALLY ROTATED. THE TSE ADVISED THAT THERE COULD BE AN ISSUE WITH THE ENDOSCOPE AND SUGGESTED REPLACING IT IF THE ISSUE RETURNS. THE CUSTOMER REPORTED EVENT HAS NO REPORT OF PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24821393 ↗
  • MalfunctionApr 8, 2026No Apparent Adverse Event

    IT WAS REPORTED THAT PRIOR TO THE START OF A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE 8MM ENDOSCOPE, 30° WAS NOT WORKING. THE PROCEDURE WAS COMPLETING AS PLANNED WITH NO REPORTED INJURY. ISI FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THERE WAS NO MATERIAL MISSING/DETACHED FROM THE PORTION OF THE DEVICE THAT ENTERS THE PATIENT¿S BODY. NO HARM TO PATIENT. NO DETAILS WERE PROVIDED JUST THAT IT WAS NOT WORKING. IT WAS SET UP FOR USE BUT NOT USED IN THE OR AFTER ALL. GIVEN TO CSR FOR CLEANING AND THEN PROVIDED TO ME TO SEND OUT FOR REPAIR. NO PHOTOGRAPHIC IMAGES OR A VIDEO RECORDING OF THE PROCEDURE AVAILABLE. THE SCOPE WAS SHIPPED WHEN THE REPLACEMENT SCOPE ARRIVED. FROM THE CUSTOMER'S UNDERSTANDING, THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 24812549 ↗
  • MalfunctionApr 7, 2026Image Orientation Incorrect

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE CAMERA IMAGE APPEARED UPSIDE DOWN. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24799367 ↗

FDA clearance and classification

The FDA regulates product code NAY (system, surgical, computer controlled instrument) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗

Devices of this type normally need 510(k) clearance before sale.

Common questions about the None 470067

Has the None 470067 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00886874120286), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the None 470067?

The FDA's MAUDE database lists 93 adverse event reports for this device, received between Jun 28, 2024 and Sep 25, 2026. In those reports, the most common specific device problems are “Image Orientation Incorrect” (79), “Material Integrity Problem” (3) and “Crack” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the None 470067?

None of the reports are classified as deaths, 0 as injuries and 93 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the None 470067, and is it still sold?

The FDA's device database lists Intuitive Surgical, Inc. as the company responsible for it (brand None, model 470067). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other System, surgical, computer controlled instrument devices

All System, surgical, computer controlled instrument devices →