EndoWrist SP 430101Recalls & reported problems
Intuitive Surgical, Inc. · MONOPOLAR CAUTERY INSTRUMENT · Class 2
All models of EndoWrist SP (20)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00886874124147), received between Jul 9, 2025 and Sep 28, 2026 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Break” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break5
- Material Split, Cut or Torn1
- Unintended System Motion1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Insufficient Information2
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 28, 2026Break
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50925536 ↗MalfunctionSep 4, 2026Break
Patient problems: Insufficient Information
MAUDE report 50621963 ↗MalfunctionAug 20, 2026Break
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50356991 ↗MalfunctionFeb 9, 2026Material Split, Cut or Torn
IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE SINGLE PORT MONOPOLAR CAUTERY INSTRUMENT SHOWED A BLUE LIGHT, BUT DURING THE SURGERY, WHEN ATTEMPTING TO USE THE MONOPOLAR, AN ORANGE LIGHT APPEARED ON THE CORD AND INSTRUMENT. THE CUSTOMER UNPLUGGED AND RE-PLUGGED ALL THE CORDS AND REPLACED THEM WITH NEW ONES, BUT IT STILL DID NOT WORK, AND A 'REPLACE INSTRUMENT' ERROR MESSAGE APPEARED. EVEN AFTER REATTACHING THE INSTRUMENT, IT DID NOT FUNCTION, SO THEY REPLACED IT WITH A NEW INSTRUMENT, AFTER WHICH THE ENERGY COULD BE USED NORMALLY. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24288885 ↗MalfunctionDec 15, 2025Unintended System Motion; Unintended System Motion
IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED RADICAL TONSILLECTOMY SURGICAL PROCEDURE, THE SINGLE PORT MONOPOLAR CAUTERY INSTRUMENT WAS "OUT OF ALIGNMENT" WHILE USING THE ROBOT; IT MOVED THE WRONG WAY. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23811500 ↗MalfunctionNov 27, 2025Break; Break
IT WAS REPORTED THAT AFTER A DA VINCI-ASSISTED PROSTATECTOMY-SIMPLE TRANSVESICAL SURGICAL PROCEDURE, SINGLE PORT (SP) MONOPOLAR CAUTERY INSTRUMENT TIP BROKE OFF AFTER THE PROCEDURE WHEN THE SURGICAL TECH WAS REMOVING THE SPATULA TIP. THE SPATULA TIP WAS THROWN AWAY BY THE TECH. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE FOLLOWED UP AND OBTAINED ADDITIONAL INFORMATION. THE INSTRUMENT WAS INSPECTED PRIOR TO USE. THE SURGICAL TASK WAS BEING PERFORMED WHEN THE ISSUE OCCURRED WAS THE SURGICAL TECH WAS REMOVING THE SPATULA TIP FROM INSTRUMENT WHEN IT BROKE OFF, SAID SHE DIDN¿T THINK TO SAVE THE SPATULA TIP FOR ANALYSIS AND THREW IT AWAY. THE CONTACT PERSON DID NOT BELIEVE THE INSTRUMENT DID NOT COLLIDE WITH ANY OTHER INSTRUMENT. THE INCIDENT DID NOT INVOLVE A FRAGMENT FALLING INSIDE THE PATIENT. THERE WERE NO TESTS LIKE AN X-RAY OR ULTRASOUND PERFORMED TO CHECK FOR REMAINING FRAGMENTS. THE PATIENT HAS NOT RETURNED TO THE HOSPITAL DUE TO THE EXPERIENCING ANY COMPLICATION RELATED TO RETAINING A FOREIGN OBJECT. PATIENT DEMOGRAPHICS WERE NOT PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23663494 ↗MalfunctionJul 9, 2025Break; Break
IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED RADICAL TONSILLECTOMY SURGICAL PROCEDURE, THE SINGLE PORT (SP) MONOPOLAR CAUTERY INSTRUMENT HAD A SPLIT AT THE TIP. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY.
Patient problems: Insufficient Information
MAUDE report 22463121 ↗
Other System, surgical, computer controlled instrument devices
- EndoWrist 471205Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall14,225 reports
- EndoWrist 470179Intuitive Surgical, Inc. · System,surgical,computer controlled instrument2 recalls2 deaths10,156 reports
- EndoWrist 471093Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall8,581 reports
- EndoWrist 471172Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall1 death6,302 reports
- daVinci Xi 380652Intuitive Surgical, Inc. · System,surgical,computer controlled instrument2 recalls235 deaths5,316 reports
- daVinci Xi 381121Intuitive Surgical, Inc. · System,surgical,computer controlled instrument1 recall2 deaths4,310 reports
- EndoWrist 471405Intuitive Surgical, Inc. · System, surgical, computer controlled instrument1 recall1 death3,770 reports
- EndoWrist 470327Intuitive Surgical, Inc. · System,surgical,computer controlled instrument2 recalls2,273 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page