Skip to content

PCM 7680265Recalls & reported problems

Nuvasive, Inc. · Artificial Vertebral Disc, 6.5mm Small · Class 3 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00887517081124), received between Oct 26, 2015 and Nov 22, 2016 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Loose or Intermittent Connection1
  • Migration or Expulsion of Device1

Patient problems

  • Failure of Implant2
  • Fall1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 22, 2016Migration or Expulsion of Device; Migration or Expulsion of Device

    ON (B)(6) 2016, A (B)(6)FEMALE UNDERWENT ANTERIOR CERVICAL DISCECTOMY AND IMPLANTATION OF A PROSTHETIC DEVICE. AROUND 3 MONTHS POST-OPERATIVELY, IT WAS REPORTED THE PATIENT FELL AND THE CAUDAL PORTION OF THE DEVICE MIGRATED ANTERIORLY. A REVISION SURGERY WAS PERFORMED (B)(6) 2016. THE DEVICE WAS EXPLANTED AND THE PATIENT RECEIVED AN ACDF.

    Patient problems: Failure of Implant; Fall

    MAUDE report 6121939 ↗
  • MalfunctionOct 26, 2015Loose or Intermittent Connection

    ON (B)(6), 2013, A PATIENT UNDERWENT A SINGLE LEVEL CERVICAL ARTHROPLASTY AT C5-6. APPROXIMATELY 30 MONTHS POSTOPERATIVE, THE PATIENT REPORTED NEW SYMPTOMS OF SIGNIFICANT NECK PAIN, BILATERAL ARM PAIN, HAND NUMBNESS, SHOOTING ELECTRICAL TYPE SENSATION DOWN HIS ARMS AND BILATERAL ARM WEAKNESS. HE STATES THIS STARTED AFTER HE JAMMED HIS HEAD INTO A VEHICLE DOOR WHEN HE WAS REACHING INTO HIS VEHICLE. HE REPORTS HE HAS PAIN ALL THE WAY INTO HIS ARMS AND INTO THE SECOND, THIRD, AND FOURTH DIGITS. THE SURGEON REPORTED LOOSENING OF BOTH THE CRANIAL AND CAUDAL COMPONENT. THERE WAS ALSO SUBSIDENCE REPORTED FOR THE CAUDAL COMPONENT. A REVISION SURGERY OCCURRED ON (B)(6), 2015.

    Patient problems: Failure of Implant

    MAUDE report 5178292 ↗

Other Prosthesis, Intervertebral Disc devices

All Prosthesis, Intervertebral Disc devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page