Arthrex® AR-5025TDC-26Recalls & reported problems
Arthrex, Inc. · COMPRESSION SCREW CANLTD DRILL BIT 26MM · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867034976), received between Oct 12, 2016 and Oct 12, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Bent” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Bent1
- Material Fragmentation1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 12, 2016Bent; Material Fragmentation
IT WAS REPORTED THAT WHILE DRILLING IN THE MEDIAL CONDYLE FOR A COMPRESSION SCREW FOR A KNEE SCOPE-OCD REPAIR, PIECES OF THE DRILL BROKE OFF. WHEN THE DRILL WAS REMOVED THE K-WIRE WAS LODGED IN THE CANNULATION. IT WAS BENT AND REMOVED ON THE BACK TABLE. IT WAS NOT REALIZED UNTIL THE CONCLUSION OF DRILLING THAT THE FRAGMENTS WERE MISSING. THE FRAGMENTS WERE LEFT IN THE BOTTOM OF THE SOCKET AND WERE CONFIRMED BY X-RAYS. IT WAS REPORTED THAT THE RESULT OF THE CASE WAS UNAFFECTED BY THE DRILL FRAGMENTS AND THE SURGEON WAS SATISFIED WITH THE COMPRESSION AND FIXATION OF THE CHONDRAL DEFECT.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 6022130 ↗
Other BIT, DRILL devices
- QUICKSET 2274-25-500Depuy Orthopaedics, Inc. · BIT, DRILL1,985 reports
- QUICKSET 2274-35-500Depuy Orthopaedics, Inc. · BIT, DRILL770 reports
- QUICKSET 2274-30-500Depuy Orthopaedics, Inc. · BIT, DRILL761 reports
- NA 03.037.022Synthes GmbH · BIT, DRILL339 reports
- NA 323.062Synthes GmbH · BIT, DRILL309 reports
- QUICKSET 2274-56-000Depuy (Ireland) · BIT, DRILL275 reports
- QUICKSET 2274-45-500Depuy Orthopaedics, Inc. · BIT, DRILL211 reports
- LCS 2366-83-000Depuy (Ireland) · BIT, DRILL207 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.