Arthrex® AR-9502-42ARCARecalls & reported problems
Arthrex, Inc. · Revers 42MM CA Adapter Assembly · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00888867230392), received between Aug 5, 2020 and Mar 13, 2025 — classified as 3 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Positioning Failure” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Positioning Failure3
- Adverse Event Without Identified Device or Use Problem1
- Fitting Problem1
Patient problems
- Insufficient Information3
- No Clinical Signs, Symptoms or Conditions3
- Pain1
- Unspecified Infection1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 13, 2025Positioning Failure; Positioning Failure
ON (B)(6)2025, A SALES REPRESENTATIVE REPORTED VIA PHONE THAT A PATIENT UNDERWENT REVISION SURGERY. THE PATIENT HAD IMPLANTS FROM ANOTHER MANUFACTURER AND THOSE IMPLANTS WERE ATTEMPTED TO BE PAIRED WITH AN AR-9502F-42CPC ARTHREX UNIVERS REVERS SUTURE CUP AND A 9 MM STEM. THE STEM AND CUP WERE WELL FIXED WHILE THE BASEPLATE AND GLENOID COMPONENTS FROM ANOTHER MANUFACTURER HAD BEEN LEVERED OUT. BECAUSE THE STEM WAS WELL FIXED THE SURGEON DECIDED TO CONVERT IT TO A CA HEAD TO GIVE THE PATIENT A MINIMAL AMOUNT OF MOVEMENT. THE POLY WAS REMOVED, AND CUP WAS CLEANED THEN A 42 INSERT WAS OPENED IN WHICH THE SURGEON COULD NOT GET THE CA INSERT TO A COUPLE WITH THE AR-9502F-42CPC ARTHREX UNIVERS REVERS SUTURE CUP. A NEW AR-9502F-42CPC ARTHREX UNIVERS REVERS SUTURE CUP WAS OPENED AND WAS ATTEMPTED TO BE INSERTED AGAIN WITH NO AVAIL. A NEW INSERT WAS OPENED, WHICH PHYSICALLY, IT LOOKED DIFFERENT, IT WAS SLIGHTLY BIGGER AND WOULD NOT ALLOW TO SEAT INTO THE CUP. FINALLY, A 93 CUP OF A 39 INSERT WAS ABLE TO WORK. THIS WAS DISCOVERED DURING A REVISION REVERS SURGERY ON (B)(6) 2025. ADDITIONAL INFORMATION REQUESTED ON 2/28/2025.
Patient problems: Insufficient Information
MAUDE report 21596584 ↗InjuryMar 6, 2025Positioning Failure; Positioning Failure
ON 02/14/2025, A SALES REPRESENTATIVE REPORTED VIA EMAIL THAT THE FOLLOWING ARTHREX PARTS (QTY. 2) OF AN AR-9502-42ARCA UNIVERS REVERS CA HUMERAL HEAD ADAPTER 42, AR-9502-39ARCA UNIVERS REVERS CA HUMERAL HEAD ADAPTER 39, AR-9556-22RCA UNIVERS REVERS CA HUMERAL HEAD 56/22, AR-9502F-42CPC ARTHREX UNIVERS REVERS SUTURE CUP, 42, AR-9502F-39CPC ARTHREX UNIVERS REVERS SUTURE CUP, 39 (NEUTRAL), AR-9501-10P ARTHREX UNIVERS REVERS HUMERAL STEM, SIZE 10 WERE UNSUCCESSFUL IN SEATING THE 42 ADAPTER INTO THE 42 CUP. A 39 ADAPTER AND A 39 CUP WERE ALSO ATTEMPTED BUT UNSUCCESSFUL IN PROPERLY SEATING. NOTHING BROKE INSIDE THE PATIENT. THE PROCEDURE WAS ABORTED. THIS WAS DISCOVERED DURING A REVISION REVERSE SHOULDER PROCEDURE ON (B)(6) 2025. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 21536165 ↗InjuryMar 6, 2025Positioning Failure; Positioning Failure
ON 02/14/2025, A SALES REPRESENTATIVE REPORTED VIA EMAIL THAT THE FOLLOWING ARTHREX PARTS (QTY. 2) OF AN AR-9502-42ARCA UNIVERS REVERS CA HUMERAL HEAD ADAPTER 42, AR-9502-39ARCA UNIVERS REVERS CA HUMERAL HEAD ADAPTER 39, AR-9556-22RCA UNIVERS REVERS CA HUMERAL HEAD 56/22, AR-9502F-42CPC ARTHREX UNIVERS REVERS SUTURE CUP, 42, AR-9502F-39CPC ARTHREX UNIVERS REVERS SUTURE CUP, 39 (NEUTRAL), AR-9501-10P ARTHREX UNIVERS REVERS HUMERAL STEM, SIZE 10 WERE UNSUCCESSFUL IN SEATING THE 42 ADAPTER INTO THE 42 CUP. A 39 ADAPTER AND A 39 CUP WERE ALSO ATTEMPTED BUT UNSUCCESSFUL IN PROPERLY SEATING. NOTHING BROKE INSIDE THE PATIENT. THE PROCEDURE WAS ABORTED. THIS WAS DISCOVERED DURING A REVISION REVERSE SHOULDER PROCEDURE ON (B)(6) 2025. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 21536150 ↗MalfunctionSep 18, 2024Fitting Problem; Fitting Problem
ON 09/9/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-9502-42ARCA UNIVERS REVERS CA HUMERAL HEAD ADAPTER POOPED OFF WHEN THE HUMERAL HEAD WAS PUT ON. THE HUMERAL HEAD WAS REMOVED FROM THE ADAPTER, AND THEN THE SURGEON ATTEMPTED TO INSERT IT AGAIN. IT APPEARED THAT THE ADAPTER WAS NOT SITTING WITH A REALLY GOOD SEAL ON THE SUTURE CUP. THE SURGEON ATTEMPTED MULTIPLE TIMES AGAIN WITHOUT SUCCESS. OVERALL, THE CASE WAS DELAYED FORTY-FIVE MINUTES WITH ADDITIONAL ANESTHESIA, WHILE WAITING FOR ANOTHER AR-9502-42ARCA UNIVERS REVERS CA HUMERAL HEAD ADAPTER TO BE BROUGHT INTO THE OPERATING ROOM. THE NEW ADAPTER WORKED PERFECTLY WITHOUT ANY ISSUES. THIS WAS DISCOVERED DURING A HEMI ARTHROPLASTY PROCEDURE ON (B)(6) 2024.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20248530 ↗InjuryAug 5, 2020Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT A UNIVERS REVERS TOTAL SHOULDER PROCEDURE (B)(6) 2019. THE PATIENT WAS EXPERIENCING POST OP PAIN AND AN INFECTION. THE ORIGINAL SURGEON PERFORMED A SECOND SURGERY AT THE SAME FACILITY (B)(6) 2020. DURING THE SECOND SURGERY THE FOLLOWING ORIGINAL ARTHREX PRODUCTS WERE EXPLANTED: AR-9501-06P, UNIVERS REVERS STEM, LOT 18.01910. AR-9502F-42CPC, UNIVERS REVERS SUTURE CUP, LOT 170095605. AR-9502-42ARCA, REVERS ADAPTER ASSEMBLY, LOT 241624. AR-9556-22RCA, REVERS CA HUMERAL HEAD, LOT 10165385. THE EXPLANTED DEVICES WILL BE RETURNED FOR EVALUATION. ADDITIONAL INFORMATION OBTAINED 7/22/20: THE GLENOID IMPLANTS FROM THE ORIGINAL PROCEDURE WERE LEFT IN THE PATIENT. THE ONLY DEVICES EXPLANTED WERE THE ABOVE LISTED IMPLANTS. THE SPECIFIC TYPE OF INFECTION OR ANY CULTURE RESULTS ARE NOT BEING PROVIDED TO THE SALES REP.
Patient problems: Pain; Unspecified Infection
MAUDE report 10366820 ↗
Other PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices
- DJO SURGICAL 509-02-032Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED364 reports
- DELTA XTEND 130790036Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED171 reports
- DELTA XTEND 130770018Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED159 reports
- TRIGEN 71118200Smith & Nephew, Inc. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED123 reports
- DJO SURGICAL 509-02-432Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED119 reports
- DELTA XTEND 130738206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED116 reports
- COMPREHENSIVE SHOULDER SYSTEM 113633Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED2 recalls4 reports
- DELTA XTEND 130742206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED99 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page