Arthrex® AR-7501Recalls & reported problems

Arthrex, Inc. · SutureTape 1.3mm WH/BL & WH/BLK · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867288812), received between Oct 25, 2023 and Oct 25, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 25, 2023Break; Break

    ON 9/29/2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS-06045007 THAT AN AR-13999HDN HD SCORPION NEEDLE WITH MEGALOADER, VE5, HAD AN ISSUE. THE SURGEON WAS COMPLETING AN AFLEX 301 PATCH OVER A ROTATOR CUFF, SIDE-SIDE REPAIR. THE SURGEON PLACED AND TIED 3 SUTURETAPES, STARTING ANTEROLATERAL AND MOVING POSTERIORLY. ON ATTEMPTING TO PLACE A FINAL SUTURE TAPE ON THE POSTEROLATERAL CORNER OF THE PATCH/CUFF TISSUE, THE DISTAL 8-9MM OF THE HD SCORPION NEEDLE BROKE OFF, CUTTING THE SUTURE. ON PULLING THE SCORPION OUT OF THE JOINT, THE BROKEN NEEDLE TIP FLEW OUT AND LANDED ON THE BACK SCRUB TABLE. THE SURGEON STATED AFTER THE CASE, ¿I FELT THE NEEDLE BEND AS I FIRED IT THROUGH THE PATCH.¿ THE CASE WAS COMPLETED USING ANOTHER AR-13999HDN HD SCORPION NEEDLE AND SEVERAL PACKS OF AR-7501 WITH A DELAY OF 4-5 MINUTES WHILE RETRIEVING AND OPENING A NEW SCORPION HD NEEDLE. THERE WAS NO ADDITIONAL ANESTHESIA NEEDED. THIS WAS DISCOVERED DURING ROTATOR CUFF REPAIR WITH A PATCH AUGMENTATION PROCEDURE ON (B)(6) 2023.

    Patient problems: Insufficient Information

    MAUDE report 18002086 ↗

Other SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE devices

All SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE devices →