FAST-FIX 72201494Recalls & reported problems
Smith & Nephew, Inc. · ULTRA FAST-FIX AB ASSEMBLY - CURVED · Class 2 · Implant
All models of FAST-FIX (18)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Smith & Nephew Ultra FAST-FIX suture device has 249 reports on file, with no deaths and 102 injuries. Many describe the anchor failing to deploy, breaking, or coming off the inserter during meniscus repair, and surgeons often switched to a backup device. Some note that parts were left in the patient. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 249
- Deaths reported
- 0
- Injuries reported
- 102
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 249 adverse event reports that list this exact device (DI 03596010597229), received between Oct 12, 2017 and Mar 23, 2026 — classified as 102 injuries, 147 malfunctions.
The most frequently reported specific device problem is “Failure to Fire” (95 reports).
40 other recalls cover devices cleared under the same FDA submission (K151105); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Fire95
- Firing Problem41
- Device Dislodged or Dislocated25
- Premature Activation23
- Break22
- Activation, Positioning or Separation Problem7
- Positioning Failure6
- Adverse Event Without Identified Device or Use Problem4
Patient problems
- No Clinical Signs, Symptoms or Conditions172
- No Known Impact Or Consequence To Patient50
- Device Embedded In Tissue or Plaque11
- Foreign Body In Patient7
- Insufficient Information5
- No Information5
- Injury2
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 25 most recent of 249 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 23, 2026Failure to Fire; Material Twisted/Bent
IT WAS REPORTED THAT, DURING AN ARTHROSCOPIC MENISCUS REPAIR, THE SECOND T OF AN ULTRA FAST-FIX FAILED TO DEPLOY. THE T WAS REMOVED WITH GRASPERS. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACK-UP. NO ADDITIONAL ANESTHESIA WAS REQUIRED. NO FURTHER COMPLICATIONS WERE REPORTED. THE PATIENT'S STATUS IS FINE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24663412 ↗MalfunctionJan 26, 2026Break
IT WAS REPORTED THAT, DURING A MENISCUS REPAIR, THE T1 IMPLANT OF ONE (1) ULTRA FAST-FIX CURVED BROKE IN HALF UPON TENSIONING THE REPAIR: THE T2 IMPLANT WAS LEFT SECURED IN THE PATIENT. THE PROCEDURE WAS RESUMED, WITH A NON-SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACKUP. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 24179772 ↗MalfunctionJan 26, 2026Premature Activation
IT WAS REPORTED THAT, DURING A MENISCUS REPAIR, THE T2 IMPLANT OF ONE (1) ULTRA FAST-FIX CURVED CAME OFF THE INSERTER WHEN TRYING TO ADVANCE IT TO THE DEPLOYMENT POSITION, THE T1 IMPLANT WAS LEFT SECURED INSIDE THE PATIENT. THE PROCEDURE WAS RESUMED, WITH A NON-SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACKUP. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 24179678 ↗MalfunctionJan 26, 2026Detachment of Device or Device Component
IT WAS REPORTED THAT, DURING A MENISCUS REPAIR, THE T1 IMPLANT OF ONE (1) ULTRA FAST-FIX CURVED WAS RIPPED OFF THE INSERTER AND WAS REMOVED FROM THE PATIENT WITH A SHAVER. THE PROCEDURE WAS RESUMED, WITH A NON-SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACKUP. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24179634 ↗MalfunctionDec 29, 2025Device Dislodged or Dislocated; Firing Problem; Device Dislodged or Dislocated; Firing Problem
IT WAS REPORTED THAT DURING A MENISCUS REPAIR, WHEN T1 WAS FIRED FROM ONE (1) ULTRA FAST-FIX, BOTH TS CAME OUT. T1 WAS DEPLOYED THROUGH THE MENISCUS. BOTH TS WERE REMOVED WITH TWEEZERS. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACK-UP. ADDITIONAL ANESTHESIA WAS NOT REQUIRED AS CONSEQUENCE OF THE SURGICAL PROLONGATION. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23919040 ↗MalfunctionDec 29, 2025Firing Problem; Firing Problem
IT WAS REPORTED THAT DURING A MENISCUS REPAIR, WHEN T1 WAS FIRED FROM ONE (1) ULTRA FAST FIX, BOTH TS CAME OUT. THE PROCEDURE WAS RESUMED, AFTER A NON SIGNIFICANT DELAY, USING AN EQUIVALENT S+N BACK UP. ADDITIONAL ANESTHESIA WAS NOT REQUIRED AS CONSEQUENCE OF THE SURGICAL PROLONGATION. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23905933 ↗MalfunctionOct 29, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT, DURING A MENISCUS SUTURE SURGERY, WHEN TIGHTENING THE SUTURE, THE T1 OF THE ULTRA FAST FIX WAS DISLODGED FROM THE MENISCUS. T2 IMPLANT WAS REMOVED. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY USING A SN BACK-UP. THE PATIENT WAS FINE. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23415742 ↗MalfunctionOct 29, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT, DURING A MENISCUS SUTURE SURGERY, WHEN TIGHTENING THE SUTURE, THE T1 OF THE ULTRA FAST FIX WAS DISLODGED FROM THE MENISCUS. THE PROCEDURE WAS RESUMED, USING AN EQUIVALENT SN BACK-UP. IT IS UNKNOWN IF THERE WAS A DELAY. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23415643 ↗MalfunctionOct 19, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A MENISCUS ARTHROSCOPIC REPAIR, THE UTRA FAST-FIX THREAD SEEMS TO HAVE EITHER BEEN TORN OR NOT ATTACHED FROM THE BEGINNING, BECAUSE THE THREAD AND T2 CAME OUT OF THE JOINT TOGETHER. THE T2 WAS REMOVED, AND THE T1 REMAINED SECURED IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITHOUT A SURGICAL DELAY USING A FAST-FIX 360 AS THE BACK-UP DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 23334029 ↗MalfunctionJun 5, 2025Break; Material Deformation; Material Split, Cut or Torn; Break; Material Deformation; Material Split, Cut or Torn
IT WAS REPORTED THAT DURING INSPECTION (1) ULTRA-FAST FIX HAD DETERIORATED, T1 HAD BEEN CUT FROM THE SUTURE. T2 WAS DEFORMED AND FRAGMENTED ON THE SUTURE. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22150006 ↗MalfunctionJan 13, 2025Premature Activation; Premature Activation
IT WAS REPORTED THAT DURING KNEE ARTHROSCOPY, SEVEN (7) ULTRA FAST-FIX DEVICES CONSECUTIVELY EXPERIENCED PREMATURE DEPLOYMENT OF THE TS. THREE (3) DEVICES FAILED INTERNAL TO THE PATIENT. OF THE THREE (3) FAT FIX THAT FAILED INSIDE THE PATIENT, FIVE T-IMPLANTS WERE LEFT SECURED IN THE PATIENT IN TOTAL. THREE T1 AND TWO T2. NO T-IMPLANTS WERE REMOVED. THE PROCEDURE WAS COMPLETED USING A S+N BACKUP DEVICE. THERE WAS A SURGICAL DELAY OF LESS THAN 30 MINUTES. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 21139074 ↗MalfunctionDec 8, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT, DURING A MENISCUS REPAIR, THE ULTRA FAST-FIX CURVED T2 DID NOT TRIGGER. SURGERY WAS COMPLETED WITH A BACK-UP DEVICE INSTEAD. THERE WAS A DELAY OF LESS THAN 30 MINUTES, AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20875375 ↗MalfunctionDec 7, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT, DURING AN ARTHROSCOPY, THE T2 OF THE ULTRA FAST-FIX DID NOT TRIGGER. SURGERY WAS COMPLETED WITH A SMITH AND NEPHEW BACK-UP DEVICE INSTEAD. THERE WAS A DELAY OF LESS THAN 30 MINUTES, AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20874167 ↗MalfunctionDec 5, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT DURING AN ARTHROSCOPY PROCEDURE, THE ULTRA FAST FIX T2 DID NOT TRIGGER. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A DELAY OF LESS THAN 30 MINUTES USING A SMITH AND NEPHEW BACK UP DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20859154 ↗MalfunctionNov 15, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A MENISCUS REPAIR, THE T1 IMPLANT OF THE ULTRA FAST FIX PULLED OUT AFTER DEPLOYING T2. BOTH T'S WERE REMOVED WITH TWEEZERS. THE PROCEDURE WAS COMPLETED WITH A SMITH AND NEPHEW BACK UP DEVICE. THERE WAS A DELAY LESS THAN 30 MINUTES AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20700561 ↗MalfunctionOct 14, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT, DURING A MENISCUS PROCEDURE, THE T2 OF TWO (2) UNITS OF THE ULTRA FAST-FIX CURVED WERE DISLODGED IN THE MENISCUS. NONE OF THE T-IMPLANTS WERE SECURED IN THE PATIENT, AND T1 WAS SUCCESSFULLY REMOVED WITH TWEEZERS. THERE WAS A BACK-UP DEVICE AVAILABLE, AND THERE WAS A DELAY OF LESS THAN 30 MINUTES. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20446580 ↗MalfunctionJul 15, 2024Break; Break
IT WAS REPORTED THAT DURING A MENISCUS REPAIR SURGERY, THE FAST FIX ONE SIDE OF THE T IMPLANT FOR THE SECOND DEVICE WAS INCOMPLETE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED USING A BACK-UP DEVICE. THERE WAS A SURGICAL DELAY LESS THAN 30 MINUTES AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19739894 ↗MalfunctionJul 1, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT DURING A MENISCUS REPAIR SURGERY, TWO ULTRA FAST-FIX FAILED IN THE SAME WAY. THE T2 WAS STUCK AND COULD NOT BE DEPLOYED, THE T1 WAS REMOVED DIRECTLY FROM THE PATIENT. THE PROCEDURE WAS COMPLETED USING A S+N BACK UP DEVICE. THERE WAS A DELAY OF LESS THAN 30 MINUTES. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19646163 ↗MalfunctionJun 26, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A LIGAMENT SURGERY, THE T1 AND T2 IMPLANTS OF THE ULTRA FAST FIX FELL OFF WHEN THE SUTURE KNOT WAS TIGHTENED. BOTH T IMPLANTS WERE REMOVED WITH TWEEZERS. THE PROCEDURE WAS COMPLETED WITH A STARSPORTMED COMPETITOR DEVICE. THERE WAS A DELAY OF LESS THAN 30 MINUTES AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19620457 ↗MalfunctionJun 17, 2024Break; Failure to Fire; Break; Failure to Fire
IT WAS REPORTED THAT DURING AN ARTHROSCOPY, THE ULTRA FAST-FIX BROKE, QUALITY ISSUES WERE REPORTED. THE PROCEDURE WAS COMPLETED USING A S+N BACK UP DEVICE. THERE WAS A DELAY GREATER THAN 30 MINUTES. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19548086 ↗MalfunctionJun 14, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT DURING A MENISCUS REPAIR, THE T1 IMPLANT OF TWO (2) ULTRA FAST-FIX DEVICES RECEDED DURING DEPLOYMENT, MULTIPLE ATTEMPTS BUT STILL FAILED. THE PROCEDURE WAS FINISHED WITH A SMITH AND NEPHEW BACK UP DEVICE. THERE WAS A SURGICAL DELAY GREATER THAN 30 MINUTES AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19538355 ↗MalfunctionJun 12, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT DURING A MENISCUS REPAIR, AFTER THE ULTRA FAST-FIX T1 WAS IMPLANTED, THE T2 IMPLANT COULD NOT BE DEPLOYED. THE PROCEDURE WAS FINISHED WITH A SMITH AND NEPHEW BACK UP DEVICE. THERE WAS A SURGICAL DELAY LESS THAN 30 MINUTES AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19520422 ↗MalfunctionJun 12, 2024Break; Break
IT WAS REPORTED THAT DURING A MENISCUS REPAIR, TWO(2) ULTRA FAST-FIX DEVICES PRESENTED A FAILURE, THE T IMPLANT OF BOTH DEVICES WAS FOUND TO BE INCOMPLETE. THE PROCEDURE WAS FINISHED WITH A SMITH AND NEPHEW BACK UP DEVICE. THERE WAS A SURGICAL DELAY LESS THAN 30 MINUTES AND NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19520360 ↗MalfunctionJun 3, 2024Failure to Fire; Failure to Fire
IT WAS REPORTED THAT, DURING ARTHROSCOPY, THE T2 OF A ULTRA FAST-FIX COULD NOT BE DEPLOYED. SURGERY WAS COMPLETED WITH A BACK-UP DEVICE INSTEAD. IT IS UNKNOWN IF THERE WAS ANY SURGICAL DELAY. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19455345 ↗MalfunctionMay 13, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A MENISCAL REPAIR SURGERY, A FAST FIX T2 FAILED TO IMPLANTED NORMALLY. SURGERY RESUMED WITH A BACK-UP DEVICE; HOWEVER IT IS UNKNOWN IF THERE WAS ANY DELAY. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19305137 ↗
FDA clearance and classification
Cleared through 510(k) K151105 on Jul 28, 2015 (decision: Substantially Equivalent). Submitted by Smith & Nephew, Inc. as “Smith and Nephew Suture Anchors - 5.0mm Absorbable Polymer Anchor, Smith and Nephew Suture Anchors - TAG Bioraptor Suture Anchor 7209317, 7209318, Smith and Nephew Suture Anchors - Bioraptor 2.3 PK Suture Anchor, Smith and Nephew Suture Anchors - Osteoraptor Suture Anchor, Smith and Nephew Suture Anchors - Twinfix Ultra HA Suture Anchor, Smith and Nephew Suture Anchors - OSTEORAPTOR Curved Suture Anchors, Smith and Nephew Suture Anchors - Ultra Fast-Fix Meniscal Repair System, Ultra Fa”. The FDA review took 95 days. FDA record ↗
The FDA regulates product code GAT (suture, nonabsorbable, synthetic, polyethylene) under 21 CFR 878.5000 as a Class II device. 21 CFR 878.5000 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K151105. One submission often covers many models, so check the product and lot details in each record.
- Z-0144-2021 · Sep 9, 2020 · Open, ClassifiedULTRA FAST-FIX AB ASSEMBLY - CURVED-Absorbable Suture anchors Product Number: 72201494
- Z-0137-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX 5.0MM AB SUTURE ANCHOR WITH TWO- Absorbable Suture anchors Product Number: 7210710
- Z-0163-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX ULTRA HA 5.5 W/2 UB BLUE & BLK- Absorbable Suture anchor Product Number: 72202626
- Z-0174-2021 · Sep 9, 2020 · Open, ClassifiedMICRORAPTOR REGENESORB SUTURE ANCHOR- Absorbable Suture anchor Product Number: 72204983
- Z-0138-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX 5.0MM AB SUTURE ANCHOR-Absorbable Suture anchors Product Number: 7210711
- Z-0147-2021 · Sep 9, 2020 · Open, ClassifiedRAPTORMITE 3.7MM AB W/ NEEDLES AND TWO-Absorbable Suture anchor Product Number: 72201805
- Z-0160-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX ULTRA PLLA HA 5.5MM W/ NEEDLES- Absorbable Suture anchor Product Number: 72202616
- Z-0157-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX ULTRA 6.5MM PLLA/HA 2 UBWHT/BL-Absorbable Suture anchor Product Number: 72202608
- Z-0142-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX AB 5.0 SUTR ANCHR W/2 38 DURAB-Absorbable Suture anchors Product Number: 72200785
- Z-0162-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX ULTRA HA 4.5 W/2 UB BLUE & BLK- Absorbable Suture anchor Product Number: 72202624
- Z-0136-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX 5.0MM AB SUTURE ANCHOR WITH TWO Absorbable Suture anchors Product Number: 7210309
- Z-0164-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX ULTRA HA 6.5 W/2 UB (BLUE & BLK)- Absorbable Suture anchor Product Number: 72202631
- Z-0170-2021 · Sep 9, 2020 · Open, ClassifiedHEALICOIL RG SA 5.5MM W/2 UB-BL CBR BL-- Absorbable Suture anchor Product Number: 72203706
- Z-0173-2021 · Sep 9, 2020 · Open, ClassifiedHEALICOIL RSB SA 5.5MM W/1 UT & 1 UB BL- Absorbable Suture anchor Product Number: 72203801
- Z-0140-2021 · Sep 9, 2020 · Open, ClassifiedTWINFIX 6.5MM AB PRELOADED SUTURE ANCHOR- Absorbable Suture anchors Product Number: 7210713
…and 25 more.
Common questions about the FAST-FIX 72201494
Has the FAST-FIX 72201494 been recalled?
No FDA recall record in our data names this exact device identifier (DI 03596010597229), based on the FDA recall file dated Nov 27, 2026. However, 40 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the FAST-FIX 72201494?
The FDA's MAUDE database lists 249 adverse event reports for this device, received between Oct 12, 2017 and Mar 23, 2026. In those reports, the most common specific device problems are “Failure to Fire” (95), “Firing Problem” (41) and “Device Dislodged or Dislocated” (25); the most common patient problems are “Device Embedded In Tissue or Plaque” (11), “Foreign Body In Patient” (7) and “Injury” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the FAST-FIX 72201494?
None of the reports are classified as deaths, 102 as injuries and 147 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the FAST-FIX 72201494 FDA approved?
It was cleared through 510(k) K151105 on Jul 28, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the FAST-FIX 72201494 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the FAST-FIX 72201494, and is it still sold?
The FDA's device database lists Smith & Nephew, Inc. as the company responsible for it (brand FAST-FIX, model 72201494). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE devices
- FAST-FIX 72202468Smith & Nephew, Inc. · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE1 death6,566 reports
- FAST-FIX 72201491Smith & Nephew, Inc. · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE862 reports
- FAST-FIX 72202469Smith & Nephew, Inc. · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE561 reports
- FAST-FIX 72205676Smith & Nephew, Inc. · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE428 reports
- Arthrex® AR-4501Arthrex, Inc. · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE400 reports
- FAST-FIX 72205324Smith & Nephew, Inc. · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE381 reports
- LUPINE ORTHOCORD 210712Medos International Sàrl · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE352 reports
- ETHIBOND EXCEL X557HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE187 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page