Arthrex® AR-3638H-1Recalls & reported problems

Arthrex, Inc. · KNOTLESS HIP FiberTak · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 00888867295575), received between May 24, 2021 and Dec 3, 2025 — classified as 12 malfunctions.

The most frequently reported specific device problem is “Positioning Failure” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 2 reportsSep 2024: 3 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 2 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure7
  • Failure to Advance2
  • Material Split, Cut or Torn2
  • Device Dislodged or Dislocated1
  • Difficult to Advance1
  • Material Rupture1

Patient problems

  • Insufficient Information7
  • No Clinical Signs, Symptoms or Conditions4
  • Failure of Implant1

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 3, 2025Material Split, Cut or Torn; Material Split, Cut or Torn

    ON 14 NOVEMBER 2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT 2 X AR-3638H-1, KNOTLESS HIP FIBERTAK WERE REPORTED TO HAVE CUT THE SHUTTLING SUTURE ONCE INSERTED. THIS OCCURRED ON (B)(6) 2025 DURING A HIP LABRAL REPAIR. THE CASE WAS COMPLETED SUCCESSFULLY USING A HIP LENGTH PUSHLOCK. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 23703825 ↗
  • MalfunctionDec 3, 2025Material Split, Cut or Torn; Material Split, Cut or Torn

    ON (B)(6) 2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT 2 X AR-3638H-1, KNOTLESS HIP FIBERTAK WERE REPORTED TO HAVE CUT THE SHUTTLING SUTURE ONCE INSERTED. THIS OCCURRED ON (B)(6) 2025 DURING A HIP LABRAL REPAIR. THE CASE WAS COMPLETED SUCCESSFULLY USING A HIP LENGTH PUSHLOCK. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 23703763 ↗
  • MalfunctionMay 19, 2025Positioning Failure; Device Dislodged or Dislocated; Positioning Failure; Device Dislodged or Dislocated

    ON 24 APRIL 2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT 2 X AR-3638H-1 KNOTLESS HIP FIBERTAK AND ONE AR-2923PS, SUTR ANCHPEEK P-LCK2.9X 12.5MM WERE REPORTED TO HAVE FAILED DURING USE. THIS OCCURRED ON (B)(6) 2025 DURING A RIGHT HIP ARTHROSCOPY & LABRAL REPAIR. IT WAS REPORTED SURGEON PERFORMING A LABRAL REPAIR OF RIGHT HIP. SURGEON USING KNOTLESS HIP FIBERTAK SUTURE ANCHORS. 2X ANCHORS DEPLOYED ALREADY INTO JOINT. STAFF OPENED A 3RD ANCHOR. UNFORTUNATELY, THE SUTURES HAD UNRAVELLED FROM THE INSERTER AND WERE UNABLE TO BE RE-POSITIONED ONTO THE INSERTER. A 4TH ANCHOR WAS THEN OPENED AND USED, AND UNFORTUNATELY PULLED STRAIGHT BACK OUT. ALL PIECES OF THE SUTURE ANCHOR REMOVED FROM THE JOINT. SURGEON THEN OPTED TO USE A HIP PUSHLOCK ANCHOR WITH 1.3MM SUTURE TAPE. UPON INSERTION, IT WAS NOTED THAT THE EYELET BROKE. LIKELY DUE TO SUBOPTIMAL TRAJECTORY ON INSERTION. THE ANCHOR WAS REMOVED WITH NO PIECES REMAINING IN JOINT. THE CASE WAS COMPLETED SUCCESSFULLY USING A STRYKER CINCLOCK. THERE WAS CASE INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22043881 ↗
  • MalfunctionApr 30, 2025Positioning Failure; Positioning Failure

    IT WAS REPORTED THAT DURING A ROTATOR CUFF SURGERY THE IMPLANT DID NOT GRIP. PER COMPLAINT REPORTER THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY. THE SURGERY WAS FINISHED SUCCESSFULLY WITH A NEW DEVICE WITH THE SAME PART NUMBER. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21937446 ↗
  • MalfunctionApr 25, 2025Positioning Failure; Positioning Failure

    ON 24 APRIL 2025, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT 2 X AR-3638H-1 KNOTLESS HIP FIBERTAK AND ONE AR-2923PS, SUTR ANCHPEEK P-LCK2.9X 12.5MM WERE REPORTED TO HAVE FAILED DURING USE. THIS OCCURRED ON (B)(6) 2025 IN (B)(6) DURING A RIGHT HIP ARTHROSCOPY & LABRAL REPAIR. IT WAS REPORTED SURGEON PERFORMING A LABRAL REPAIR OF RIGHT HIP. SURGEON USING KNOTLESS HIP FIBERTAK SUTURE ANCHORS. 2X ANCHORS DEPLOYED ALREADY INTO JOINT. STAFF OPENED A 3RD ANCHOR. UNFORTUNATELY, THE SUTURES HAD UNRAVELLED FROM THE INSERTER AND WERE UNABLE TO BE RE-POSITIONED ONTO THE INSERTER. A 4TH ANCHOR WAS THEN OPENED AND USED, AND UNFORTUNATELY PULLED STRAIGHT BACK OUT. ALL PIECES OF THE SUTURE ANCHOR REMOVED FROM THE JOINT. SURGEON THEN OPTED TO USE A HIP PUSHLOCK ANCHOR WITH 1.3MM SUTURE TAPE. UPON INSERTION, IT WAS NOTED THAT THE EYELET BROKE. LIKELY DUE TO SUBOPTIMAL TRAJECTORY ON INSERTION. THE ANCHOR WAS REMOVED WITH NO PIECES REMAINING IN JOINT. THE CASE WAS COMPLETED SUCCESSFULLY USING A STRYKER CINCLOCK. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 21910025 ↗
  • MalfunctionOct 1, 2024Positioning Failure; Positioning Failure

    ON 18 SEPTEMBER 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3638H-1 KNOTLESS HIP FIBERTAK FAILED TO ANCHOR PROPERLY. THIS OCCURRED ON 17 AUGUST 2024 IN (B)(6) DURING A HIP LABRAL REPAIR. THE CASE WAS COMPLETED SUCCESSFULLY USING FURTHER ANCHORS. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 20344159 ↗
  • MalfunctionSep 25, 2024Failure to Advance; Difficult to Advance; Failure to Advance; Difficult to Advance

    ON 18 SEPTEMBER 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3638H-1 KNOTLESS HIP FIBERTAK FAILED TO ANCHOR PROPERLY. THIS OCCURRED ON (B)(6) 2024 IN (B)(6)HOSPITAL DURING A HIP LABRAL REPAIR. THE CASE WAS COMPLETED SUCCESSFULLY USING FURTHER ANCHORS. THERE WAS CASE INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20302757 ↗
  • MalfunctionSep 25, 2024Failure to Advance; Failure to Advance

    ON 18 SEPTEMBER 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3638H-1 KNOTLESS HIP FIBERTAK FAILED TO ANCHOR PROPERLY. THIS OCCURRED ON (B)(6) 2024 IN ST VINCENT¿S PRIVATE HOSPITAL SYDNEY DURING A HIP LABRAL REPAIR. THE CASE WAS COMPLETED SUCCESSFULLY USING FURTHER ANCHORS. THERE WAS CASE INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20301600 ↗
  • MalfunctionSep 24, 2024Positioning Failure; Positioning Failure

    ON 18 SEPTEMBER 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3638H-1 KNOTLESS HIP FIBERTAK FAILED TO ANCHOR PROPERLY. THIS OCCURRED ON (B)(6) 2024 IN (B)(6) HOSPITAL DURING A HIP LABRAL REPAIR. THE CASE WAS COMPLETED SUCCESSFULLY USING FURTHER ANCHORS. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 20292685 ↗
  • MalfunctionAug 7, 2024Positioning Failure; Positioning Failure

    ON 25 JULY 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3638H-1 KNOTLESS HIP FIBERTAK WAS REPORTED TO HAVE FAILED DURING USE. THIS OCCURRED ON (B)(6) 2024 IN (B)(6) DURING A HIP ARTHROSCOPY & STABILIZATION. THE IMPLANT FAILED TO ANCHOR. THE CASE WAS COMPLETED SUCCESSFULLY USING ANOTHER IMPLANT. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 19929704 ↗
  • MalfunctionAug 7, 2024Positioning Failure; Positioning Failure

    ON (B)(6) 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-3638H-1 KNOTLESS HIP FIBERTAK WAS REPORTED TO HAVE FAILED DURING USE. THIS OCCURRED ON (B)(6) 2024 IN (B)(6) HOSPITAL DURING A HIP ARTHROSCOPY & STABILIZATION. THE IMPLANT FAILED TO ANCHOR. THE CASE WAS COMPLETED SUCCESSFULLY USING ANOTHER IMPLANT. THERE WAS CASE INVOLVEMENT.

    Patient problems: Insufficient Information

    MAUDE report 19929425 ↗
  • MalfunctionMay 24, 2021Material Rupture

    IT WAS REPORTED THAT DURING A HIP ARTHROSCOPY THE KNOTLESS ANCHOR WAS PLACED AND WHILE TIGHTENING THE SUTURE IT RUPTURED AND THE IMPLANT REMAINED IN THE PATIENT. THE SURGEON REPORTED THAT THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY REPORTED. THE SURGERY WAS FINISHED SUCCESSFULLY WITH A NEW DEVICE WITH THE SAME PART NUMBER. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 11872311 ↗

Other Fastener, fixation, nondegradable, soft tissue devices

All Fastener, fixation, nondegradable, soft tissue devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page