Arthrex® AR-2600FSB-1Recalls & reported problems

Arthrex, Inc. · FBRTK SPDBRG IMP SYS W/ BC SWVLK · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888867429857), received between Sep 10, 2024 and Oct 28, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Device Dislodged or Dislocated1
  • Material Frayed1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Foreign Body In Patient1
  • Insufficient Information1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 28, 2025Material Frayed; Material Frayed

    ON 10/10/2025, A SALES REPRESENTATIVE REPORTED VIA PHONE THAT AN AR-2600FSB-1 FIBERTAK® SPEEDBRIDGE¿ IMPLANT SYSTEMS SUTURES BEGAN TO FRAY. THIS OCCURRED DURING A ROTATOR CUFF REPAIR ON (B)(6) 2025 WHEN THE SUTURE ON THE FIBERTAK ANCHOR WAS PASSED THROUGH THE ROTATOR CUFF. THE SURGEON BEGAN TO TENSION AND WHEN THE TENSION WAS PLACED ON THE SUTURES, THEY BEGAN TO FRAY. THE DEVICE WAS STILL USED IN THIS PROCEDURE, AND THE ANCHOR WAS SECURED. THERE WAS NO MAJOR DELAY DURING THIS EVENT, AND NO HARM TO THE PATIENT. ADDITIONAL INFORMATION WAS PROVIDED ON 10/10/2025 WHERE IT WAS REPORTED THAT AN AR-3650DS WAS USED TO PREPARE THE BONE SOCKET FOR INSERTION OF THE IMPLANT. THE SURGEON USED THE DRILL GUIDE TO GET HIS LOCATION ON THE ARTICULAR MARGIN AND DRILLED WITH THE 2.6 DRILL BIT. THE PATIENT HAD GOOD BONE QUALITY AND ALL THREE 2.6 FIBERTAK ANCHORS WERE INSERTED CORRECTLY AND SET WELL AGAINST THE CORTICAL BONE. IT APPEARED THAT SUTURE FRAGMENTS ENTERED THE PATIENT. HOWEVER, THE SURGEON USED A SHAVER AND GRASPER TO RETRIEVE, AND IT APPEARS THAT THE FRAYED SUTURES WERE REMOVED.

    Patient problems: Foreign Body In Patient

    MAUDE report 23404111 ↗
  • MalfunctionAug 15, 2025Break; Break

    ADDITIONAL INFORMATION WAS RECEIVED ON 08/14/2025: SPECIFICALLY, THE 4.75 MM KNOTLESS BIOCOMPOSITE SWIVELOCK SP ANCHOR FROM THE AR-2600FSB-1 FIBERTAK SPEEDBRIDGE IMPLANT SYSTEM BROKE DURING THE PROCEDURE. THE CASE WAS COMPLETED USING ADDITIONAL READILY AVAILABLE IMPLANTS, RESULTING IN NO DELAY IN CASE PROGRESSION OR COMPLETION. THERE WAS NO REPORT OF ADDITIONAL ANESTHESIA ADMINISTERED. THE PART NUMBER OF THE IMPLANT USED TO COMPLETE THE CASE IS UNKNOWN.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 22815941 ↗
  • MalfunctionSep 10, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    ON 08/20/2024, A SALES REPRESENTATIVE REPORTED VIA PHONE THAT AN AR-2600FSB-1 FIBERTAK SPEEDBRIDGE IMPLANT SYSTEM, WHILE USING THE AR-3650DS DISPOSABLES KIT FOR 2.6 FIBERTAK, HAD AN ISSUE WITH TWO OUT OF THE THREE 2.6 FIBERTAK RC SELF-PUNCHING SOFT ANCHORS RIPPING AND PULLING OUT AND NEVER FULLY SETTING UPON IMPLANTING. THE CASE WAS COMPLETED USING A 4.75 SWIVELOCK. THERE WAS UNDER 15 MINUTES OF DELAY IN REMOVING THE TWO SUTURE ANCHORS THAT HAD RIPPED. THIS WAS DISCOVERED DURING A ROTATOR CUFF REPAIR PROCEDURE ON (B)(6) 2024, WITH NO REPORTED PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20180566 ↗

Other Fastener, Fixation, Nondegradable, Soft Tissue devices

All Fastener, Fixation, Nondegradable, Soft Tissue devices →