This is a DJO Surgical reverse shoulder replacement humeral stem used in shoulder arthroplasty. The 38 reports mostly describe the stem loosening within the bone, infection around the implant, and instability of the joint, with several patients needing revision surgery to remove or replace it; a few also mention a fracture. No deaths were reported, and all 38 reports describe injuries. There are no recalls naming this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
38
Deaths reported
0
Injuries reported
38
Recalls naming it
0

Summary

The FDA's MAUDE database contains 38 adverse event reports that list this exact device (DI 00888912168366), received between May 11, 2017 and May 4, 2026 — classified as 38 injuries.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (5 reports).

3 other recalls cover devices cleared under the same FDA submission (K141990); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 2 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 2 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem15
  • Appropriate Device Problem Term/Code Not Available9
  • Loose or Intermittent Connection5
  • Loosening of Implant Not Related to Bone-Ingrowth5
  • Unstable4
  • Device Dislodged or Dislocated2
  • Fracture2
  • Improper or Incorrect Procedure or Method1

Patient problems

  • Joint Laxity11
  • No Code Available8
  • Unspecified Infection6
  • Insufficient Information4
  • Failure of Implant3
  • Bacterial Infection1
  • Bone Fracture(s)1
  • Fracture, Arm1

Recent adverse event reports

The 25 most recent of 38 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 4, 2026Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY DUE REVERSE SHOULDER THAT WAS DONE YEARS AGO WAS INFECTED SO DOTOR REMOVED ALL IMPLANTS AND PUT IN AN ANTIBIOTIC SPACER.

    Patient problems: Unspecified Infection

    MAUDE report 25075538 ↗
  • InjuryApr 14, 2026Adverse Event Without Identified Device or Use Problem

    IMPLANT LOOSENING / POTENTIAL INFECTION.

    Patient problems: Joint Laxity; Unspecified Infection

    MAUDE report 24879885 ↗
  • InjuryDec 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    INFECTION IN HUMOROUS, LOOSE STEM.

    Patient problems: Septic loosening; Unspecified Infection

    MAUDE report 23763838 ↗
  • InjuryJul 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 22503274 ↗
  • InjuryApr 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 21905975 ↗
  • InjuryApr 2, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 21759178 ↗
  • InjuryNov 13, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO HUMERAL FRACTURE.

    Patient problems: Bone Fracture(s); Limb Fracture

    MAUDE report 20679406 ↗
  • InjurySep 5, 2024Unstable; Adverse Event Without Identified Device or Use Problem; Unstable; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO INSTABILITY.

    Patient problems: Joint Laxity

    MAUDE report 20153746 ↗
  • InjuryJun 8, 2024Unstable; Adverse Event Without Identified Device or Use Problem; Unstable; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO INSTABILITY.

    Patient problems: Joint Laxity

    MAUDE report 19494875 ↗
  • InjuryJun 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 19455653 ↗
  • InjuryOct 28, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - PATIENT WAS GETTING SOME DRAINAGE FROM THE INCISION FROM THE ORG SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 18026731 ↗
  • InjuryJul 20, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 17357305 ↗
  • InjuryJun 5, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO STEM ROTATED.

    Patient problems: Joint Laxity

    MAUDE report 17066637 ↗
  • InjuryNov 9, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - STEM BECAME LOOSE.

    Patient problems: Joint Laxity

    MAUDE report 15762737 ↗
  • InjuryAug 10, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY - BAD PATIENT BONE RESULTED IN CEMENTED STEM LOOSENING. USED A REVISION 10X175 REVISION STEM CEMENTED STEM TO REPLACE.

    Patient problems: Insufficient Information

    MAUDE report 15202829 ↗
  • InjuryApr 12, 2022Loosening of Implant Not Related to Bone-Ingrowth

    REVISION SURGERY - PATIENT HAS HAD A HISTORY OF VARIOUS INFECTION RESULTING IN MULTIPLE IRRIGATION & DRAINAGE WITH LINER CHANGES. SURGEON DISCOVERED PRIMARY STEM WAS LOOSE AND OPTED TO REMOVE AND REPLACE, IN ADDITION TO REPLACING HEAD AND LINER.

    Patient problems: Bacterial Infection

    MAUDE report 14085985 ↗
  • InjuryDec 21, 2021Fracture; Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY - DUE TO PERIPROSTHETIC FRACTURE.

    Patient problems: Insufficient Information

    MAUDE report 13052667 ↗
  • InjuryDec 16, 2021Loose or Intermittent Connection

    REVISION SURGERY - DUE TO LOOSE HUMERAL STEM.

    Patient problems: Insufficient Information

    MAUDE report 13018325 ↗
  • InjuryNov 29, 2021Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY - DUE TO STEM LOOSENING.

    Patient problems: Joint Laxity

    MAUDE report 12882828 ↗
  • InjurySep 9, 2021Appropriate Device Problem Term/Code Not Available; Loosening of Implant Not Related to Bone-Ingrowth

    REVISION SURGERY - STEM HEAD LOOSENED, NEEDED TO CEMENT IN NEW STEM.

    Patient problems: Insufficient Information

    MAUDE report 12448924 ↗
  • InjuryMay 12, 2021Packaging Problem

    PRIMARY SURGERY - DURING INSPECTION OF IMPLANT BEFORE OPENING ONTO THE STERILE FIELD A HAIR WAS DISCOVERED INSIDE THE PACKAGING OF THE IMPLANT. THE HAIR WAS IN THE INNER MOST LAYER (IMPLANT LAYER) OF THE PACKAGING. SURGEON WAS ABLE TO GRAB ANOTHER IMPLANT OF THE SHELF SO THERE WAS NO DISRUPTION IN THE SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11812407 ↗
  • InjuryOct 6, 2020Loosening of Implant Not Related to Bone-Ingrowth

    REVISION SURGERY - LOOSE SHOULDER DUE TO COMPONENTS.

    Patient problems: No Code Available

    MAUDE report 10634778 ↗
  • InjurySep 23, 2020Loose or Intermittent Connection

    REVISION SURGERY - HUMERUS FRACTURE CAUSED LOOSE STEM.

    Patient problems: Fracture, Arm

    MAUDE report 10574473 ↗
  • InjuryAug 28, 2020Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    REVISION SURGERY - LOOSE STEM.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10466883 ↗
  • InjuryJun 23, 2020Appropriate Device Problem Term/Code Not Available

    SECOND REVISION SURGERY - TOOK OUT THE OLD STEM THAT SURGEON MADE INTO A SPACER.

    Patient problems: No Code Available

    MAUDE report 10185023 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K141990. One submission often covers many models, so check the product and lot details in each record.

  • Z-1241-2018 · Jan 30, 2018 · Terminated
    AltiVate Reverse INSTRUMENTATION, HUMERAL SOCKET SHELL TRIAL, STANDARD, REF 804-06-152, Qty: 01, Encore Medical, LP Orthopedic surgical instrument. Product Usage: The humeral soc
  • Z-0626-2016 · Dec 8, 2015 · Terminated
    AltiVate Reverse Humeral Broach, Size 10 Catalog number 804-06-040, Size 14 Catalog number 804-06-044, and Size 16 Catalog number 804-06-046. Orthopedic surgical instrument for us
  • Z-0131-2016 · Sep 15, 2015 · Terminated
    AltiVate Humeral Socket Shell Trial, Part Number 804-06-052 The glenoid baseplate is intended for cementless application with addition of screws for fixation. The humeral stem is

Other Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented devices

All Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page