NexGen® 5881-26Recalls & reported problems

Zimmer, Inc. · Class 1

All models of NexGen (198)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 00889024199958), received between Jun 21, 2022 and Mar 16, 2026 — classified as 1 injury, 13 malfunctions.

The most frequently reported specific device problem is “Fracture” (14 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 2 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture14

Patient problems

  • No Clinical Signs, Symptoms or Conditions12
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Foreign Body In Patient1

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 16, 2026Fracture

    IT WAS REPORTED THAT A SCREWDRIVER FRACTURED WHILE TIGHTENING. THERE IS NO ADDITIONAL INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24606163 ↗
  • MalfunctionFeb 25, 2026Fracture

    IT WAS REPORTED DURING KNEE ARTHROPLASTY THAT THE HEX SCREW DRIVER HEAD FRACTURED WHILE TORQUING THE BOLT. NO ADVERSE EVENTS WERE REPORTED AS A RESULT OF THIS MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24445298 ↗
  • MalfunctionJan 6, 2026Fracture

    NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23981022 ↗
  • MalfunctionFeb 18, 2025Fracture; Fracture

    IT WAS REPORTED THAT THE TIP OF A SCREWDRIVER FRACTURED DURING SURGERY. THE FRACTURED PIECE WAS RECOVERED BY THE SURGEON. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE INFORMATION IS AVAILABLE AT THIS TIME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21399653 ↗
  • MalfunctionAug 7, 2024Fracture; Fracture

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Foreign Body In Patient

    MAUDE report 19927755 ↗
  • MalfunctionMar 6, 2024Fracture; Fracture

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18848773 ↗
  • MalfunctionFeb 27, 2024Fracture; Fracture

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18789808 ↗
  • MalfunctionDec 18, 2023Fracture; Fracture

    NO ADDITIONAL INFORMATION TO REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18348277 ↗
  • MalfunctionDec 5, 2023Fracture; Fracture

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18266291 ↗
  • MalfunctionOct 31, 2023Fracture; Fracture

    IT WAS REPORTED THE BROKEN SCREW DRIVER WAS FOUND IN THE LOANER KIT BY THE WAREHOUSE TEAM DURING CHECK IN, AFTER THE PRODUCRT WAS RECEIVED. THE CUSTOMER'S STERILIZATION SERVICE CONFIRMED BY TELEPHONE THE LOANER KIT WAS USED FOR A SURGERY, THAT THE INSTRUMENT WAS RETURNED BACK TO ZIMMER BIOMET IN THE KIT, BUT NO IMPACT ON PATIENT OR NO INCIDENT DURING THE SURGERY WAS REPORTED TO THE SERVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18038388 ↗
  • MalfunctionOct 31, 2023Fracture; Fracture

    IT WAS REPORTED THE BROKEN SCREW DRIVER WAS FOUND IN THE LOANER KIT BY THE WAREHOUSE TEAM DURING CHECK IN, AFTER THE PRODUCT WAS RECEIVED. THE CUSTOMER'S STERILIZATION SERVICE CONFIRMED BY TELEPHONE THE LOANER KIT WAS USED FOR A SURGERY, THAT THE INSTRUMENT WAS RETURNED BACK TO ZIMMER BIOMET IN THE KIT, BUT NO IMPACT ON PATIENT OR NO INCIDENT DURING THE SURGERY WAS REPORTED TO THE SERVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18038385 ↗
  • MalfunctionAug 29, 2023Fracture; Fracture

    IT WAS REPORTED THAT DURING A KNEE SURGERY, THE SURGEON WAS USING THE SCREWDRIVER WITH ITS TIP TO UNSCREW THE HINGE SCREW FROM THE PROSTHESIS IN A COUNTER-CLOCKWISE DIRECTION. AFTER THREE-FOURTHS OF A TURN, THE SCREWDRIVER JAMMED AND BROKE OFF INTO THE HINGE SCREW. IT WAS THEN NOT POSSIBLE TO REMOVE THE PROSTHESIS WITHOUT REMOVING THE HINGE. THIS RESULTED IN THE USE OF A LARGE NUMBER OF COMPLIMENTARY BOXES LEADING TO A RISK OF LACK OF MATERIAL FOR THE OTHER PATIENTS FOR THE DAY. IT ALSO INCREASED OPERATING TIME BY 2 HOURS. A DRILL BIT WAS USED TO REMOVE THE HINGE. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17640953 ↗
  • InjuryAug 29, 2022Fracture; Fracture

    IT WAS REPORTED THAT DURING A REVISION KNEE PROCEDURE, THE HEX DRIVER FRACTURED WHILE ATTEMPTING TO DECOUPLE THE KNEE PROSTHESIS. THE PROCEDURE WAS UNABLE TO BE COMPLETED AT THAT TIME. DUE DILIGENCE IS COMPLETE AS MULTIPLE ATTEMPTS WERE MADE; HOWEVER, NO FURTHER INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 15314666 ↗
  • MalfunctionJun 21, 2022Fracture; Fracture

    IT WAS REPORTED THAT THE TORQUE WENCH TIP BROKE OFF WHEN TRYING TO LOOSEN THE PEG SO THE SURGEON HAD TO USE A BURR TO CUT OFF THE HINGE POST TO REMOVE THE WHOLE FEMUR. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14754731 ↗

Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices

All ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices →