SILC 1116.0155Recalls & reported problems
Globus Medical, Inc. · SILC 5.5mm Inline Clamp · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889095029208), received between Feb 17, 2021 and Feb 17, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Separation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Material Separation1
- Positioning Failure1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 17, 2021Positioning Failure; Material Separation
IT WAS REPORTED THAT A REVISION SURGERY WAS DONE DUE TO CLAMPS THAT PULLED OFF THE ROD POST-OPERATIVELY. DURING THE REVISION THE REPLACEMENT CLAMPS WOULD NOT STAY ON THE ROD.
Patient problems: Insufficient Information
MAUDE report 11340490 ↗
FDA clearance and classification
Cleared through 510(k) K133482 on May 21, 2014 (decision: Substantially Equivalent). Submitted by Globus Medical, Inc. as “Silc Fixation System”. The FDA review took 189 days. FDA record ↗
The FDA regulates product code OWI (bone fixation cerclage, sublaminar) under 21 CFR 888.3010 as a Class II device. 21 CFR 888.3010 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: Acts as a bone anchor for temporary stabilization, or used in conjunction with other medical implants of similar metals when wiring is needed, during development of a spinal fusion.
Common questions about the SILC 1116.0155
Has the SILC 1116.0155 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00889095029208), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the SILC 1116.0155?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 17, 2021. That report lists device problems “Material Separation” (1) and “Positioning Failure” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SILC 1116.0155?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SILC 1116.0155 FDA approved?
It was cleared through 510(k) K133482 on May 21, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the SILC 1116.0155, and is it still sold?
The FDA's device database lists Globus Medical, Inc. as the company responsible for it (brand SILC, model 1116.0155). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Bone fixation cerclage, sublaminar devices
- TRANSLACE™ Spinal Tethering System 8219500Medtronic Sofamor Danek, Inc. · Bone fixation cerclage, sublaminar11 reports
- VersaTie 86101245Nuvasive, Inc. · Bone fixation cerclage, sublaminar4 reports
- VersaTie 8510260Nuvasive, Inc. · Bone fixation cerclage, sublaminar3 reports
- LIGAPASS B08110005Medicrea International · Bone Fixation Cerclage, Sublaminar3 reports
- KARMA 75035-175Spinal Elements, Inc. · Bone Fixation Cerclage, Sublaminar3 reports
- JAZZ LOCKImplanet · Bone Fixation Cerclage, Sublaminar3 reports
- VersaTie 8450001Nuvasive, Inc. · Bone fixation cerclage, sublaminar2 reports
- TRANSLACE™ Spinal Tethering System 8205300Medtronic Sofamor Danek, Inc. · Bone fixation cerclage, sublaminar2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page