ANTHEM 2187.4120Recalls & reported problems

Globus Medical, Inc. · ANTHEM Lateral Proximal Tibia Plate XR, Right, 20 Hole, 322mm, SS · Class 2

All models of ANTHEM (27)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889095614107), received between Mar 9, 2026 and Mar 9, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • Limb Fracture1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 9, 2026Fracture

    IT WAS REPORTED THAT THIS PLATE WAS PUT INTO A PATIENT WITH A PROXIMAL TIBIA FRACTURE IN MID (B)(6) 2025. THE PATIENT ATTEMPTED TO PUT WEIGHT ON HIS RIGHT LEG TOO SOON CAUSING ANOTHER FRACTURE IN HIS RIGHT TIBIA. HE WAS BROUGHT BACK FOR ADDITIONAL SURGERY. THE INITIAL PLAN WAS TO PUT ANOTHER PLATE MEDIALLY. HOWEVER, ONCE THE SURGEON TOOK X-RAYS IN THE OPERATING ROOM, HE NOTICED THAT THE PROXIMAL TIBIA PLATE WAS BROKEN. THE PROXIMAL TIBIA PLATE WAS REMOVED DUE TO THIS. THE SURGEON STATED THAT HE DOES NOT BELIEVE THE PLATE WAS NECESSARILY THE PROBLEM, HE THINKS THE CAUSE WAS THE PATIENT PUTTING TOO MUCH PRESSURE ON THE IMPLANT TOO EARLY ON. THE SURGEON ALSO STATED THAT THIS PLATE WAS NOT SUFFICIENT FOR THE PATIENT DUE TO HIS SIZE AND THAT COULD HAVE BEEN ANOTHER CAUSE.

    Patient problems: Limb Fracture

    MAUDE report 24545144 ↗

Other Plate, fixation, bone devices