Smith & Nephew, Inc. · 5.5 MM INCISOR STRAIGHT BLADES, POWER/EP-1, MOCHA, PACKAGED 6 PER BOX, STERILE · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 03596010251428), received between Feb 21, 2018 and Apr 29, 2025 — classified as 3 injuries, 5 malfunctions.

The most frequently reported specific device problem is “Flaked” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Flaked2
  • Material Fragmentation2
  • Adverse Event Without Identified Device or Use Problem1
  • Delivered as Unsterile Product1
  • Device Operates Differently Than Expected1
  • Metal Shedding Debris1
  • Packaging Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Known Impact Or Consequence To Patient3
  • Foreign Body In Patient1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 29, 2025Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem

    IT WAS REPORTED THAT, DURING AN ARTHROSCOPIC PROCEDURE, THE PACKAGING OF THE INCISOR BLADE WAS BROKEN, AFFECTING THE STERILITY OF THE BLADE. SURGERY WAS COMPLETED WITH A BACK-UP DEVICE INSTEAD. THERE WAS NO SURGICAL DELAY, AND NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21930658 ↗
  • InjuryAug 30, 2024Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT DURING AN ARTHROSCOPY, WHEN OPERATING THE SHAVER, METAL PARTICLES FELL FROM THE INCISOR BLADE AND REMAINED IN THE JOINT, THERE WAS NO CONTACT WITH BONE, LENS OR ANYTHING THAT WOULD ALLOW THE PARTICLES TO SPREAD, THE BLADE WAS ONLY IN CONTACT WITH SOFT TISSUE. THE MAJORITY OF THE PARTICLES WERE REMOVED USING ANOTHER BACKUP BLADE AND BY WASHING THE JOINT. THE PROCEDURE WAS COMPLETED WITHOUT SURGICAL DELAY USING A SMITH AND NEPHEW BACK UP DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20107257 ↗
  • MalfunctionMay 2, 2023Flaked; Flaked

    IT WAS REPORTED THAT DURING A SHOULDER ARTHROSCOPY METAL FILINGS WERE SEEN WHEN USING THE INCISOR 5.5MM EP-1 DSPL BLADE. NO UNDUE FORCE WAS APPLIED ON THE SHAVER BLADE. A SECOND BLADE WAS OPENED AND USED TO REMOVE METAL DEBRIS. THE PROCEDURE WAS COMPLETED WITH A NON-SIGNIFICANT SURGICAL DELAY USING A BACK-UP DEVICE. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16855828 ↗
  • InjuryDec 16, 2022Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, METAL PARTICLES WERE PRODUCED WHEN TWO(2) INCISOR BLADES WERE USED. THE PROCEDURE WAS COMPLETED USING A BACK-UP DEVICE AND IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY DUE TO THE REPORTED EVENTS. NO FURTHER COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15995797 ↗
  • InjuryJan 20, 2021Flaked; Flaked

    IT WAS REPORTED THAT DURING A KNEE ARTHROSCOPY PROCEDURE, THE SHAVER PRODUCED AN EXTENSIVE AMOUNT OF SMALL METAL SHAVINGS INTO THE PATIENT. PROCEDURE WAS COMPLETED WITH THE SAME INCISOR 5.5MM BLADE. NO DELAY AND NO PATIENT COMPLICATIONS WERE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. MI IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11200773 ↗
  • MalfunctionApr 6, 2018Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING THE PROCEDURE, WHEN IT WAS USING THE 5,5 MM BLADE, SOME SILVER PARTICLES WERE OBSERVED IN THE TISSUE, THE DOCTOR REALIZED THAT THEY WERE FROM THE BLADE WHEN IT WAS USED WITH THE SHAVER HANDPIECE, THE PARTICLES WERE REMOVED FROM THE TISSUE BY IRRIGATION - SUCTION. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7405316 ↗
  • MalfunctionMar 14, 2018Device Operates Differently Than Expected

    IT WAS REPORTED THAT WHILE THE JOINT WAS BEING CLEANED IT WAS NOTICED THAT THE BLADE WAS RELEASING METAL PARTICLES, AND THESE SPREAD THROUGHOUT THE JOINT. THE PROCEDURE WAS COMPLETED WITH THE SAME DEVICE. NO SIGNIFICANT DELAY OR PATIENT INJURY REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7339775 ↗
  • MalfunctionFeb 21, 2018Metal Shedding Debris

    IT WAS REPORTED THAT DURING THE PROCEDURE, WHEN IT WAS USING THE 5,5 MM BLADE, SOME SILVER PARTICLES WERE OBSERVED IN THE TISSUE, THE DOCTOR REALIZED THAT THEY ARE FROM THE BLADE WHEN IT WAS USED WITH THE SHAVER HANDPIECE, THE PARTICLES WERE REMOVED FROM THE TISSUE BY IRRIGATION - SUCTION. NO PATIENT INJURY REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7287437 ↗

FDA clearance and classification

The FDA regulates product code HAB (saw, powered, and accessories) under 21 CFR 878.4820 as a Class I device. 21 CFR 878.4820 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the NA 7205314

Has the NA 7205314 been recalled?

No FDA recall record in our data names this exact device identifier (DI 03596010251428), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the NA 7205314?

The FDA's MAUDE database lists 8 adverse event reports for this device, received between Feb 21, 2018 and Apr 29, 2025. In those reports, the most common specific device problems are “Flaked” (2), “Material Fragmentation” (2) and “Delivered as Unsterile Product” (1); the most common patient problem is “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the NA 7205314?

None of the reports are classified as deaths, 3 as injuries and 5 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the NA 7205314 FDA approved?

Devices of this type (product code HAB) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Smith & Nephew, Inc.

Who makes the NA 7205314, and is it still sold?

The FDA's device database lists Smith & Nephew, Inc. as the company responsible for it (brand NA, model 7205314). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.