Mixing System Adapted to High Viscosity Injection System T060420Recalls & reported problems

Teknimed · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03760177043138), received between May 19, 2026 and May 19, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 19, 2026Detachment of Device or Device Component

    AT THE START OF THE MIXING PROCESS, THE BLADE DETACHED FROM THE MIXER LID. AFTER ATTEMPTING TO REPOSITION IT, IT DID NOT ROTATE PROPERLY AND PRODUCED A GRINDING NOISE. AS A RESULT, THE CEMENT WAS NOT MIXED CORRECTLY AND THE REACTION PROCESS WAS COMPROMISED. ALTHOUGH THE PRE-DEFINED STORAGE CONDITIONS, PREPARATION STEPS, AND TIMING WERE FOLLOWED, THE CEMENT BEGAN TO HARDEN VERY RAPIDLY APPROXIMATELY 3 MINUTES AFTER MIXING THE LIQUID AND POWDER. NO PHYSICAL INJURY OCCURRED, HOWEVER, THE PROCEDURE COULD NOT BE COMPLETED. THE CEMENT COULD NO LONGER BE INJECTED. A SMALL AMOUNT HAD ALREADY BEEN DELIVERED INTO THE TRAJECTORY, BUT THE INJECTORS BECAME BLOCKED AND CLOGGED WITHIN MINUTES. NO ADDITIONAL CEMENT OR INJECTORS COULD BE INTRODUCED, LEADING THE SURGEON TO END THE PROCEDURE, AS THE TREATMENT COULD NOT BE PROPERLY COMPLETED. AT THIS TIME, NO INFORMATION WERE OBTAINED REGARDING ADDITIONAL PROCEDURES FOR THE PATIENT OR ANY FURTHER TREATMENT DECISIONS MADE BY THE SURGEON. A MAXIMUM VOLUME OF 1 / 1.5 CC OF CEMENT, CERTAINLY FAR LESS THAN 2 CC, WAS INJECTED INTO AN L2. NO LEAKS WERE OBSERVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25223253 ↗