Skip to content

Accu-Chek Combo 05027250001Recalls & reported problems

Roche Diabetes Care GmbH · Accu-Chek Spirit Combo · Class 2

All models of Accu-Chek Combo (3)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Roche Accu-Chek Combo insulin pump has 1,830 adverse event reports on record, with no deaths and 130 injuries. Many reports describe inaccurate insulin delivery, buttons that stop working, the pump shutting off without an alert, and a hard-to-read display, and many patients reported high blood sugar. There were no reports in the last 12 months, compared with 71 in the year before. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
1,830
Deaths reported
0
Injuries reported
130
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1,830 adverse event reports that list this exact device (DI 04015630880119), received between Apr 4, 2016 and Mar 4, 2025 — classified as 130 injuries, 1,700 malfunctions.

The most frequently reported specific device problem is “Inaccurate Delivery” (522 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 35 reportsDec 2023: 28 reportsJan 2024: 45 reportsFeb 2024: 29 reportsMar 2024: 27 reportsApr 2024: 25 reportsMay 2024: 25 reportsJun 2024: 12 reportsJul 2024: 28 reportsAug 2024: 25 reportsSep 2024: 34 reportsOct 2024: 32 reportsNov 2024: 20 reportsDec 2024: 17 reportsJan 2025: 23 reportsFeb 2025: 10 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202645
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Inaccurate Delivery522
  • Inadequate User Interface514
  • Fail-Safe Did Not Operate383
  • Display Difficult to Read226
  • Key or Button Unresponsive/not Working87
  • Protective Measures Problem39
  • Display or Visual Feedback Problem22
  • Adverse Event Without Identified Device or Use Problem17

Patient problems

  • No Clinical Signs, Symptoms or Conditions1,197
  • Hyperglycemia515
  • No Consequences Or Impact To Patient53
  • Elevated Ketones/ Diabetic Ketoacidosis47
  • Hypoglycemia37
  • Vomiting14
  • No Known Impact Or Consequence To Patient13
  • Headache7

Recent adverse event reports

The 25 most recent of 1,830 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 4, 2025Key or Button Unresponsive/not Working; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT A BUTTON ON THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21512276 ↗
  • MalfunctionFeb 27, 2025Protective Measures Problem; Protective Measures Problem

    IT WAS REPORTED THAT THE INFUSION DEVICE SHUT OFF WITHOUT FIRST PROVIDING AN ERROR OR ALERT MESSAGE.

    Patient problems: Hyperglycemia

    MAUDE report 21482306 ↗
  • MalfunctionFeb 27, 2025Key or Button Unresponsive/not Working; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT TWO BUTTONS ON THE INFUSION DEVICE WERE DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21482255 ↗
  • MalfunctionFeb 27, 2025Key or Button Unresponsive/not Working; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT A BUTTON ON THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21482234 ↗
  • MalfunctionFeb 24, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN. THIS RESULTED IN LOW BLOOD GLUCOSE VALUES OF 48 MG/DL AND ONE DAY LATER IN ELEVATED BLOOD GLUCOSE LEVELS OF 250 MG/DL.

    Patient problems: Hyperglycemia; Hypoglycemia

    MAUDE report 21444814 ↗
  • InjuryFeb 21, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS. ON THE INCIDENT DAY, THE PATIENT WAS ADMITTED TO HOSPITAL DUE TO HIGH BLOOD GLUCOSE LEVELS WHILE USING THE INFUSION DEVICE. UPON ADMISSION TO HOSPITAL, A BLOOD GLUCOSE TEST RESULTED IN 600 MG/DL. THE PATIENT EXPERIENCED SYMPTOMS LIKE TINGLING IN THE LEGS AND DIZZINESS. WHILE BEING IN HOSPITAL, THE PATIENT USED A HOSPITAL INSULIN PUMP. THE PATIENT WAS RELEASED AFTER ONE DAY.

    Patient problems: Dizziness; Hyperglycemia

    MAUDE report 21437545 ↗
  • MalfunctionFeb 18, 2025Protective Measures Problem; Protective Measures Problem

    IT WAS REPORTED THAT THE INFUSION DEVICE FAILED TO PROVIDE A MECHANICAL ERROR AND/OR CARTRIDGE ERROR OR ALERT MESSAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21398993 ↗
  • MalfunctionFeb 13, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS.

    Patient problems: Hyperglycemia

    MAUDE report 21374415 ↗
  • MalfunctionFeb 12, 2025Display or Visual Feedback Problem; Display or Visual Feedback Problem

    IT WAS REPORTED THAT THE DISPLAY OF THE INFUSION DEVICE WAS DEFECTIVE. THERE WAS A BLACK STAIN ON THE DISPLAY AND THE INFORMATION DISPLAYED WAS BLURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21361812 ↗
  • MalfunctionFeb 7, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS.

    Patient problems: Hyperglycemia

    MAUDE report 21332845 ↗
  • MalfunctionFeb 4, 2025Key or Button Unresponsive/not Working; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT A BUTTON ON THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21303752 ↗
  • MalfunctionJan 31, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS OF 400 MG/DL.

    Patient problems: Hyperglycemia

    MAUDE report 21285102 ↗
  • MalfunctionJan 31, 2025Protective Measures Problem; Protective Measures Problem

    IT WAS REPORTED THAT THE INFUSION DEVICE SHUT OFF WITHOUT FIRST PROVIDING AN ERROR OR ALERT MESSAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21284385 ↗
  • MalfunctionJan 31, 2025Protective Measures Problem; Protective Measures Problem

    IT WAS REPORTED THAT THE INFUSION DEVICE SHUT OFF WITHOUT FIRST PROVIDING AN ERROR OR ALERT MESSAGE SEVERAL TIMES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21281811 ↗
  • MalfunctionJan 30, 2025Display or Visual Feedback Problem; Display or Visual Feedback Problem

    IT WAS REPORTED THAT THE DISPLAY OF THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21275722 ↗
  • MalfunctionJan 29, 2025Display or Visual Feedback Problem; Display or Visual Feedback Problem

    IT WAS REPORTED THAT THE DISPLAY OF THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21263898 ↗
  • MalfunctionJan 29, 2025Key or Button Unresponsive/not Working; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT A BUTTON ON THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21262613 ↗
  • MalfunctionJan 28, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS 35 MMOL/L.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21250868 ↗
  • MalfunctionJan 28, 2025Protective Measures Problem; Protective Measures Problem

    IT WAS REPORTED THAT THE INFUSION DEVICE SHUT OFF WITHOUT FIRST PROVIDING AN ERROR OR ALERT MESSAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21250229 ↗
  • MalfunctionJan 27, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS OF 25 MMOL/L.

    Patient problems: Hyperglycemia

    MAUDE report 21245875 ↗
  • MalfunctionJan 27, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS.

    Patient problems: Hyperglycemia

    MAUDE report 21241678 ↗
  • MalfunctionJan 23, 2025Protective Measures Problem; Protective Measures Problem

    IT WAS REPORTED THAT THE INFUSION DEVICE SHUT OFF WITHOUT FIRST PROVIDING AN ERROR OR ALERT MESSAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21218718 ↗
  • MalfunctionJan 22, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS.

    Patient problems: Hyperglycemia

    MAUDE report 21207547 ↗
  • MalfunctionJan 17, 2025Key or Button Unresponsive/not Working; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT A BUTTON ON THE INFUSION DEVICE WAS DEFECTIVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21177149 ↗
  • MalfunctionJan 17, 2025Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT THE INFUSION DEVICE WAS DELIVERING AN INACCURATE AMOUNT OF INSULIN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21177102 ↗

Other Pump, Infusion, Insulin devices

All Pump, Infusion, Insulin devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page