Accu-Chek Spirit Cartridge 04949935001Recalls & reported problems

Roche Diabetes Care GmbH · Accu-Chek Spirit 3.15ml Cart. Sys. 5pcs · Class 2

All models of Accu-Chek Spirit Cartridge (2)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Accu-Chek Spirit insulin cartridge holds insulin for an insulin pump. Reports mostly describe insulin leaking into the pump's cartridge compartment, with some mentioning high blood sugar and a hospital stay after high then low blood sugar. There are 69 reports that name its identifier, with no deaths and 4 injuries. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
69
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 69 adverse event reports that list this exact device (DI 04015630882755), received between Sep 12, 2019 and Jul 17, 2024 — classified as 4 injuries, 65 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (68 reports).

1 other recall cover devices cleared under the same FDA submission (K042887); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 2 reportsDec 2023: 2 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 2 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak68
  • Infusion or Flow Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions31
  • No Consequences Or Impact To Patient24
  • Hyperglycemia9
  • No Known Impact Or Consequence To Patient4
  • Elevated Ketones/ Diabetic Ketoacidosis1
  • Hypoglycemia1

Recent adverse event reports

The 25 most recent of 69 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 17, 2024Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT INSULIN LEAKED INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS.

    Patient problems: Hyperglycemia

    MAUDE report 19761492 ↗
  • InjuryJul 16, 2024Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT INSULIN WAS LEAKING FROM THE INSULIN CARTRIDGE INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE. THE PATIENT SUFFERED FROM HYPERGLYCEMIA, ADMINISTERED TOO MUCH INSULIN AND WENT INTO HYPOGLYCEMIA. THE EXACT BLOOD GLUCOSE VALUES ARE NOT KNOWN. THE USER WAS TAKEN TO HOSPITAL AND HOSPITALIZED FOR FOUR DAYS. THE PATIENT'S DOCTOR CITED THE PUMP AS THE CAUSE OF THE LEAKAGE. THE TREATMENT ADMINISTERED AT THE HOSPITAL IS UNKNOWN.

    Patient problems: Hyperglycemia; Hypoglycemia

    MAUDE report 19749718 ↗
  • MalfunctionJun 4, 2024Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19459391 ↗
  • MalfunctionApr 16, 2024Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19116221 ↗
  • MalfunctionApr 8, 2024Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN BETWEEN THE CARTRIDGE AND THE ADAPTER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19059350 ↗
  • MalfunctionMar 4, 2024Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18832668 ↗
  • MalfunctionDec 20, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18364924 ↗
  • MalfunctionDec 11, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18301888 ↗
  • MalfunctionNov 8, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE. THE USER ALLEGED THAT A LEAKAGE OCCURRED WITH TWO CARTRIDGES FROM THE SAME BOX/LOT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18094172 ↗
  • MalfunctionNov 7, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN AT THE PLUNGER DURING THE FILLING PROCESS. THIS ISSUE OCCURRED WITH 21 CARTRIDGES FROM THE SAME LOT NUMBER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18082822 ↗
  • MalfunctionOct 27, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18022314 ↗
  • MalfunctionSep 20, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS. THIS ISSUE OCCURRED WITH 5 INSULIN CARTRIDGES FROM THE SAME LOT NUMBER.

    Patient problems: Hyperglycemia

    MAUDE report 17784063 ↗
  • MalfunctionJul 12, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE WAS LEAKY. THE LEAKAGE WAS OBSERVED AT THE CONNECTION BETWEEN THE CARTRIDGE AND THE ADAPTER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17305970 ↗
  • MalfunctionJun 1, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE WAS LEAKING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17036318 ↗
  • MalfunctionApr 5, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16680244 ↗
  • InjuryFeb 3, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE RESULTING IN ELEVATED BLOOD GLUCOSE LEVELS. THE BLOOD GLUCOSE RESULTS WERE NOT PROVIDED. THE PATIENT WAS ADMITTED INTO THE HOSPITAL. THE TYPE OF TREATMENT PROVIDED TO THE PATIENT AT THE HOSPITAL WAS NOT PROVIDED. IT IS UNKNOWN HOW LONG THE PATIENT WAS IN THE HOSPITAL.

    Patient problems: Hyperglycemia

    MAUDE report 16296050 ↗
  • MalfunctionNov 21, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15837192 ↗
  • MalfunctionOct 10, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15572162 ↗
  • MalfunctionAug 30, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15324671 ↗
  • MalfunctionJul 28, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE. THE LEAKAGE WAS OBSERVED AT THE CONNECTION BETWEEN THE CARTRIDGE AND THE INFUSION SET.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15122924 ↗
  • MalfunctionJun 28, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14844177 ↗
  • MalfunctionJun 7, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14620102 ↗
  • MalfunctionMay 16, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE PISTON ROD OF THE INFUSION DEVICE WAS WET AS IF INSULIN LEAKED FROM THE CARTRIDGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14408910 ↗
  • MalfunctionMay 5, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THERE IS AN INSULIN LEAKAGE BETWEEN THE CARTRIDGE AND INFUSION TUBING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14289732 ↗
  • MalfunctionApr 1, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT THE INSULIN CARTRIDGE LEAKED INSULIN INTO THE CARTRIDGE COMPARTMENT OF THE INFUSION DEVICE.

    Patient problems: Hyperglycemia

    MAUDE report 13978583 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K042887. One submission often covers many models, so check the product and lot details in each record.

  • Z-1734-2015 · Apr 22, 2015 · Terminated
    AccuChek Spirit insulin infusion pump.

Other Pump, Infusion, Insulin devices

All Pump, Infusion, Insulin devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page