Bilirubin Direct Gen.2 (Doumas standardization) 05589061190Recalls & reported problems
Roche Diagnostics GmbH · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04015630927531), received between May 27, 2025 and Jan 30, 2026 — classified as 3 malfunctions.
The most frequently reported specific device problem is “High Test Results” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- High Test Results3
- Non Reproducible Results3
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 30, 2026High Test Results; Non Reproducible Results
THERE WAS AN ALLEGATION OF QUESTIONABLE BILIRUBIN DIRECT GEN.2 RESULTS FROM THE COBAS 6000 C 501 ANALYZER. THE INITIAL RESULT WAS 0.5 MG/DL. THE REPEAT RESULT WAS 0.15 MG/DL AND WAS BELIEVED TO BE CORRECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24223662 ↗MalfunctionAug 25, 2025High Test Results; Non Reproducible Results; High Test Results; Non Reproducible Results
THERE WAS AN ALLEGATION OF QUESTIONABLE BILIRUBIN DIRECT GEN.2 RESULTS FOR 2 PATIENT SAMPLES ON A COBAS 4000 C311 STAND ALONE SYSTEM. ON (B)(6) 2025, SAMPLE 1 HAD AN INITIAL DIRECT BILIRUBIN RESULT OF 1.605 MG/DL. THE SAMPLE WAS REPEATED, AND THE RESULT WAS 1.639 MG/DL. THE DOCTOR QUESTIONED THE RESULT. THE REPEAT RESULT FROM AN EXTERNAL LABORATORY THAT USES AN ABBOTT ANALYZER WAS 0.46 MG/DL. THIS REPEAT RESULT WAS DEEMED CORRECT. ON (B)(6) 2025, SAMPLE 2 HAD AN INITIAL DIRECT BILIRUBIN RESULT OF 1.969 MG/DL. THE REPEAT RESULT FROM THE EXTERNAL LABORATORY WAS 0.56 MG/DL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22883103 ↗MalfunctionMay 27, 2025High Test Results; Non Reproducible Results; High Test Results; Non Reproducible Results
THERE WAS AN ALLEGATION OF A QUESTIONABLE BILIRUBIN DIRECT GEN.2 RESULT FROM THE COBAS 4000 C311 STAND ALONE SYSTEM. THE INITIAL RESULT WAS 1.025 MG/DL. THE PEDIATRICIAN REQUESTED A NEW BLOOD SAMPLE TO BE ANALYZED AT ANOTHER LABORATORY USING AN ABBOTT ANALYZER. THE RESULT FOR THE NEW SAMPLE WAS 0.50 MG/DL TWICE. ON (B)(6) 2025, THE INITIAL SAMPLE WAS RETESTED ON THE COBAS C311 ANALYZER, AND THE RESULT WAS 1.158 MG/DL. THE SAME INITIAL SAMPLE WAS SENT TO ANOTHER LABORATORY THAT USES AN ABBOTT ANALYZER, AND THE RESULT WAS 0.52 MG/DL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22087186 ↗
FDA clearance and classification
Cleared through 510(k) K123965 on Feb 28, 2013 (decision: Substantially Equivalent). Submitted by Roche Diagnostics as “Cobas Integra Bilirubin Direct Gen.2”. The FDA review took 64 days. FDA record ↗
The FDA regulates product code CIG (diazo colorimetry, bilirubin) under 21 CFR 862.1110 as a Class II device. 21 CFR 862.1110 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Bilirubin Direct Gen.2 (Doumas standardization) 05589061190
Has the Bilirubin Direct Gen.2 (Doumas standardization) 05589061190 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04015630927531), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Bilirubin Direct Gen.2 (Doumas standardization) 05589061190?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between May 27, 2025 and Jan 30, 2026. In those reports, the most common specific device problems are “High Test Results” (3) and “Non Reproducible Results” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Bilirubin Direct Gen.2 (Doumas standardization) 05589061190?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Bilirubin Direct Gen.2 (Doumas standardization) 05589061190 FDA approved?
It was cleared through 510(k) K123965 on Feb 28, 2013. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Bilirubin Direct Gen.2 (Doumas standardization) 05589061190, and is it still sold?
The FDA's device database lists Roche Diagnostics GmbH as the company responsible for it (brand Bilirubin Direct Gen.2 (Doumas standardization), model 05589061190). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other DIAZO COLORIMETRY, BILIRUBIN devices
- Dimension® Flex® reagent cartridge TBI 10444957Siemens Healthcare Diagnostics Inc. · DIAZO COLORIMETRY, BILIRUBIN2 recalls4 reports
- Dimension Vista® Flex® reagent cartridge TBIL 10445146Siemens Healthcare Diagnostics Inc. · DIAZO COLORIMETRY, BILIRUBIN1 recall7 reports
- VITROS 8383051Ortho-Clinical Diagnostics, Inc. · DIAZO COLORIMETRY, BILIRUBIN1 recall5 reports
- VITROS 1612365Ortho-Clinical Diagnostics, Inc. · DIAZO COLORIMETRY, BILIRUBIN1 recall1 report
- ARCHITECT 6L45-21Abbott Laboratories · DIAZO COLORIMETRY, BILIRUBIN46 reports
- ARCHITECT 6L45-22Abbott GmbH · DIAZO COLORIMETRY, BILIRUBIN30 reports
- ARCHITECT 6L45-41Abbott Laboratories · DIAZO COLORIMETRY, BILIRUBIN18 reports
- Bilirubin Total Gen3 5795397190Roche Diagnostics GmbH · DIAZO COLORIMETRY, BILIRUBIN16 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page