Skip to content

HDL-Cholesterol Gen.4 07528566190Recalls & reported problems

Roche Diagnostics GmbH · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04015630942565), received between Mar 14, 2022 and Apr 1, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “High Test Results” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • High Test Results2
  • Non Reproducible Results2
  • Incorrect Measurement1
  • Insufficient Device Problem Information1
  • Low Test Results1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 1, 2026Incorrect Measurement

    THERE WAS AN ALLEGATION OF QUESTIONABLE RESULTS WITH MULTIPLE ASSAYS FOR A PATIENT SAMPLE TESTED ON THE COBAS INTEGRA 400 PLUS. THIS MEDWATCH WILL APPLY TO THE HDL ASSAY. PLEASE REFER TO THE MEDWATCH WITH A1. PATIENT IDENTIFIER (B)(6) FOR INFORMATION RELATED TO THE LIPASE ASSAY. PLEASE REFER TO THE MEDWATCH WITH A1. PATIENT IDENTIFIER (B)(6) FOR INFORMATION RELATED TO THE CHOLESTEROL ASSAY. PLEASE REFER TO THE MEDWATCH WITH A1. PATIENT IDENTIFIER (B)(6) FOR INFORMATION RELATED TO THE LDL ASSAY. PLEASE REFER TO THE MEDWATCH WITH A1. PATIENT IDENTIFIER (B)(6) FOR INFORMATION RELATED TO THE TRIGLYCERIDES ASSAY. INITIAL RESULTS: LIPASE: 8,859 U/L, CHOLESTEROL: 4,074 MG/DL, HDL: 1,611 MG/DL, LDL: 2,077 MG/DL, TRIGLYCERIDES: 3,133 MG/DL. REPEAT RESULTS: LIPASE: 4,678 U/L, CHOLESTEROL: 167 MG/DL, HDL: 69 MG/DL, LDL: 88 MG/DL, TRIGLYCERIDES: 133 MG/DL. REPEAT RESULTS AFTER A 1:10 MANUAL DILUTION: CHOLESTEROL: 196 MG/DL, HDL: 80 MG/DL, LDL: 101 MG/DL, TRIGLYCERIDES: 154 MG/DL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24756818 ↗
  • MalfunctionNov 11, 2025High Test Results; High Test Results

    WE RECEIVED AN ALLEGATION ABOUT DISCREPANT RESULTS FOR SEVERAL PATIENT SAMPLES TESTED WITH THE HDL-CHOLESTEROL GEN.4 ASSAY ON A COBAS 6000 C501 MODULE. THE REPORTER STATED THAT THE ASSAY RESULTS HAVE BEEN HIGHER THAN NORMAL AND WERE REPEATABLE ON THE SAME INSTRUMENT. THEY NOTED DISCREPANCIES WHEN THE RESULTS WERE COMPARED WITH THE PATIENTS' HISTORICAL DATA. ONE EXAMPLE OF A QUESTIONABLE RESULT WAS PROVIDED: THE INITIAL RESULT WAS 70 MG/DL. THIS RESULT DID NOT MATCH THE PATIENT'S HISTORICAL DATA OF 40 MG/DL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23525834 ↗
  • MalfunctionOct 17, 2023High Test Results; High Test Results

    THE INITIAL REPORTER RECEIVED QUESTIONABLE HDLC4 HDL-CHOLESTEROL PLUS 4TH GENERATION (HDL) RESULT FROM ONE PATIENT SAMPLE TESTED ON THE COBAS 8000 COBAS C 502 MODULE. THE INITIAL RESULT WAS REPORTED OUTSIDE OF THE LABORATORY. THE DOCTOR QUESTIONED THE RESULT WHICH PROMPTED THE RERUN OF THE PATIENT SAMPLE. THE INITIAL RESULT WAS 115 MG/DL. THE REPEAT RESULT WAS 36 MG/DL. THE REPEAT RESULT WAS DEEMED CORRECT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17951424 ↗
  • MalfunctionJul 6, 2023Non Reproducible Results; Non Reproducible Results

    THE INITIAL REPORTER STATED THEY RECEIVED DISCREPANT RESULTS FOR ONE PATIENT SAMPLE TESTED WITH THE CA2 (CALCIUM GEN.2) ASSAY ON A COBAS 8000 COBAS C 502 MODULE. THE SAMPLE INITIALLY RESULTED IN A CA2 VALUE OF 1.269 MMOL/L. A SECOND SAMPLE COLLECTED FROM THE SAME PATIENT WAS TESTED, RESULTING IN A CA2 VALUE OF 2.353 MMOL/L. THE INITIAL SAMPLE WAS THEN REPEATED ON THE SAME AND A SECOND MODULE, RESULTING IN CA2 VALUES OF 2.97 MMOL/L AND 2.254 MMOL/L.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17265638 ↗
  • MalfunctionMar 14, 2022Low Test Results; Insufficient Device Problem Information; Non Reproducible Results; Low Test Results; Insufficient Device Problem Information; Non Reproducible Results

    THE INITIAL REPORTER RECEIVED QUESTIONABLE HDLC4 HDL-CHOLESTEROL PLUS 4TH GENERATION RESULTS FOR MULTIPLE PATIENT SAMPLES WITH A COBAS 6000 C501 MODULE. THE REPORTER STATED THEY WERE RECEIVING VERY LOW RESULTS BUT MOST WERE WITH DATA FLAGS. THEY REPLACED THE REAGENT PACK, CALIBRATION AND QC WERE ACCEPTABLE AND HAD NO FURTHER ISSUES. THE FOLLOWING ARE EXAMPLES OF DISCREPANT RESULTS FOR 7 PATIENT SAMPLES THAT DID NOT HAVE DATA FLAGS: SAMPLE 1: THE INITIAL RESULT WAS 7 MG/DL. THE REPEATED RESULT WAS 37 MG/DL. SAMPLE 2: THE INITIAL RESULT WAS 3 MG/DL. THE REPEATED RESULT WAS 8 MG/DL. THE SECOND REPEATED RESULT WAS 61 MG/DL. SAMPLE 3: THE INITIAL RESULT WAS 3 MG/DL. THE REPEATED RESULT WAS 40 MG/DL. SAMPLE 4: THE INITIAL RESULT WAS 5 MG/DL. THE REPEATED RESULT WAS 45 MG/DL. SAMPLE 5: THE INITIAL RESULT WAS 8 MG/DL. THE REPEATED RESULT WAS 59 MG/DL. SAMPLE 6: THE INITIAL RESULT WAS 7 MG/DL. THE REPEATED RESULT WAS 43 MG/DL. SAMPLE 7: THE INITIAL RESULT WAS 6 MG/DL. THE REPEATED RESULT WAS 42 MG/DL. THE QUESTIONABLE RESULTS WERE REPORTED OUTSIDE OF THE LABORATORY. THE COBAS C501 SERIAL NUMBER WAS (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13756453 ↗

Other LDL & VLDL PRECIPITATION, CHOLESTEROL VIA ESTERASE-OXIDASE, HDL devices

All LDL & VLDL PRECIPITATION, CHOLESTEROL VIA ESTERASE-OXIDASE, HDL devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page