ESSENZ RP150Recalls & reported problems
LivaNova Deutschland GmbH · Class 2
All models of ESSENZ (8)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04033817902997), received between Dec 12, 2023 and Mar 11, 2026 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Pumping Stopped” (4 reports).
1 other recall cover devices cleared under the same FDA submission (K232291); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Pumping Stopped4
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 11, 2026Pumping Stopped
LIVANOVA DEUTSCHLAND RECEIVED A REPORT ABOUT AN ESSENZ HLM THAT SHOWED THE ERROR MESSAGE ¿ART. PUMP ISSUE (2335)¿ RELATED TO THE ARTERIAL PUMP, AND THE PUMP BOX WAS RED WITH A WRENCH. THE ISSUE OCCURRED AFTER THE CASE WAS COMPLETED WITH NO PATIENT IMPACT. AFTER THE ERROR MESSAGE, THE PUMP STOPPED AND THE PERFUSIONIST TRIED TO INCREASE THE RPM OF THE PUMP, BUT IT WOULD NOT TURN. REPORTEDLY, THE PROBLEM WAS SOLVED BY RESTARTING THE HLM; AFTER THAT, THE PUMP WORKED NORMALLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24567235 ↗MalfunctionJan 22, 2026Pumping Stopped
LIVANOVA DEUTSCHLAND RECEIVED A REPORT OF A ROLLER PUMP ASSEMBLED ONTO ESSENZ HEART-LUNG MACHINE (HLM) WHICH SUDDENLY STOPPED DURING PROCEDURE, FOLLOWED BY MULTIPLE ALARMS. CUSTOMER PERFORMED HAND-CRACK AND CONCLUDED THE CASE WITHOUT ANY FURTHER ISSUE. AFTER THE END OF THE PROCEDURE, THE UNIT WAS MANUALLY CHECKED AND THE ARTERIAL PUMP WAS FOUND PROPERLY FUNCTIONING. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24142362 ↗MalfunctionNov 27, 2024Pumping Stopped; Pumping Stopped
SEE INITIAL REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20797016 ↗MalfunctionDec 12, 2023Pumping Stopped; Pumping Stopped
LIVANOVA DEUTSCHLAND RECEIVED A REPORT THAT, DURING A PRCEDURE, THE ESSENZA RPD150 PUMP DISPLAYED ERROR INDICATING DEVIATION OF THE OBSERVED DIRECTION OF ROTATION FROM THE SET DIRECTION OF ROTATION (E2350) AND STOPPED. AFTER TURNING THE KNOB TO ZERO (0) AND BACK TO INITIAL FLOW THE PUMP STARTED AGAIN. PROCEDURE COULD BE FINISHED. THERE IS NO REPORT OF ANY PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18309614 ↗
FDA clearance and classification
Cleared through Special 510(k) K232291 on Aug 24, 2023 (decision: Substantially Equivalent). Submitted by Livanova Deutschland, GmbH as “Essenz HLM, Essenz ILBM”. The FDA review took 23 days. FDA record ↗
The FDA regulates product code DTQ (console, heart-lung machine, cardiopulmonary bypass) under 21 CFR 870.4220 as a Class II device. 21 CFR 870.4220 ↗
The FDA lists this type of device as life-sustaining or life-supporting.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K232291. One submission often covers many models, so check the product and lot details in each record.
- Z-0571-2025 · Oct 18, 2024 · Open, ClassifiedEssenz HLM (Heart-Lung Machine), REF: 49-00-10, with Software
Common questions about the ESSENZ RP150
Has the ESSENZ RP150 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04033817902997), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the ESSENZ RP150?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Dec 12, 2023 and Mar 11, 2026. In those reports, the most common specific device problem is “Pumping Stopped” (4). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ESSENZ RP150?
None of the reports are classified as deaths, 0 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the ESSENZ RP150 FDA approved?
It was cleared through Special 510(k) K232291 on Aug 24, 2023. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the ESSENZ RP150, and is it still sold?
The FDA's device database lists LivaNova Deutschland GmbH as the company responsible for it (brand ESSENZ, model RP150). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS devices
- Terumo® Advanced Perfusion System 1 801188Terumo Cardiovascular Systems Corporation · Console, Heart-Lung Machine, Cardiopulmonary Bypass3 recalls449 reports
- MAQUET CARDIOHELP CARDIOHELP-iMaquet Cardiopulmonary AG · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS5 recalls2 deaths59 reports
- MAQUET CARDIOHELP CARDIOHELP SystemMaquet Cardiopulmonary AG · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS4 recalls16 deaths99 reports
- Terumo® Advanced Perfusion System 1 816300Terumo Cardiovascular Systems Corporation · Console, Heart-Lung Machine, Cardiopulmonary Bypass298 reports
- Terumo® Advanced Perfusion System 1 801763Terumo Cardiovascular Systems Corporation · Console, Heart-Lung Machine, Cardiopulmonary Bypass1 death230 reports
- Terumo® Advanced Perfusion System 1 816571Terumo Cardiovascular Systems Corporation · Console, Heart-Lung Machine, Cardiopulmonary Bypass228 reports
- ESSENZ HLMLivaNova Deutschland GmbH · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS1 recall1 death111 reports
- Terumo® Advanced Perfusion System 1 5773Terumo Cardiovascular Systems Corporation · Console, Heart-Lung Machine, Cardiopulmonary Bypass1 recall77 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page