Intica Neo 7 HF-T QP DF-1 IS4 ProMRI 429552Recalls & reported problems

BIOTRONIK SE & Co. KG · Class 3 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Intica Neo 7 HF-T is an implanted heart defibrillator with resynchronization (CRT-D), a pacemaker-like device that shocks the heart and coordinates its beating. The 28 reports mostly describe units being removed because of infection around the implant, along with one device that could no longer be read by the programmer, high impedance readings, and a battery reaching end-of-life sooner than expected. Reports mention 1 death and 21 injuries. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
28
Deaths reported
1
Injuries reported
21
Recalls naming it
0

Summary

The FDA's MAUDE database contains 28 adverse event reports that list this exact device (DI 04035479156824), received between Mar 10, 2021 and Apr 16, 2026 — classified as 1 death, 21 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Failure to Interrogate” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 3 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem21
  • Failure to Interrogate3
  • Battery Problem1
  • High impedance1
  • Pacing Problem1
  • Premature Elective Replacement Indicator1

Patient problems

  • Unspecified Infection19
  • No Clinical Signs, Symptoms or Conditions7
  • Sepsis3
  • Ischemia1
  • Pocket Erosion1

Recent adverse event reports

The 25 most recent of 28 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 16, 2026Premature Elective Replacement Indicator

    THIS DEVICE WAS EXPLANTED DUE TO ERI WITH UNEXPECTED BATTERY BEHAVIOR. NO ADVERSE PATIENT EVENTS WERE REPORTED. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24895427 ↗
  • InjuryJan 15, 2026Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 24087008 ↗
  • InjuryDec 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 23704617 ↗
  • MalfunctionAug 29, 2025Failure to Interrogate; Failure to Interrogate

    CLINICIAN REPORTED AN INABILITY TO INTERROGATE THE DEVICE. A FORCED INTERROGATION ATTEMPT RESULTED IN THE ERROR MESSAGE: UNABLE TO IDENTIFY DEVICE TYPE. ADDITIONALLY, A FORCED RAM DUMP WAS UNSUCCESSFUL. ALL STANDARD TROUBLESHOOTING PROCEDURES TO ESTABLISH COMMUNICATION WITH THE DEVICE WERE EXHAUSTED. THE DEVICE LAST TRANSMITTED TO HMSC ON JUNE 10, 2025, SHOWING A BATTERY STATUS OF BOS / 100 PERCENT. THE DEVICE REMAINS IMPLANTED. NO ADVERSE PATIENT EVENTS WERE REPORTED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22921955 ↗
  • InjuryAug 25, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 22887919 ↗
  • InjuryAug 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 22843263 ↗
  • InjuryJul 25, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 22621095 ↗
  • InjuryJul 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THIS SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 22461377 ↗
  • InjuryMar 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 21607978 ↗
  • InjuryAug 14, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 19986683 ↗
  • InjuryJan 24, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THIS SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 18574510 ↗
  • MalfunctionJan 5, 2024Failure to Interrogate; Failure to Interrogate

    THIS DEVICE WAS EXPLANTED BECAUSE IT COULD NOT BE INTERROGATED FOLLOWING EXTERNAL SHOCK DURING AN ABLATION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18450373 ↗
  • InjuryOct 25, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 18003277 ↗
  • InjurySep 29, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM EXPLANTED DUE TO INFECTION, VEGETATION AND SEPSIS. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Sepsis; Unspecified Infection

    MAUDE report 17843168 ↗
  • InjurySep 25, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM EXPLANTED DUE TO INFECTION/SEPSIS. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Sepsis; Unspecified Infection

    MAUDE report 17814640 ↗
  • InjurySep 13, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT RECENTLY ADMITTED DUE TO INFECTION. DEVICE AND LEADS ARE STILL IMPLANTED. PATIENT AND HER MEDICAL TEAM ARE CURRENTLY DISCUSSING NEXT STEPS INCLUDING POSSIBLE EXPLANATION. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 17735792 ↗
  • MalfunctionJan 5, 2023High impedance; High impedance

    THIS DEVICE WAS EXPLANTED DUE TO HIGH LV LEAD IMPEDANCES THROUGH DEVICE, THEN NORMAL THROUGH PSA AFTER MULTIPLE ATTEMPTS. NO ADVERSE PATIENT EVENTS WERE REPORTED. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16103761 ↗
  • MalfunctionNov 17, 2022Battery Problem; Battery Problem

    THIS DEVICE SHOWS UNEXPECTED BATTERY BEHAVIOR SEVERAL HOURS AFTER IMPLANT. DEVICE REMAINS IMPLANTED. NO ADVERSE PATIENT EVENTS WERE REPORTED. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15815303 ↗
  • InjurySep 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THIS SYSTEM WAS EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 15417322 ↗
  • InjurySep 1, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SYSTEM EXPLANTED DUE TO INFECTION. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Unspecified Infection

    MAUDE report 15341809 ↗
  • MalfunctionJul 11, 2022Pacing Problem; Pacing Problem

    DEVICE WAS EXPLANTED DUE TO INAPPROPRIATE RAPID ATRIAL PACING. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14976737 ↗
  • DeathJun 24, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT SUFFERED FROM RECURRENT FALL. THE PATIENT WAS HOSPITALIZED. BLOOD TEST AND BLOOD CULTURES WERE DONE. STAPHYLOCOCCUS AUREUS INFECTION WAS SEEN IN THE BLOOD CULTURES. THE DEVICE WAS REPROGRAMMED (DEACTIVATED) AND REMAINS IMPLANTED. THE PATIENT DIED IN THE HOSPITAL. MULTIORGAN FAILURE DUE TO SEPSIS HAS BEEN PROVIDED AS A CAUSE OF DEATH.

    Patient problems: Sepsis; Unspecified Infection

    MAUDE report 14804382 ↗
  • InjuryMay 11, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT SUFFERED FROM DISORDER OF CONSCIOUSNESS, MOTOR RESTLESSNESS BUT DID NOT MOVE THE LEFT LIMBS, MOMENTUM GRADUALLY APPEARED. TRANSIENT ISCHEMIC ATTACK WAS GIVEN AS THE CARDIOVASCULAR CAUSE. PATIENT WAS HOSPITALIZED AND BRAIN CT WAS DONE FOR DIAGNOSTICS. NO DEVICE INVOLVEMENT WAS REPORTED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THIS FILE WILL BE UPDATED.

    Patient problems: Ischemia

    MAUDE report 14361790 ↗
  • InjuryApr 15, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THIS SYSTEM WAS EXPLANTED DUE TO EROSION. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: Pocket Erosion

    MAUDE report 14117860 ↗
  • MalfunctionSep 28, 2021Failure to Interrogate; Failure to Interrogate

    IT WAS REPORTED THAT THIS DEVICE COULD NOT BE INTERROGATED FOLLOWING IMPLANTATION OF HEART MATE III LVAD. MULTIPLE ATTEMPTS WERE MADE WITH DIFFERENT COMBINATIONS OF PGH AND RF, BUT DEVICE WAS NOT ABLE TO BE INTERROGATED. PATIENT WILL BE TRANSFERRED TO A DIFFERENT ROOM AND THE REP WILL ATTEMPT INTERROGATION AGAIN. NO ADVERSE PATIENT EVENTS WERE REPORTED. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, THIS FILE WILL BE UPDATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12544479 ↗

Other Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices

All Defibrillator, automatic implantable cardioverter, with cardiac resynchronization (CRT-D) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page