Skip to content

n.a. 27050VLRecalls & reported problems

Karl Storz GmbH & Co. KG · LASER Working Insert, · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04048551232965), received between Jan 8, 2025 and Jan 8, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Detachment of Device or Device Component1
  • Device Handling Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 8, 2025Break; Detachment of Device or Device Component; Device Handling Problem; Break; Detachment of Device or Device Component; Device Handling Problem

    IT WAS REPORTED THAT A RESECTOSCOPE HAS BEING USED WITH GREEN LIGHT LASER VIA COMPATIBLE LASER WORKING INSERT 27050VL. THE SURGEON FIRED LASER WHILE INSIDE THE SHEATH RESULTING IN THE INNER SHEATH BREAKING OFF - THE CERAMIC BEAK BROKE OFF INSIDE. THE VISIBLE BROKEN PARTS WERE RETRIEVED. THE REMAINING BROKEN PARTS WERE EXPELLED VIA IRRIGATION. THE SURGEON AND TEAM WERE SATISFIED AS THERE WERE NO REMAINING PARTS IN PATIENT.THE SURGERY WAS PROLONGUED FOR LESS THAN 15 MINUTES. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED. CROSS REFEREBCE MDR: 9610617-2025-00005.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21103845 ↗

Other Cystoscope and accessories, flexible/rigid devices

All Cystoscope and accessories, flexible/rigid devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page