E-LINE 86543742Recalls & reported problems
Richard Wolf GmbH · CONNECTING PART RESECTOSCOPE 24FR color code yellow, TL 22mm, rotatable, compatible with 24Fr E-Line sheaths, quick-lock, reusable · Class 2
All models of E-LINE (19)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04055207028049), received between May 17, 2019 and May 17, 2019 — classified as 1 malfunction.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 17, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ON APRIL 19, 2019 THE USER FACILITY REPORTED THE FOLLOWING TO RICHARD WOLF MEDICAL INSTRUMENTS CORPORATION (RWMIC): AN INCIDENT DID OCCUR ON A PATIENT DURING THE CASE. THE CASE FINALLY STARTED 75MINS DELAYED AND THE DOCTOR USED THE WOLF PIRANHA GREEN LIGHT LASER TRAY FOR APPROXIMATELY 1HR 45MINS USING 338,167 JOULES SCOPE SET WORKED EXTREMELY WELL WITH 26FR OUTER SHEATH AND 24FR INNER SHEATH BUT WHEN IT WAS TIME TO SWITCH TO MORCELLATOR PART OF THE CASE THE DOCTOR NOTICE AN OBJECT IN THE BLADDER AND USED A GRASPER TO RETRIEVE THE OBJECT. THE OBJECT WAS A PIECE OF BROKEN OFF DEBRIS FROM THE DISTAL TIP OF THE 24FR INNER LASER SHEATH. THE DOCTORS TECHNIQUE WAS VERY GOOD SO I DID NOT NOTICE ANY MISHANDLING OF THE EQUIPMENT. I NOTIFIED THE OPERATING ROOM CHARGE NURSE, MS. (B)(6) OF THE DAMAGE WHICH OCCURED TO THE WOLF 24FR INNER SHEATH AND THAT THEY WOULD BE LIABLE FOR THE COST OF REPAIR. THE CASE WAS COMPLETED WITHOUT INJURY TO THE PATIENT OR STAFF. WILL THE DEVICE BE RETURNED? YES. WAS THE DEVICE BEING USED DURING A PROCEDURE WHEN THE ISSUE OCCURRED? YES. SPECIFICALLY, WAS THE DEVICE BEING USED ON A PATIENT WHEN THE ISSUE OCCURRED? YES. WAS THERE ANY INJURY OR ILLNESS TO PATIENT OR OT
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8621180 ↗
Other RESECTOSCOPE, WORKING ELEMENT devices
- S-LINE 8680224Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT7 reports
- E-LINE 86553841Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT7 reports
- S-LINE 8680225Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT5 reports
- S-LINE 8680204Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT5 reports
- S-LINE 8680205Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT1 death5 reports
- NA 8654282Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT3 reports
- PRINCESS 8653018Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT2 reports
- SHARK 8674225Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page