E-LINE 86880145Recalls & reported problems
Richard Wolf GmbH · SHEATH RESECTOSCOPE 9FR color code white, SL 106mm, oval, slanted distal end, compatible with attachment 8688264, working element 8688224, and telescopes Ø 1.9mm, 0°, with irrigation stopcock, quick-lock, reusable · Class 2
All models of E-LINE (19)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04055207028575), received between Feb 26, 2021 and Feb 26, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 26, 2021Break; Break
RESULTS OF THE DEVICE EVALUATION REVEALED: THE CUSTOMER REPORTS DAMAGE TO THE PRODUCT THAT OCCURRED DURING USE. THE DAMAGE INVOLVES THE DETACHMENT AND BREAKAGE OF THE INSULATING INSERT (CERAMIC SLEEVE) AT THE DISTAL END OF THE SHAFT OF A 9CH RESECTOSCOPE TYPE 8688.0145. THE INSULATING INSERT COMPLETELY DETACHED FROM THE SHAFT, AS WELL AS A SMALLER FRAGMENT, HAD TO BE RECOVERED FROM THE PATIENT'S URINARY BLADDER BY THE USER. THE INSULATING INSERT, AS WELL AS A SMALLER FRAGMENT, COULD BE SUCCESSFULLY RECOVERED FROM THE PATIENT'S URINARY BLADDER WITH THE AID OF FORCEPS. GRIT OR SMALLER CONCRETIONS WERE DRAINED FROM THE BLADDER VIA AN 8CH BLADDER BALLOON CATHETER AFTER DISCONTINUATION OF THE PROCEDURE. THE PRODUCT IS A SHAFT FOR RESECTOSCOPE 9CH, TYPE NUMBER 8688.0145 FROM LOT 1286350 - RECORDED ON 02/03/2021 WITH CLAIM NUMBER 700015717. THE PRODUCT WAS SHIPPED TO THE CUSTOMER ON 10/21/2015. PLEASE SEE MANUFACTURERS NARRATIVE FOR ADDITIONAL INFORMATION.
Patient problems: Insufficient Information
MAUDE report 11385349 ↗
Other RESECTOSCOPE, WORKING ELEMENT devices
- S-LINE 8680224Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT7 reports
- E-LINE 86553841Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT7 reports
- S-LINE 8680225Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT5 reports
- S-LINE 8680204Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT5 reports
- S-LINE 8680205Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT1 death5 reports
- NA 8654282Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT3 reports
- PRINCESS 8653018Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT2 reports
- SHARK 8674225Richard Wolf GmbH · RESECTOSCOPE, WORKING ELEMENT2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page