Artis zee floor MN 10094142Recalls & reported problems
Siemens Healthcare GmbH · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 2
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
2 FDA recall records name this device's identifier, 2 still open.
12 other recalls cover devices cleared under the same FDA submission (K122644, K141574); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Mar 21, 2024Class IIOpen, Classified
Coolant level in the cooling circuit drops below a certain level, this may result in a situation in which the X-ray tube is no longer sufficiently cooled and the system will display the message TUBE HOT, have a break . the system cannot be operated normally, may result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system
Z-1598-2024 · Root cause: Device Design · Recall details · FDA record ↗
- Feb 23, 2022Class IIOpen, Classified
If the coolant level in the cooling circuit drops below a certain level, this may result in a situation in which the X-ray tube is no longer sufficiently cooled and the system will display the message "TUBE HOT, have a break". Several minutes later the system will block X-ray to prevent further damage and display the message "NO XRAY: TUBE TOO HOT".
Z-0971-2022 · Root cause: Device Design · Recall details · FDA record ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K122644, K141574. One submission often covers many models, so check the product and lot details in each record.
- Z-2526-2018 · May 25, 2018 · TerminatedArtis zee systems with Laird Cooling Unit for SSFD: Material # 7555118. Artis is an angiography system developed for single and biplane diagnostic imaging and interventional proc
- Z-2312-2018 · May 1, 2018 · TerminatedArtis zee floor MN, Material no. 10094142, for angiography and whole body radiographic/fluoroscopic procedures.
- Z-2309-2018 · May 1, 2018 · TerminatedArtis zee biplane MN, Material no. 10094143, for angiography and whole body radiographic/fluoroscopic procedures.
- Z-2314-2018 · May 1, 2018 · TerminatedArtis zeego, Material no. 10280959 , for angiography and whole body radiographic/fluoroscopic procedures.
- Z-2310-2018 · May 1, 2018 · TerminatedArtis zee ceiling, Material no. 10094137, for angiography and whole body radiographic/fluoroscopic procedures.
- Z-2313-2018 · May 1, 2018 · TerminatedArtis zee MP, Material no. 10094139, for angiography and whole body radiographic/fluoroscopic procedures.
- Z-2308-2018 · May 1, 2018 · TerminatedArtis zee biplane, Material no. 10094141, for angiography and whole body radiographic/fluoroscopic procedures.
- Z-2311-2018 · May 1, 2018 · TerminatedArtis zee floor, Material no. 10094135, for angiography and whole body radiographic/fluoroscopic procedures.
- Z-0710-2018 · Sep 28, 2017 · TerminatedArtis zee and Artis zeego model Interventional fluoroscopic x-ray foot switch accessory; Model Numbers: 4787797, 4787805, and 4787813.
- Z-0971-2017 · Dec 8, 2016 · TerminatedArtis zee/zeego, Angiographic x-ray system Stand alone system The Artis systems are a family of dedicated angiography systems developed for single and biplane diagnostic imaging an
- Z-0602-2017 · Nov 1, 2016 · TerminatedArtis zee/zeego, Angiographic x-ray system Product Usage: The Artis systems are a family of dedicated angiography systems developed for single and biplane diagnostic imaging and i
- Z-1846-2015 · May 22, 2015 · TerminatedArtis zee/ zeego systems; Product Usage: Usage: Artis zee/ zeego systems are dedicated angiography systems developed for single and biplane diagnostic imaging and interventional
Other System, x-ray, angiographic devices
- ARTIS icono ceiling 11328100Siemens Healthcare GmbH · System, x-ray, angiographic9 recalls1 report
- Artis Q ceiling 10848281Siemens Healthcare GmbH · System, x-ray, angiographic4 recalls1 death49 reports
- Artis Q floor 10848280Siemens Healthcare GmbH · System, x-ray, angiographic4 recalls18 reports
- Artis zee biplane 10094141Siemens Healthcare GmbH · System, x-ray, angiographic3 recalls63 reports
- Artis Q.zen ceiling 10848354Siemens Healthcare GmbH · System, x-ray, angiographic4 recalls10 reports
- Artis Q.zen floor 10848353Siemens Healthcare GmbH · System, x-ray, angiographic4 recalls5 reports
- iMRX System iMRX System AR-DR MR30RSIMRIS Imaging, Inc. · System, X-Ray, Angiographic1 recall0 reports
- Allia MoveoGe Medical Systems · System, X-Ray, Angiographic1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page