SOMATOM On.site 11369300Recalls & reported problems
Siemens Healthcare GmbH · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04056869263045), received between Jan 25, 2021 and Jan 25, 2021 — classified as 1 death.
The most frequently reported specific device problem is “Poor Quality Image” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Poor Quality Image1
Patient problems
- Cardiac Arrest1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathJan 25, 2021Poor Quality Image; Poor Quality Image
IT WAS REPORTED TO SIEMENS BY THE CUSTOMER USE TEST (CUT) SITE THAT A MALFUNCTION OCCURRED WHILE USING THE SOMATOM ON.SITE SYSTEM. DURING THE EVENING OF JANUARY 13, 2021, A PATIENT WAS ADMITTED TO THE EMERGENCY DEPARTMENT OF ERASMUS MC. THE PATIENT HAD SUFFERED AN OUT OF HOSPITAL CARDIAC ARREST (OHCA) AND WAS IN POOR CONDITION UPON ARRIVAL. THE PATIENT WAS IMMEDIATELY TRANSFERRED TO THE FACILITY INTENSIVE CARE UNIT (ICU) WITHOUT WAITING FOR IMAGING TO BE PERFORMED. LATER THAT SAME EVENING, A REQUEST WAS MADE TO RADIOLOGY TO PERFORM CT BRAIN IMAGING USING THE SOMATOM ON.SITE MOBILE CT (AVAILABLE IN ERASMUS MC AS A PROTOTYPE IN A CUT PHASE) TO AVOID TRANSPORTING THE PATIENT, WHO WAS IN A FRAGILE MEDICAL STATE, TO THE RADIOLOGY DEPARTMENT FOR IMAGING USING A STATIONARY CT SCANNER. THE INDICATION FOR BRAIN IMAGING WAS TO RULE OUT INTRACRANIAL HEMORRHAGE. AN EXPERIENCED CT RADIOGRAPHER WAS AVAILABLE, SO THE ICU AGREED TO THE PERFORMANCE OF THE CT SCAN USING THE REPORTED MOBILE CT. IT WAS ALSO REPORTED THAT THE ICU WAS VERY BUSY DURING THE EVENING OF THE REPORTED EVENT, SO THE STAFF WAS PRESSURED FOR TIME. DURING THE PREPARATION OF THE SCAN, THE RADIOGRAPHER ENCOUNTERED A PROBLEM WITH TH
Patient problems: Cardiac Arrest
MAUDE report 11222680 ↗
Other System, x-ray, tomography, computed devices
- ARTIS icono biplane 11327600Siemens Healthcare GmbH · System, x-ray, tomography, computed15 recalls2 deaths55 reports
- ARTIS icono floor 11327700Siemens Healthcare GmbH · System, x-ray, tomography, computed15 recalls24 reports
- Incisive CTPhilips Healthcare (Suzhou) Co., Ltd. · System, x-ray, tomography, computed13 recalls5 reports
- Spectral CTPhilips Medical Systems Nederland B.V. · System, x-ray, tomography, computed11 recalls3 reports
- Incisive CTPhilips Healthcare (Suzhou) Co., Ltd. · System, X-Ray, Tomography, Computed9 recalls20 reports
- Brilliance iCTPhilips Medical Systems Nederland B.V. · System, x-ray, tomography, computed8 recalls6 reports
- Revolution Apex EliteGE Medical Systems, L.L.C. · System, x-ray, tomography, computed8 recalls0 reports
- Brilliance CT Big BorePhilips Medical Systems Nederland B.V. · System, x-ray, tomography, computed7 recalls1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page