R2P CROSSTELLA RX BD-Q50100ERRecalls & reported problems

Kaneka Corporation · R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm). · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04540778175396), received between Apr 8, 2026 and Apr 8, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Material Fragmentation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 8, 2026Material Fragmentation

    THE DEVICE WAS USED FOR PRE-DILATATION OF A SUPERFICIAL FEMORAL ARTERY (SFA) LESION. AFTER DILATATION OF THE TARGET LESION, RESISTANCE WAS ENCOUNTERED DURING WITHDRAWAL OF THE DEVICE. WHILE CONTINUING THE WITHDRAWAL CAREFULLY, THE DEVICE WAS OBSERVED TO HAVE CAUGHT ON A PREVIOUSLY IMPLANTED STENT LOCATED IN THE COMMON ILIAC ARTERY, AND A SHAFT FRACTURE OF THE DEVICE WAS CONFIRMED. SUBSEQUENTLY, THE LEFT FEMORAL ARTERY WAS PUNCTURED AND A SNARE WAS USED TO RETRIEVE THE FRACTURED PORTION OF THE DEVICE. AFTER RETRIEVAL, NO INTRAVASCULAR RETAINED FRAGMENTS WERE OBSERVED. THE TARGET LESION WAS THEN TREATED USING A DRUG-COATED BALLOON, AND THE PROCEDURE WAS COMPLETED. NO PATIENT INJURY HAS BEEN REPORTED.