VISERA CYSTO-NEPHRO VIDEOSCOPE OLYMPUS CYF TYPE V2R (UDI 04953170287619)Recalls & reported problems

Olympus Medical Systems Corp. · Class 2

All models of VISERA CYSTO-NEPHRO VIDEOSCOPE (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04953170287619), received between Feb 6, 2019 and Mar 17, 2025 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Failure to Clean Adequately1
  • Fluid/Blood Leak1
  • Microbial Contamination of Device1

Patient problems

  • No Patient Involvement2
  • No Clinical Signs, Symptoms or Conditions1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 17, 2025Failure to Clean Adequately; Failure to Clean Adequately

    AN OLYMPUS ENDOSCOPY SUPPORT SPECIALIST (ESS) HAS BEEN DISPATCHED TO OBSERVE THE USER FACILITY¿S REPROCESSING PRACTICES FROM START TO FINISH AND PROVIDE A REPROCESSING IN-SERVICE TRAINING, IF NECESSARY, TO CORRECT AND ADDRESS ANY REPROCESSING DEVIATIONS. WHILE ESS WAS ONSITE WITH THE CUSTOMER AT THE FACILITY THE CUSTOMER STATED THEY HAVE BEEN USING THE SAME RINSE WATER ALL DAY. THE ISSUE WAS OBSERVED DURING REPROCESSING, AND THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21627420 ↗
  • MalfunctionJun 26, 2020Break; Break

    THE USER FACILITY REPORTED THAT PARTS FALL OFF FROM THE DISTAL END OF THE SCOPE. THE SCOPE HAS A HOLE, AND THE ETO CAP WAS BROKEN.

    Patient problems: No Patient Involvement

    MAUDE report 10201296 ↗
  • MalfunctionJun 15, 2020Fluid/Blood Leak; Fluid/Blood Leak

    THE USER FACILITY RETURNED THE DEVICE FOR EVALUATION AND SERVICE DUE TO THE AIR/WATER LEAKAGE OR FLUID INVASION ISSUE. IT WAS ALSO REPORTED THAT THE BENDING SECTION SHEATH OF THE BENDING SECTION BURST OUT, AS THE DEVICE WAS STERILIZED WITHOUT ATTACHING THE SAFETY CAP. OLYMPUS FOLLOWED UP WITH THE USER FACILITY TO OBTAIN ADDITIONAL INFORMATION AND WAS INFORMED THAT THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Patient Involvement

    MAUDE report 10153099 ↗
  • InjuryFeb 6, 2019Microbial Contamination of Device; Microbial Contamination of Device

    OLYMPUS WAS INFORMED THAT A PATIENT TESTED (B)(6) FOR AN UNSPECIFIED INFECTION AFTER UNDERGOING A PROCEDURE. THE PATIENT REPORTEDLY CAME IN WITH A FEVER. THE SCOPE WAS THEN TESTED AND CULTURED (B)(6) FOR AN UNSPECIFIED ORGANISM AFTER REPROCESSING.

    Patient problems: Unspecified Infection

    MAUDE report 8313576 ↗

Other Endoscope, accessories, narrow band spectrum devices

All Endoscope, accessories, narrow band spectrum devices →