COLONOVIDEOSCOPE CF-Q150L (UDI 04953170307638)Recalls & reported problems

Olympus Medical Systems Corp. · Class 2

All models of COLONOVIDEOSCOPE (12)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This Olympus colonoscope is a flexible scope used to look inside the large intestine. Its 154 reports mostly describe trouble cleaning the scope, and some describe blank or poor images. The reports include no deaths and 2 injuries, and 152 are malfunctions. The one recall, started in September 2023, is open and concerns scopes that could be returned from repair with a wet channel. Reports rose from 13 in the year before to 61 in the latest year.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
162
Deaths reported
0
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 162 adverse event reports that list this exact device (DI 04953170307638), received between Dec 20, 2021 and Sep 29, 2026 — classified as 2 injuries, 160 malfunctions.

The most frequently reported specific device problem is “Failure to Clean Adequately” (84 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 4 reportsDec 2023: 4 reportsJan 2024: 3 reportsFeb 2024: 2 reportsMar 2024: 3 reportsApr 2024: 11 reportsMay 2024: 3 reportsJun 2024: 3 reportsJul 2024: 3 reportsAug 2024: 7 reportsSep 2024: 5 reportsOct 2024: 3 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 2 reportsMay 2025: 2 reportsJun 2025: 1 reportsJul 2025: 2 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 6 reportsDec 2025: 3 reportsJan 2026: 3 reportsFeb 2026: 5 reportsMar 2026: 16 reportsApr 2026: 7 reportsMay 2026: 8 reportsJun 2026: 5 reportsJul 2026: 4 reportsAug 2026: 5 reportsSep 2026: 7 reportsOct 2026: 0 reports20242025202616
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Sep 25, 2023Class IIOpen, Classified

    Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection

    Z-0329-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Failure to Clean Adequately84
  • Poor Quality Image17
  • No Display/Image13
  • Contamination9
  • Corroded9
  • Device Reprocessing Problem8
  • Erratic or Intermittent Display7
  • Residue After Decontamination6

Patient problems

  • No Clinical Signs, Symptoms or Conditions159
  • Hemorrhage/Blood Loss/Bleeding1
  • Insufficient Information1
  • Perforation1

Recent adverse event reports

The 25 most recent of 162 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 29, 2026Erratic or Intermittent Display; Poor Quality Image

    The customer returned the colonovideoscope for a separate issue. During the initial evaluation of the returned device, intermittent, distorted and noisy image were observed. No patient involvement.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50937149 ↗
  • MalfunctionSep 24, 2026Poor Quality Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50890078 ↗
  • MalfunctionSep 18, 2026Poor Quality Image

    The customer reported Spotty image during inspection for use involving an Olympus colonovideoscope. There were no reports of patient involvement.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50819621 ↗
  • MalfunctionSep 15, 2026Corroded

    The customer returned the Colonovideoscope for a separate issue. During the initial evaluation of the returned device, corrosion in the Air/Water cylinder was found. No patient involvement.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50777936 ↗
  • MalfunctionSep 11, 2026Failure to Clean Adequately

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50737328 ↗
  • MalfunctionSep 7, 2026Residue After Decontamination

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50658035 ↗
  • MalfunctionSep 2, 2026Poor Quality Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50573399 ↗
  • MalfunctionAug 26, 2026Failure to Clean Adequately

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50456344 ↗
  • MalfunctionAug 20, 2026Poor Quality Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50350258 ↗
  • MalfunctionAug 14, 2026Erratic or Intermittent Display

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50249188 ↗
  • MalfunctionAug 13, 2026Erratic or Intermittent Display

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50238679 ↗
  • MalfunctionAug 11, 2026Corroded

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50216282 ↗
  • MalfunctionJul 31, 2026Erratic or Intermittent Display

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50107361 ↗
  • MalfunctionJul 1, 2026Poor Quality Image

    THE CUSTOMER RETURNED THE COLONOVIDEOSCOPE TO THE SERVICE CENTER FOR EVALUATION OF A SEPARATE ISSUE. DURING TESTING, THE REPAIR CENTER TECHNICIAN FOUND NOISE IMAGE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25680640 ↗
  • MalfunctionJul 1, 2026Failure to Clean Adequately

    THE CUSTOMER RETURNED THE COLONOVIDEOSCOPE¿TO THE SERVICE CENTER FOR EVALUATION RELATED TO A SEPARATE ISSUE. DURING TESTING, THE SERVICE REPAIR TECHNICIAN IDENTIFIED THAT FOREIGN MATERIAL HAD COME OUT OF THE DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25680405 ↗
  • MalfunctionJul 1, 2026Failure to Clean Adequately

    THE CUSTOMER RETURNED THE COLONOVIDEOSCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING DEVICE ANALYSIS THE SERVICE CENTER IDENTIFIED CHANNEL TUBE HAS FOREIGN OBJECTS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25679812 ↗
  • MalfunctionJun 26, 2026Poor Quality Image

    THE CUSTOMER RETURNED THE COLONOVIDEOSCOPE TO THE SERVICE CENTER FOR A BLURRY IMAGE. DURING THE DEVICE ANALYSIS, THE SERVICE CENTER TECHNICIAN INDICATES THAT A NOISY IMAGE WAS FOUND. IT WAS DETERMINED THAT THE CHARGED COUPLED DEVICE UNIT NEEDED TO BE REPLACED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25634800 ↗
  • MalfunctionJun 25, 2026Corroded

    THE CUSTOMER RETURNED THE COLONOSCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE EVALUATION OF THE DEVICE, CORROSION ON SUCTION CYLINDER. THE SERVICE REPAIR TECHNICIAN INDICATED THAT THE MOST LIKELY CAUSE OF THE COMPLAINT WAS TRACED TO COMPONENT FAILURE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25627022 ↗
  • MalfunctionJun 23, 2026Erratic or Intermittent Display

    THE CUSTOMER REPORTED NOISY AND FLICKERING IMAGE DURING DEVICE INSPECTION FOR USE INVOLVING AN OLYMPUS COLONOVIDEOSCOPE. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25597897 ↗
  • MalfunctionJun 23, 2026Corroded

    THE CUSTOMER RETURNED THE COLONOVIDEOSCOPE TO THE SERVICE CENTER FOR EVALUATION RELATED TO A SEPARATE ISSUE. DURING DEVICE EVALUATION, THE REPAIR CENTER TECHNICIAN IDENTIFIED THE DEVICE HAD CORROSION AT LIGHT GUIDE COVER GLASS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25597609 ↗
  • MalfunctionJun 23, 2026Failure to Clean Adequately

    THE CUSTOMER RETURNED THE COLONOVIDEOSCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE DEVICE ANALYSIS, THE SERVICE REPORT TECHNICIAN INDICATES THAT DIRT IN IMAGE FIELD WAS FOUND. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25596500 ↗
  • MalfunctionMay 23, 2026Failure to Clean Adequately

    THE COLONOVIDEOSCOPE WAS RETURNED TO THE SERVICE CENTER WITH A REPORT OF ANGULATION ISSUE. THIS DOES NOT INDICATE AN MDR REPORTABLE EVENT. HOWEVER, MDR REPORTABLE FAILURE WAS FOUND DURING TESTING AT THE SERVICE CENTER. DURING INSPECTION OF THE DEVICE, STICKY SCOPE COVER WAS FOUND. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25265102 ↗
  • MalfunctionMay 23, 2026Poor Quality Image

    THE COLONOVIDEOSCOPE WAS RETURNED TO THE SERVICE CENTER WITH A REPORT OF AIR NOT COMING. THIS DOES NOT INDICATE AN MDR REPORTABLE EVENT. HOWEVER, MDR REPORTABLE FAILURE WAS FOUND DURING TESTING AT THE SERVICE CENTER. DURING INSPECTION OF THE DEVICE, DISTURBED IMAGE WAS FOUND. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25264628 ↗
  • MalfunctionMay 23, 2026No Display/Image

    IT WAS REPORTED THE COLONOVIDEOSCOPE EXHIBITED NO VIDEO OUTPUT AND BLACKOUT IMAGE DURING A COLONOVIDEOSCOPY DIAGNOSTIC PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25264406 ↗
  • MalfunctionMay 21, 2026Residue After Decontamination

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE COLONOVIDEOSCOPE EXHIBITS RESIDUAL FLUID OR FOREIGN MATTER LEAKING FROM THE SCOPE CYLINDER AND FOREIGN OBJECTS IN FORCEPS CHANNEL PORT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25243692 ↗

Other Colonoscope and accessories, flexible/rigid devices

All Colonoscope and accessories, flexible/rigid devices →